Zhengyu Ou

Zhengyu Ou

Auto-generated profile, based on publicly available information

Zhengyu Ou

Department of Mechanical Engineering, Tsinghua University, Beijing, China

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 June 2022 in IEEE Transactions on Magnetics
Verified
Journal Article
Closed access
ZOZhengyu Ou
Zhengyu Ou
ZHZandong Han
Zandong Han
DDDong Du
Dong Du
U-shaped excitation structures are widely used to magnetize steel plates in magnetic flux leakage (MFL) testing. However, the edge effect leads to the difficulty of further increasing the magnetization near the defect as well as the leakage magnetic field (LMF). Therefore, this paper proposes an MFL testing device with a pot-shaped excitation structure to concentrate the main magnetic flux in the steel plate between the two magnetic poles for improving the LMF. First, the simulated comparison of the conventional U-shaped and the proposed pot-shaped structures is presented in the paper. Then, a sensor array is applied to investigate the measured MFL signal components and the C-scan images of the pot-shaped structure. Finally, the experiments are conducted to verify the effectiveness of the simulations and investigate the effect of the relative position of the sensor. The results show that the peak-to-peak value of the MFL signal can increase to 1.93 times after using the pot-shaped structure. Besides, its signal is not affected by the steel plate width and remains the ability to characterize defect sizes and profiles.

1 June 2022 in Review of Scientific Instruments
Verified
Journal Article
Closed access
ZOZhengyu Ou
Zhengyu Ou
ZHZandong Han
Zandong Han
CYChenghao Yang
Chenghao Yang
SDShihao Dong
Shihao Dong
DDDong Du
Dong Du
In magnetic flux leakage (MFL) detection, the identification of surface and back-side defects is required to obtain more accurate defect quantification and risk assessment results. However, current MFL techniques can detect both surface and back-side defects but are generally unable to distinguish between them. Therefore, this paper proposes a new boundary magnetic perturbation (BMP) testing method, combining the results of MFL to distinguish between surface and back-side defects. First, the detection mechanism of the BMP testing method and the impact of the tested magnetic flux density components are presented and analyzed by simulations to further develop an identification method. Then, the influences of the BMP sensor’s lift-off and installation position are investigated by experiments to improve distinguishing performance. Finally, the repeated measurements show that the surface and back-side defects within the wide range of sizes can be identified accurately, even when the defect depths are in the range of 12.5%–87.5% of the sample thickness. Furthermore, the BMP testing method neither increases the length of the detection device nor requires additional magnetizers or signal generators. Therefore, the proposed method is highly suitable for the existing MFL detection devices to distinguish between surface and back-side defects.