Samir Morad

Samir Morad

Auto-generated profile, based on publicly available information

Samir Morad

University of East London University Way

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 August 2017 in Annals of Biomedical Engineering
Verified
Journal Article
Open access
PDF file
GDGiulio Dagnino
Giulio Dagnino
IGIoannis Georgilas
Ioannis Georgilas
SMSamir Morad
Samir Morad
PGPeter Gibbons
Peter Gibbons
PTPayam Tarassoli
Payam Tarassoli
SDSanja Dogramadzi
Sanja Dogramadzi
Complex joint fractures often require an open surgical procedure, which is associated with extensive soft tissue damages and longer hospitalization and rehabilitation time. Percutaneous techniques can potentially mitigate these risks but their application to joint fractures is limited by the current sub-optimal 2D intra-operative imaging (fluoroscopy) and by the high forces involved in the fragment manipulation (due to the presence of soft tissue, e.g., muscles) which might result in fracture malreduction. Integration of robotic assistance and 3D image guidance can potentially overcome these issues. The authors propose an image-guided surgical robotic system for the percutaneous treatment of knee joint fractures, i.e., the robot-assisted fracture surgery (RAFS) system. It allows simultaneous manipulation of two bone fragments, safer robot-bone fixation system, and a traction performing robotic manipulator. This system has led to a novel clinical workflow and has been tested both in laboratory and in clinically relevant cadaveric trials. The RAFS system was tested on 9 cadaver specimens and was able to reduce 7 out of 9 distal femur fractures (T- and Y-shape 33-C1) with acceptable accuracy (≈1 mm, ≈5°), demonstrating its applicability to fix knee joint fractures. This study paved the way to develop novel technologies for percutaneous treatment of complex fractures including hip, ankle, and shoulder, thus representing a step toward minimally-invasive fracture surgeries.

28 May 2016 in International Journal of Computer Assisted Radiology and Surgery
Verified
Journal Article
Open access
PDF file
GDGiulio Dagnino
Giulio Dagnino
IGIoannis Georgilas
Ioannis Georgilas
PKPaul Köhler
Paul Köhler
SMSamir Morad
Samir Morad
RARoger Atkins
Roger Atkins
SDSanja Dogramadzi
Sanja Dogramadzi
Purpose In the surgical treatment for lower-leg intra-articular fractures, the fragments have to be positioned and aligned to reconstruct the fractured bone as precisely as possible, to allow the joint to function correctly again. Standard procedures use 2D radiographs to estimate the desired reduction position of bone fragments. However, optimal correction in a 3D space requires 3D imaging. This paper introduces a new navigation system that uses pre-operative planning based on 3D CT data and intra-operative 3D guidance to virtually reduce lower-limb intra-articular fractures. Physical reduction in the fractures is then performed by our robotic system based on the virtual reduction. Methods 3D models of bone fragments are segmented from CT scan. Fragments are pre-operatively visualized on the screen and virtually manipulated by the surgeon through a dedicated GUI to achieve the virtual reduction in the fracture. Intra-operatively, the actual position of the bone fragments is provided by an optical tracker enabling real-time 3D guidance. The motion commands for the robot connected to the bone fragment are generated, and the fracture physically reduced based on the surgeon’s virtual reduction. To test the system, four femur models were fractured to obtain four different distal femur fracture types. Each one of them was subsequently reduced 20 times by a surgeon using our system. Results The navigation system allowed an orthopaedic surgeon to virtually reduce the fracture with a maximum residual positioning error of \(0.95 \pm 0.3\,\hbox {mm}\) (translational) and \(1.4^{\circ } \pm 0.5^{\circ }\) (rotational). Correspondent physical reductions resulted in an accuracy of 1.03 ± 0.2 mm and \(1.56^{\circ }\pm 0.1^{\circ }\), when the robot reduced the fracture. Conclusions Experimental outcome demonstrates the accuracy and effectiveness of the proposed navigation system, presenting a fracture reduction accuracy of about 1 mm and \(1.5^{\circ }\), and meeting the clinical requirements for distal femur fracture reduction procedures.

