Correct operation of the protection system is of vital importance for the reliability and security of supply. Information of protection system faults is therefore important for different purposes such as quality of supply regulation and as input data to security and reliability analysis. This paper provides a comparative review of the Norwegian and Finnish fault statistics for line and transformer protection systems at the voltage levels 132-400 kV for the period 1999-2004. Unwanted operation is the major fault type, particularly for transformer protection. Human causes dominate by roughly 50%, technical faults count for 20-30% while there are large portions of faults where the cause is not identified. In Norway 20% of the total energy not supplied at these voltage levels are caused by the protection. The corresponding portion in Finland is only 4%
1 June 2010 in International Journal of System Assurance Engineering and Management
This paper describes a framework and methodology for risk and vulnerability analysis including extraordinary events in power systems. The framework is based on a bow-tie structure and identifies threats, unwanted events, barriers and consequences. Application of the methodology is shown for a real case analyzing extraordinary events in a transmission system. In this case the consequence is unacceptable, but the risk is moderate due to the low probability for the event to occur. The case study and experience so far indicates that one of the most challenging parts of a risk and vulnerability analysis is how to identify the vulnerable operational states and extraordinary events.
The reliability of protection systems has a considerable effect on the reliability of supply, and hence appropriate protection system reliability models must be incorporated in power system reliability studies. These studies assume increasing prominence, especially in the wake of influx of smart grid technologies, making it imperative to handle the accompanying failure dependencies in detail. This paper presents the results of one such related investigation carried out to incorporate the impact of transmission line failure modes on account of various protection system response scenarios on supply reliability indices. In addition to the basic frequency and duration indices, indices such as annual power interrupted, annual energy not supplied, and annual interruption costs are computed, built on a minimal cut set based approach. The approach presented circumvents the need for complex Markov models to include protection system reliability considerations. An illustrative case study is employed to draw attention to the impact of identified comprehensive failure scenarios in protection and control equipment on power system reliability. Comparisons are made with an existing simplified method, and also with a case where protection system reliability is assumed to be perfect. The results bring forward the emphasis to be placed on initiatives to include the study of impact of reliability of protection systems on reliability of supply.