Muhammadeziz Tursunniyaz

Muhammadeziz Tursunniyaz

Auto-generated profile, based on publicly available information

Muhammadeziz Tursunniyaz

Department of Electrical and Computer Engineering, University of WisconsinMadison, Madison, WI, USA

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 August 2022 in IEEE Sensors Journal
Verified
Journal Article
Closed access
ABAatresha Biswas
Aatresha Biswas
SYShenwei Yin
Shenwei Yin
MTMuhammadeziz Tursunniyaz
Muhammadeziz Tursunniyaz
NKNeda KaramiMohammadi
Neda KaramiMohammadi
JHJingyi Huang
Jingyi Huang
Joseph AndrewsJoseph Andrews
Joseph Andrews
Printing electronics allows us to fabricate low-cost, simple sensor networks. Distributed soil moisture sensors in agriculture industry will result in better water management practices; however, price and reliability do not allow for ubiquitous availability. Here, we demonstrate the fabrication of low-cost, flexible, interdigitated electrode (IDE) soil moisture sensors with the electrode widths of 537, 877, 1055, 1204, and $1916~\mu \text{m}$ on polyimide (PI) substrates using a silver nanoparticle (Ag NP) ink. The sensors were tested in sandy textured soil with a volumetric water content ranging from 0.05 to 0.25 m3/m3. Analytically, the sensitivities of all the sensors are expected to be equal, as the proposed mechanisms dictate that the capacitance should depend linearly on the dielectric constant of the moist soil. However, we found the sensitivity for the widest IDE, which measured $1916~\mu \text{m}$ to be 442 pF/H2O volumetric percentage, whereas the sensitivity for the sensor with 537- $\mu \text{m}$ -wide electrodes to be only 221 pF/H2O volumetric percentage. We hypothesized that the increase in sensitivity can be directly related to the increase in the capacitive fringing field height, which results in increased sensing volume for the widest IDE. The increased sensing volume leads to increased water molecule polarization, increasing the overall capacitance change with respect to changing water content. To validate the hypothesis, we conducted electric fringing field experiments to observe the trend between the maximum fringing field height and the electrode width of an IDE. Results confirmed that increased sensing volume was caused by the increased fringing field height of the electrode in an IDE.

28 November 2022 in Nanoscale
Verified
Journal Article
Closed access
PDF file
MTMuhammadeziz Tursunniyaz
Muhammadeziz Tursunniyaz
VAVasvi Agarwal
Vasvi Agarwal
AMAnna Meredith
Anna Meredith
Joseph AndrewsJoseph Andrews
Joseph Andrews
Flexible resistive temperature sensors with tunable temperature coefficient of resistance and sensitivity fabricated by aerosol jet printing with hybrid nanomaterial inks.

18 August 2022 in IEEE Sensors Journal
Verified
Journal Article
Closed access
MTMuhammadeziz Tursunniyaz
Muhammadeziz Tursunniyaz
Joseph AndrewsJoseph Andrews
Joseph Andrews
The key to fight against a global pandemic such as COVID-19 is to have low-cost, reliable and fast response diagnostic tools. Electronic biosensors are preferred because of their ease of integration into current centralized health care networks and integration with modern point-of-care testing (POCT) devices. Printed electronic sensors provide a sensitive and reliable diagnostic platform to aid in controlling transmissible diseases. In this work, we demonstrate a fully printed capacitive biosensor. The sensor uses coplanar electrodes, coupled with capture antibodies immobilized on microporous Polyvinylidene-fluoride (PVDF) film to detect the SARS-CoV-2 spike protein in spiked buffer solutions. Antibody immobilization on PVDF surface is confirmed with confocal fluorescent imaging microscopy. Gold nanoparticle (GNP) tagged detection antibodies are also introduced to provide increased sensitivity. The gold nanoparticles provide a reflectance layer which leads to increased capacitance. This increased capacitance can be measured directly and has demonstrated the ability to screen for spiked samples with statistical significance. This fully printed capacitive immunoassay has the potential to be used as a transmissible disease screening and vaccine efficacy assessment tool for resource-limited areas.

13 March 2024 in IEEE Sensors Letters
Verified
Journal Article
Closed access
MTMuhammadeziz Tursunniyaz
Muhammadeziz Tursunniyaz
ARAdithya Pillai Ramesh
Adithya Pillai Ramesh
BCBrian Cardwell
Brian Cardwell
Joseph AndrewsJoseph Andrews
Joseph Andrews
Accurate measurement of a variety of different fluid intrinsic physical properties has become increasingly important when attempting to optimize the performance of thermal management systems that utilize aqueous ethylene glycol mixtures as heat transfer media. An ideal sensing system would non-invasively probe the fluid and rapidly ascertain the key physical properties electronically. In this work, we experimentally demonstrate a non-invasive capacitive proximity sensor which is able to deduce temperature and chemical composition simultaneously using radio frequency excitation measurements. The sensor consists of interdigitated co-planar electrodes fabricated using traditional printed circuit board techniques on flexible substrates. An excitation signal is provided to the sensor through a vector network analyzer and the signal reflectance at various frequencies ranging from 1-500 MHz is measured. Based on the signal reflectance (S11), we can distinguish fluid composition, as a function of ethylene glycol content and fluid temperature simultaneously. Interestingly, the position and amplitude of a localized S11 maximum from 360MHz to 420MHz appears to be dependent on both the fluid temperature as well as the composition. We directly observe a shift in the resonant frequency related to the increased dielectric constant caused by the increase in temperature. Simultaneously, we observe a combined frequency shift and S11 magnitude increase due to the dielectric loss factor increase, which is attributed to the increase in ethylene glycol percentage. Ultimately, we demonstrate that a frequencydependent capacitance measurement approach can be utilized for multi-parameter extraction from a single sensor.