1 October 2016 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
YNYoshihiko Ninomiya
Yoshihiko Ninomiya
KMKeiichiro Minami
Keiichiro Minami
KMKazunori Miyata
Kazunori Miyata
SEShuichiro Eguchi
Shuichiro Eguchi
RSRie Sato
Rie Sato
TOTetsuro Oshika
Tetsuro Oshika
To assess 1-year clinical results of toric intraocular lenses (IOLs) in eyes having with-the-rule (WTR), against-the-rule (ATR), or oblique corneal astigmatism. Four ophthalmic surgical sites, Japan. Prospective case series. One of 3 toric IOLs or 1 nontoric IOL was implanted in eyes having phacoemulsification and IOL implantation. The study comprised 218 eyes (155 patients). Based on the suggestion of an online toric calculator with anterior corneal curvature data, 63 eyes received the SN6AT3 IOL with a cylinder power of 1.50 diopters [D] at IOL plane (1.50 D cylinder IOL) 55 eyes the SN6AT4 IOL with a cylinder power of 2.25 D at IOL plane (2.25 D cylinder IOL), and 58 eyes the SN6AT5 IOL with a cylinder power of 3.00 D at IOL plane (3.00 D cylinder IOL) (all Acrysof IQ toric), and 42 eyes received the SN60WF IOL (nontoric IOL). One hundred ninety-four eyes (89.0%) completed 1-year of follow-up. The centroid error in predicted residual astigmatism calculated using vector analysis was close to the origin in eyes with WTR astigmatism (0.17 diopter [D] @ 174.9 ± 0.54 D), while those with ATR and oblique astigmatism were significantly shifted toward the ATR direction (P < .001). The distance from the origin was significantly smaller in the WTR group than in ATR and oblique groups (P < .05). The centroid errors were shifted toward ATR in all toric IOL groups (P < .001); however, the distance from the origin was not different between groups (P = .52). Postoperatively, the mean absolute misalignment of the IOLs was 5.92 degrees ± 5.59 (SD) at 1 day and 6.24 ± 5.87 degrees at 1 year. The results of other clinical parameters were excellent, with no significant differences between astigmatism categories or IOL models. Based on anterior corneal curvature alone, toric IOLs undercorrected ATR and oblique astigmatism; however, 1-year clinical results of toric IOLs were highly stable and satisfactory. None of the authors has a financial or proprietary interest in any material or method mentioned.

12 January 2022 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
YNYoshihiko Ninomiya
Yoshihiko Ninomiya
MFMutsumi Fuchihata
Mutsumi Fuchihata
SNSayuri Ninomiya
Sayuri Ninomiya
Vitreous loss is one of the adverse complications that can occur during phacoemulsification. Once vitreous loss is identified, procedural guidelines advise that phacoemulsification be ceased and the probe carefully withdrawn to minimize traction on the vitreous. Bimanual-bipedal technique described in this study holds the phacoemulsification probe in place and inserts the vitrectomy cutter through the pars plana port with the other hand. After removal of vitreous around the phacoemulsification tip, the vitrectomy cutter is switched to a cutting rate of zero. phacoemulsification can then be resumed with the vitrectomy cutter as a retainer of the lens fragments, similar to the hook of bimanual technique. Lens fragments are synergistically retained through aspiration between the vitrectomy cutter and phacoemulsification probe to prevent displacement. The bimanual-bipedal technique may offer a more streamlined and potentially safer approach for phacoemulsification with vitreous loss.

1 June 2026 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
YNYoshihiko Ninomiya
Yoshihiko Ninomiya
YMYayoi Muraguchi
Yayoi Muraguchi
MFMutsumi Fuchihata
Mutsumi Fuchihata
Purpose: To evaluate the effectiveness of astigmatism correction using low-cylinder-power monofocal toric intraocular lenses (IOLs) in eyes with mild corneal astigmatism. Setting: Tertiary care center in Osaka, Japan. Design: Single-center ambispective observational cohort study. Methods: Eyes were categorized into the T2 group (toric IOL with 1.0 diopter [D] cylinder power at the IOL plane), nontoric IOL (T0) group, or Tx group (T3 or higher toric IOLs; ≥1.5 D cylinder power). Eyes with irregular corneal astigmatism or prior ocular surgery were excluded. 3-month outcomes included uncorrected distance visual acuity (UDVA), refractive and subjective astigmatism, and vector analysis. Results: 75 eyes (25 per group, 46 patients) were analyzed. At 3 months, the T2 group showed significantly lower mean refractive astigmatism (0.45 ± 0.25 D) and subjective astigmatism (0.28 ± 0.34 D) than the T0 group (0.92 ± 0.31 D and 0.69 ± 0.33 D; both P = .000), with better UDVA (logMAR −0.05 ± 0.12 vs 0.08 ± 0.15; P = .002). In paired-eye analyses, T0 eyes had greater refractive astigmatism (0.92 ± 0.32 D) and subjective astigmatism (0.69 ± 0.33 D) than their Tx fellow eyes (0.53 ± 0.33 D; P < .001 and 0.39 ± 0.32 D; P = .002). T2 achieved astigmatism correction comparable with that of Tx in mild-astigmatism eyes. Tx eyes trended toward better UDVA than their T0 fellows ( P = .060). Conclusions: Low-cylinder-power toric IOLs effectively corrected astigmatism and improved visual outcomes in eyes with mild corneal astigmatism, a population previously excluded from toric IOL implantation.