4 May 2017 in International Journal of Computer Assisted Radiology and Surgery
Verified
Journal Article
Open access
PDF file
GDGiulio Dagnino
Giulio Dagnino
IGIoannis Georgilas
Ioannis Georgilas
SMSamir Morad
Samir Morad
PGPeter Gibbons
Peter Gibbons
PTPayam Tarassoli
Payam Tarassoli
SDSanja Dogramadzi
Sanja Dogramadzi
Purpose Joint fractures must be accurately reduced minimising soft tissue damages to avoid negative surgical outcomes. To this regard, we have developed the RAFS surgical system, which allows the percutaneous reduction of intra-articular fractures and provides intra-operative real-time 3D image guidance to the surgeon. Earlier experiments showed the effectiveness of the RAFS system on phantoms, but also key issues which precluded its use in a clinical application. This work proposes a redesign of the RAFS’s navigation system overcoming the earlier version’s issues, aiming to move the RAFS system into a surgical environment. Methods The navigation system is improved through an image registration framework allowing the intra-operative registration between pre-operative CT images and intra-operative fluoroscopic images of a fractured bone using a custom-made fiducial marker. The objective of the registration is to estimate the relative pose between a bone fragment and an orthopaedic manipulation pin inserted into it intra-operatively. The actual pose of the bone fragment can be updated in real time using an optical tracker, enabling the image guidance. Results Experiments on phantom and cadavers demonstrated the accuracy and reliability of the registration framework, showing a reduction accuracy (sTRE) of about \(0.88~\pm 0.2\,\hbox {mm}\) (phantom) and \(1.15\pm 0.8\,\hbox {mm}\) (cadavers). Four distal femur fractures were successfully reduced in cadaveric specimens using the improved navigation system and the RAFS system following the new clinical workflow (reduction error \(1.2\pm 0.3\,\hbox {mm}\), \(2\pm 1{^{\circ }})\). Conclusion Experiments showed the feasibility of the image registration framework. It was successfully integrated into the navigation system, allowing the use of the RAFS system in a realistic surgical application.

16 October 2012 in PLOS ONE
Verified
Journal Article
Open access
PDF file
AWAndrew P. S. Wheeler
Andrew P. S. Wheeler
SMSamir Morad
Samir Morad
NBNoor Buchholz
Noor Buchholz
MKMartin Knight
Martin Knight
We develop a new computational model of capillary-waves in free-jet flows, and apply this to the problem of urological diagnosis in this first ever study of the biophysics behind the characteristic shape of the urine stream as it exits the urethral meatus. The computational fluid dynamics model is used to determine the shape of a liquid jet issuing from a non-axisymmetric orifice as it deforms under the action of surface tension. The computational results are verified with experimental modelling of the urine stream. We find that the shape of the stream can be used as an indicator of both the flow rate and orifice geometry. We performed volunteer trials which showed these fundamental correlations are also observed in vivo for male healthy volunteers and patients undergoing treatment for low flow rate. For healthy volunteers, self estimation of the flow shape provided an accurate estimation of peak flow rate ( ). However for the patients, the relationship between shape and flow rate suggested poor meatal opening during voiding. The results show that self measurement of the shape of the urine stream can be a useful diagnostic tool for medical practitioners since it provides a non-invasive method of measuring urine flow rate and urethral dilation.

1 May 2017
Verified
Conference Paper
Open access
GDGiulio Dagnino
Giulio Dagnino
IGIoannis Georgilas
Ioannis Georgilas
SMS. Morad
S. Morad
PGP. Gibbons
P. Gibbons
PTP. Tarassoli
P. Tarassoli
SDS. Dogramadzi
S. Dogramadzi
The integration of minimally invasive robotic assistance and image-guidance can have positive impact on joint fracture surgery, providing a better clinical outcome with respect to the current open procedure. In this paper, a new design of the RAFS surgical system is presented. The redesign of the robotic system and its integration with a novel 3D navigation system through a new clinical workflow, overcomes the drawbacks of the earlier prototype. This makes the RAFS surgical system more suitable to clinical scenarios in the operating theatre. System accuracy and effectiveness are successfully demonstrated through laboratory trials and preliminary cadaveric trials. The experimental results demonstrate that the system allows the surgeon to reduce a 2-fragment distal femur fracture in a cadaveric specimen, with a reduction accuracy of up to 0.85 mm and 2.2°. Preliminary cadaveric trials also provided a positive and favorable outcome pointing to the usability and safety of the RAFS system in the operating theatre, potentially enhancing the capacity of joint fracture surgeries.

1 August 2015
Verified
Conference Paper
Closed access
SMSamir Morad
Samir Morad
CUChristian Ulbricht
Christian Ulbricht
PHPaul Harkin
Paul Harkin
JCJustin Chan
Justin Chan
KPKim Parker
Kim Parker
RVRavi Vaidyanathan
Ravi Vaidyanathan
Surgical removal of cancerous tissue from the spine is limited by the inability of hand held drills and cutting tools to reach small crevices present in complex bones such as the spinal column, especially on the anterior side. In addition, the high speed rotating mechanisms used presently are subject to stability issues when manoeuvring around tortuous bone forms. We report on the design and experimental testing of a novel flexible robotic surgical system which addresses these issues. The robot consists of a flexible probe, a water jet cutting system, and a haptic feedback controller. The water jet cutting system consists of a flexible end effector capable of bending around the anterior of the spinal column for tissue removal. A new experimental method of controlling the depth of water jet cut is described. The haptic feedback controller is based on a constraint set approach to define 3D boundaries, based on five key types of constraints. Experimental outcomes of measuring the depth of water jet cut were combined with haptic regional constraints with the aim of improving the safety of surgical procedures. The reliability, accuracy and performance of the prototype robot were tested in a mock surgical procedure on the lower lumbar vertebrae. Results show promise for the implementation of water jet cutting for robotic surgical spinal procedures.