Gonzalo Jimenez

Gonzalo Jimenez

Auto-generated profile, based on publicly available information

Gonzalo Jimenez

Universidad Politécnica de Madrid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2017 in Annals of Nuclear Energy
Verified
Journal Article
Open access
ELEmma Lopez-Alonso
Emma Lopez-Alonso
DPDavide Papini
Davide Papini
GJGonzalo Jimenez
Gonzalo Jimenez
The evaluation of Passive Autocatalytic Recombiners (PARs) performance has been foreseen from the EU stress tests in the framework of a complementary and comprehensive review of the safety of the Nuclear Power Plants (NPPs). The study presented in this work analyses the size, location and number of the PARs to minimise the risk arising from a hydrogen release and its distribution in the containment building during a hypothetical severe accident. A detailed 3D model of a PWR-KWU containment type was used for the simulations. The numerical tool is the GOTHIC 8.1 containment code, which can model certain aspects of the system geometry and behaviour in more detail than typically considered in containment performance analysis. The severe accident scenario chosen is a fast release of hydrogen-steam mixture from hot leg creep rupture during SBO (Station Black-Out) accident. In the first place, the hydrogen preferential pathways and points of hydrogen accumulation were studied and identified starting from the base case scenario without any mitigation measure. Secondly, a configuration of PARs was simulated under the same conditions of the unmitigated case. The number of PARs\ud considered is 40 units distributed all over the containment building. The PAR configuration offered an improvement in the chosen accidental scenario, decreasing the possibility\ud of hydrogen combustion in all the containment compartments at the end of the transient. The analyses showed that this PAR configuration could lead to a reduction between 30–45% of the final hydrogen concentration. The hydrogen combustion risk is decreased with final hydrogen concentration values\ud below the flammability limit (hydrogen concentration below 7%). Nonetheless, the analysis showed the inability of the PARs to recombine in the early stage of the fast release (the first 1–2 min in this sequence), due to their inertia and occurrence of oxygen starvation conditions

1 November 2019 in Annals of Nuclear Energy
Verified
Journal Article
Closed access
JBJulio Benavides
Julio Benavides
GJGonzalo Jimenez
Gonzalo Jimenez
MGMarta Galbán
Marta Galbán
MLMiriam Lloret
Miriam Lloret

1 January 2016 in Annals of Nuclear Energy
Verified
Journal Article
Closed access
RBRafael Bocanegra
Rafael Bocanegra
GJGonzalo Jimenez
Gonzalo Jimenez
MFMikel Kevin Fernández-Cosials
Mikel Kevin Fernández-Cosials

1 January 2015 in Progress in Nuclear Energy
Verified
Journal Article
Closed access
GJGonzalo Jimenez
Gonzalo Jimenez
JFJose Miguel Flores
Jose Miguel Flores

1 September 2011 in Nuclear Technology
Verified
Journal Article
Open access
CQCésar Queral
César Queral
JGJuan González-Cadelo
Juan González-Cadelo
GJGonzalo Jimenez
Gonzalo Jimenez
EVErnesto Villalba
Ernesto Villalba
Since the Three Mile Island accident, an important focus of pressurized water reactor (PWR) transient analyses has been a small-break loss-of-coolant accident (SBLOCA). In 2002, the discovery of thinning of the vessel head wall at the Davis Besse nuclear power plant reactor indicated the possibility of an SBLOCA in the upper head of the reactor vessel as a result of circumferential cracking of a control rod drive mechanism penetration nozzle—which has cast even greater importance on the study of SBLOCAs. Several experimental tests have been performed at the Large Scale Test Facility to simulate the behavior of a PWR during an upper-head SBLOCA. The last of these tests, Organisation for Economic Co-operation and Development Nuclear Energy Agency Rig of Safety Assessment (OECD/NEA ROSA) Test 6.1, was performed in 2005. This test was simulated with the TRACE 5.0 code, and good agreement with the experimental results was obtained.Additionally, a broad analysis of an upper-head SBLOCA with high-pressur...

1 August 2013 in Annals of Nuclear Energy
Verified
Journal Article
Open access
GJG. Jimenez
G. Jimenez
CQC. Queral
C. Queral
MRM.J. Rebollo-Mena
M.J. Rebollo-Mena
JMJ.C. Martínez-Murillo
J.C. Martínez-Murillo
ELE. Lopez-Alonso
E. Lopez-Alonso
Steam Generator Tube Rupture (SGTR) sequences in Pressurized Water Reactors are known to be one of the most demanding transients for the operating crew. SGTR are a special kind of transient as they could lead to radiological releases without core damage or containment failure, as they can constitute a direct path from the reactor coolant system to the environment.\ud \ud The first methodology used to perform the Deterministic Safety Analysis (DSA) of a SGTR did not credit the operator action for the first 30 min of the transient, assuming that the operating crew was able to stop the primary to secondary leakage within that period of time. However, the different real SGTR accident cases happened in the USA and over the world demonstrated that the operators usually take more than 30 min to stop the leakage in actual sequences. Some methodologies were raised to overcome that fact, considering operator actions from the beginning of the transient, as it is done in Probabilistic Safety Analysis.\ud \ud This paper presents the results of comparing different assumptions regarding the single failure criteria and the operator action taken from the most common methodologies included in the different Deterministic Safety Analysis. One single failure criteria that has not been analysed previously in the literature is proposed and analysed in this paper too. The comparison is done with a PWR Westinghouse three loop model in TRACE code (Almaraz NPP) with best estimate assumptions but including deterministic hypothesis such as single failure criteria or loss of offsite power. The behaviour of the reactor is quite diverse depending on the different assumptions made regarding the operator actions. On the other hand, although there are high conservatisms included in the hypothesis, as the single failure criteria, all the results are quite far from the regulatory limits. In addition, some improvements to the Emergency Operating Procedures to minimize the offsite release from the damaged SG in case of a SGTR are outlined taking into account the offsite dose sensitivity results