6 July 2022 in Joint Diseases and Related Surgery
The aim of this study was to simulate different entry points and investigate potential angulation errors of the intramedullary device and resulting changes in the distal femoral cut using a computer-aided design (CAD) approach. We used a CAD approach to simulate various distal femoral entry points for intramedullary instrumentation. Simulations were performed on (i) a commercially available three-dimensional (3D) CAD model of a human femur (DigitalFemur) and (ii) a digital 3D model of an analogue large femur model produced using a coordinate measuring machine (FaroFemur). Divergent insertion points medial, lateral, anterior and posterior to the ideal position were simulated. Angulation deviations of the resulting positions of the intramedullary rod were measured and changes in the anatomical-mechanical axis angle were calculated. Differences between the two simulation models were quantified. The ideal entry point in the FaroFemur was 9.9 mm anterior and 4.3 mm medial to the apex of the intercondylar notch, and 9.2 mm anterior and 3.6 mm medial in the DigitalFemur. A medial entry point increased the angle between the anatomical femoral axis and the alignment rod in the FaroFemur and DigitalFemur (with 5 mm displacement 2.510° and 2.363°, respectively; with 10 mm displacement 3.239° and 3.283°, respectively). In contrast, a lateral entry point decreased the angle between the anatomical femoral axis and the alignment rod (with 5 mm displacement 2.267° and 2.262°, respectively; with 10 mm displacement 3.158° and 3.731°, respectively). An anterior entry point changed the angle between the anatomical femoral axis and the alignment rod towards extension (1.802° in the FaroFemur; 2.142° in the DigitalFemur), while a posterior entry point generated a deviation toward flexion (2.045° in the FaroFemur; 2.055° in the DigitalFemur). The mean difference between the two models was 0.108±0.121° with the highest difference for anterior displacement. Minor deviations of the entry point for intramedullary instrumentation during total knee arthroplasty can result in malalignment of several degrees.
11 June 2021 in Joint Diseases and Related Surgery
A combination of an anterior sternoclavicular (SC) joint dislocation with a midshaft clavicle fracture is an extremely rare injury. If left untreated, it can lead to severely impaired function of the shoulder with a high risk for complications. A 45-year-old male patient presented with pain and impaired range of motion (ROM) in the left shoulder after a mountain bike crash. Radiographs and a computed tomography scan showed an anterior dislocation of the left SC joint and an ipsilateral midshaft fracture of the clavicle. Open reduction and internal fixation (ORIF) of the clavicle combined with SC joint stabilization using transosseous sutures was performed. Postoperatively, a shoulder-arm bandage was applied with passive motion starting on the first postoperative day. During follow-up, the patient showed an improved clinical function and could return to work after three weeks. Radiographs at eight weeks showed fracture healing without any signs of recurrent SC dislocation. At the final follow-up at 12 weeks, the patient returned to his pre-injury activity level and recreational sports. Despite minimal redislocation in the SC joint, the Constant-Murley Score showed a continuous improvement with 93%, compared to the contralateral side. In conclusion, surgical treatment of anterior SC joint dislocation with a midshaft clavicle fracture can restore shoulder function with no surgery-associated complications.