Zhimin He

Zhimin He

Auto-generated profile, based on publicly available information

Zhimin He

College of Environmental Science and Engineering, Suzhou University of Science and Technology, Suzhou, 215000, China

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 August 2022 in Journal of Environmental Management
Verified
Journal Article
Closed access
ZHZhimin He
Zhimin He
Xiaoyi XuXiaoyi Xu
Xiaoyi Xu
BWBin Wang
Bin Wang
ZLZhenfei Lu
Zhenfei Lu
DSDezhi Shi
Dezhi Shi
WWWei Wu
Wei Wu

1 February 2022 in Chemosphere
Verified
Journal Article
Closed access
Xiaoyi XuXiaoyi Xu
Xiaoyi Xu
ZHZhimin He
Zhimin He
HTHui Tang
Hui Tang
YSYidong Sun
Yidong Sun
SZShuyuan Zhang
Shuyuan Zhang
FJFangying Ji
Fangying Ji

1 January 2022 in SSRN Electronic Journal
Verified
Preprint
Open access
PDF file
ZHZhimin He
Zhimin He
Xiaoyi XuXiaoyi Xu
Xiaoyi Xu
BWBing Wang
Bing Wang
ZLZhenfei Lu
Zhenfei Lu
Dezhi ShiDezhi Shi
Dezhi Shi
WWWei Wu
Wei Wu
Iron-loaded granular activated carbon (Fe-GAC) was prepared, characterized, and its performance as a catalyst in the Fenton oxidation of tetracycline (TC) was compared with that of carbon grains without iron supplementation. The characterization results revealed that the Fe 2+ was successfully introduced onto the original granular activated carbon (GAC) and diversified the surface morphology and elemental compounds of materials. Adsorption tests confirmed that the adsorption of TC on both materials can be described using pseudo-second-order kinetic model and Langmuir isotherm model. The response characteristics and influencing factors of degradation of TC in two systems were evaluated. TC removal over 60min at pH 3 was 89.5% for the GAC/Fenton system and 92.6% for the Fe-GAC/Fenton system.Moreover, the Fe-GAC/Fenton system displayed a lower Fe 2+ dosage than that of GAC/Fenton (an Fe 2+ /H 2 O 2 molar ratio of 0.04:1 versus 0.007:1). Excitation-emission matrix fluorescence spectroscopy showed that Fe-GAC/Fenton system delivered better mineralization, at least with TC. Fourteen intermediates were detected using quadrupole time-of-flight liquid chromatography coupled with mass system, and three possible degradation pathways for TC are proposed. Catalyst regeneration treatments was evaluated over six cycles. The regeneration was 6.5% more effective with the iron-supplemented carbon granules.