Mark J. McLean

Mark J. McLean

Auto-generated profile, based on publicly available information

Mark J. McLean

Materials Measurement Science Division, MML, NIST 4 , Gaithersburg, Maryland 20899

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2024 in Review of Scientific Instruments
Verified
Journal Article
Open access
PDF file
DKDylan J. Kirsch
Dylan J. Kirsch
JMJoshua Martin
Joshua Martin
RWRonald Warzoha
Ronald Warzoha
MMMark McLean
Mark McLean
DWDonald Windover
Donald Windover
ITIchiro Takeuchi
Ichiro Takeuchi
Frequency Domain Thermoreflectance (FDTR) is a versatile technique used to measure the thermal properties of thin films, multilayer stacks, and interfaces that govern the performance and thermal management in semiconductor microelectronics. Reliable thermal property measurements at these length scales (≈10 nm to ≈10 μm), where the physics of thermal transport and phonon scattering at interfaces both grow in complexity, are increasingly relevant as electronic components continue to shrink. While FDTR is a promising technique, FDTR instruments are generally home-built; they can be difficult to construct, align, and maintain, especially for the novice. Our goal here is to provide a practical resource beyond theory that increases the accessibility, replicability, and widespread adoption of FDTR instrumentation. We provide a detailed account of unpublished insights and institutional knowledge that are critical for obtaining accurate and repeatable measurements of thermal properties using FDTR. We discuss component selection and placement, alignment procedures, data collection parameters, common challenges, and our efforts to increase measurement automation. In FDTR, the unknown thermal properties are fit by minimizing the error between the phase lag at each frequency and the multilayer diffusive thermal model solution. For data fitting and uncertainty analysis, we compare common numerical integration methods, and we compare multiple approaches for fitting and uncertainty analysis, including Monte Carlo simulation, to demonstrate their reliability and relative speed. The instrument is validated with substrates of known thermal properties over a wide range of isotropic thermal conductivities, including Borofloat silica, quartz, sapphire, and silicon.

1 February 2018 in Ultramicroscopy
Verified
Journal Article
Closed access
MMMark J. McLean
Mark J. McLean
WOWilliam A. Osborn
William A. Osborn

6 December 2013 in Experimental Mechanics
Verified
Journal Article
Closed access
PDF file
MMM. J. McLean
M. J. McLean
CWC. A. Wade
C. A. Wade
MWM. Watanabe
M. Watanabe
RVR. P. Vinci
R. P. Vinci

4 February 2025 in Journal of Vacuum Science & Technology B
Verified
Journal Article
Closed access
JDJ. Trey Diulus
J. Trey Diulus
CCCarles Corbella
Carles Corbella
FYFeng Yi
Feng Yi
DLDavid LaVan
David LaVan
BKBerc Kalanyan
Berc Kalanyan
Andrei KolmakovAndrei Kolmakov
Andrei Kolmakov
This letter reports on pilot tests of microfabricated nanocalorimeters as a metrology platform for rapid (<40 ms response time) and sensitive (in the range of 1020 m−2 s−1–1017 m−3 for radicals’ flux and density, respectively) detection of neutral radicals generated by reactive cold plasmas. The setup consists of a nanocalorimeter resistive sensor coated with a catalyst alongside an inert reference sensor with identical thermal masses. By measuring the temperature increase in the active sensor caused by radical surface recombination reactions and comparing it to the reference sensor, parasitic stimuli such as IR/visible/UV irradiation and ion- and/or electron-induced heat fluxes can effectively be isolated. The system was successfully tested in a hydrogen plasma environment, and critical performance metrics such as sensitivity and response time were evaluated and benchmarked against the existing plasma radical diagnostic techniques.

1 December 2015 in Journal of Research of the National Institute of Standards and Technology
Verified
Journal Article
Closed access
RGRichard S. Gates
Richard S. Gates
MMMark J. McLean
Mark J. McLean
WOWilliam A. Osborn
William A. Osborn
Laboratory notebooks have been a staple of scientific research for centuries for organizing and documenting ideas and experiments. Modern laboratories are increasingly reliant on electronic data collection and analysis, so it seems inevitable that the digital revolution should come to the ordinary laboratory notebook. The most important aspect of this transition is to make the shift as comfortable and intuitive as possible, so that the creative process that is the hallmark of scientific investigation and engineering achievement is maintained, and ideally enhanced. The smart electronic laboratory notebooks described in this paper represent a paradigm shift from the old pen and paper style notebooks and provide a host of powerful operational and documentation capabilities in an intuitive format that is available anywhere at any time.

1 September 2015 in MRS Communications
Verified
Journal Article
Closed access
PDF file
MMMark J. McLean
Mark J. McLean
WOWilliam A. Osborn
William A. Osborn
RKRebecca Kirkpatrick
Rebecca Kirkpatrick
OBOliver Boomhower
Oliver Boomhower
CKChristopher Keimel
Christopher Keimel
FDFrank W. DelRio
Frank W. DelRio