Josep Jordana

Josep Jordana

Auto-generated profile, based on publicly available information

Josep Jordana

Department of Electronic Engineering, Castelldefels School of Technology (EPSC), Castelldefels. Spain

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2005 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
Ferran ReverterFerran Reverter
Ferran Reverter
JJJosep Jordana
Josep Jordana
Manel GasullaManel Gasulla
Manel Gasulla
RPRamon Pallàs-Areny
Ramon Pallàs-Areny

1 April 2015 in Sensors and Actuators A: Physical
Verified
Journal Article
Open access
ZKZivko Kokolanski
Zivko Kokolanski
JJJosep Jordana
Josep Jordana
Manel GasullaManel Gasulla
Manel Gasulla
VDVladimir Dimcev
Vladimir Dimcev
Ferran ReverterFerran Reverter
Ferran Reverter
This paper proposes and analyses a microcontroller-based interface circuit for inductive sensors with a variable self-inductance. Besides the microcontroller (mu C) and the sensor, the circuit just requires an external resistor and a reference inductor so that two RL circuits are formed. The mu C appropriately excites such RL circuits in order to measure the discharging time of the voltage across each inductor (i.e. sensing and reference) and then it uses such discharging times to estimate the sensor inductance. Experimental tests using different commercial mu Cs at different clock frequencies show the limitations (especially, due to parasitic resistances and quantisation) and the performance of the proposed circuit when measuring inductances in the millihenry range. A non-linearity error lower than 0.3% full-scale span (FSS) and a resolution of 10 bits are achieved, which are remarkable values considering the simplicity of the circuit. (C) 2015 Elsevier B.V. All rights reserved.Postprint (author's final draft

18 July 2001 in Measurement Science and Technology
Verified
Journal Article
Closed access
PDF file
JJJosep Jordana
Josep Jordana
Manel GasullaManel Gasulla
Manel Gasulla
RPRamon Pallàs-Areny
Ramon Pallàs-Areny

1 February 2006 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
JJJosep Jordana
Josep Jordana
RPRamon Pallàs-Areny
Ramon Pallàs-Areny

1 December 2004 in Review of Scientific Instruments
Verified
Journal Article
Closed access
RPRamon Pallàs-Areny
Ramon Pallàs-Areny
JJJosep Jordana
Josep Jordana
ÓCÓscar Casas
Óscar Casas
Measurement devices and instruments must be calibrated after manufacture to correct for component and assembly tolerances, and periodically to correct for drift and aging effects. The number of reference inputs needed for calibration depends on the actual transfer characteristic and the desired accuracy. Often, a linear characteristic is assumed for simplicity, either for the overall input range (global linearization) or for successive input subranges (piecewise linearization). Thus, only two reference inputs are needed for each straight line. This two-point static calibration can be easily implemented in any system having some basic computation capability and allows for the correction of zero and gain errors, and of their drifts if the system is periodically calibrated. Often, the reference inputs for that calibration are the end values of the measurement range (or subrange). However, this is not always the optimal selection because the calibration error is minimal for those reference inputs only, which are not necessarily the most relevant inputs for the system being considered. This article proposes three optimization criteria for the selection of calibration points: limiting the maximal error (LME), minimizing the integral square error (ISE), and minimizing the integral absolute error (IAE). Each of these criteria needs reference inputs whose values are symmetrical with respect to the midrange input (xc), have the form xc±Δx/(2√n) when the measurand has a uniform probability distribution function, Δx being the measurement span, and do not depend on the nonlinearity of the actual response, provided this is quadratic. The factor n depends on the particular criterion selected: n=2 for LME, n=3 for ISE, and n=4 for IAE. These three criteria give parallel calibration lines and can also be applied to other nonlinear responses by dividing the measurement span into convenient intervals. The application of those criteria to the linearization of a type-J thermocouple illustrate their performance and advantages with respect to the customary end-point linearization (n=1) even for nonquadratic responses. For quadratic responses, n=1 yields the maximal error at the center of the input measurement range.

1 January 1998 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
Manel GasullaManel Gasulla
Manel Gasulla
JJJ. Jordana-Barnils
J. Jordana-Barnils
RPR. Pallas-Areny
R. Pallas-Areny
JTJosep M. Torrents
Josep M. Torrents