Frederik Thørholm Andersen

Frederik Thørholm Andersen

Auto-generated profile, based on publicly available information

Frederik Thørholm Andersen

Department of Cardiothoracic and Vascular Surgery, Aarhus University Hospital, Aarhus N, Denmark

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 October 2024 in Journal of Cardiovascular Translational Research
Verified
Journal Article
Open access
PDF file
JJJohannes H. Jedrzejczyk
Johannes H. Jedrzejczyk
FAFrederik T. Andersen
Frederik T. Andersen
JPJacob Petersen
Jacob Petersen
AKAlexander Emil Kaspersen
Alexander Emil Kaspersen
USUrjosee Sahana
Urjosee Sahana
MTMarcell J. Tjørnild
Marcell J. Tjørnild
To assess the mechanical properties of small intestinal submucosal extracellular matrix (SIS-ECM) iterations and choose the optimal version for evaluating functional geometrics after posterior mitral valve reconstruction. Four SIS-ECM versions (2- and 4-ply vacuum-pressed and lyophilized) underwent uniaxial tensile testing. A posterior mitral valve reconstruction patch was developed based on MRI scans (n = 5). Posterior mitral valve reconstruction using 2-ply vacuum-pressed SIS-ECM was performed (n = 7), and geometrics were evaluated using a modified left heart simulator. The vacuum-pressed iterations displayed superior maximum stress values compared to lyophilized (2-ply: median [IQR], 15.8 [15.2–19.0] vs 7.9 [7.3–8.3] MPa, p < 0.001; 4-ply: median (IQR), 15.8 –[14.6–22.0] vs 7.9 [7.6–8.4] MPa). All reconstructed valves were competent with preserved total leaflet area, but individual leaflet segment areas were redistributed. Posterior mitral valve reconstruction with our 2-ply vacuum-pressed SIS-ECM patch design was feasible in vitro. Further in vivo evaluation is warranted. Graphical Abstract

2 July 2025 in Surgical Endoscopy
Verified
Journal Article
Open access
PDF file
FAFrederik Thørholm Andersen
Frederik Thørholm Andersen
JPJacob Petersen
Jacob Petersen
AKAlexander Emil Kaspersen
Alexander Emil Kaspersen
MPMads Vikkelsø Pedersen
Mads Vikkelsø Pedersen
GSGustav Singer
Gustav Singer
TLTroels Lading
Troels Lading
Background: Indocyanine green fluorescence imaging (ICG-FI) is a novel tool for continuous assessment of tissue perfusion. However, consensus on the optimal methodology is lacking. It was hypothesized that quantitative ICG-FI parameters based on continuous micro-dosing correlate with corresponding transit time flow measurements in the functional renal end artery. This study aimed to examine the feasibility of continuous, quantitative ICG-FI for detecting perfusion changes (hypoperfusion, reperfusion) in porcine kidneys. Methods: Renal perfusion was assessed using continuous, quantitative ICG-FI under controlled renal artery flow adjustments (no, partial, full, partial, and no occlusion) in ten healthy female pigs. Four 0.008 mg/kg ICG micro-doses were administered with 60-s intervals for each flow adjustment. As a reference, simultaneous renal artery transit time flow probe measurements were recorded. ICG-FI parameters were extracted by PerfusionWorks®, providing surrogate markers for perfusion, and correlated to the reference renal artery transit time flow measurements using linear regression modeling. Results: During hypoperfusion, mean flow decreased from 277 to 139 to 0 ml/min in the no, partial, and full occlusion steps, respectively. F ingress (R 2 = 79%), F max (R 2 = 79%), and slope (R 2 = 78%) correlated with flow. During reperfusion, mean flows increased from 0 to 169 to 240 ml/min in the full, partial, and no occlusion steps, respectively, and F ingress (R 2 = 71%), F max (R 2 = 69%), and slope (R 2 = 79%) also correlated with flow. Overall, slope exhibited the strongest correlation (R 2 = 54%). T ingress, T ½max, time ratio, and T max exhibited poor correlations with flow. Conclusion: Continuous assessment of renal perfusion was technically feasible. In this kidney model, the combined ICG-FI parameter, slope, and the intensity-dependent parameters F ingress and F max exhibited convincing correlation with flow, appearing promising for the continuous assessment of tissue perfusion. Time-related parameters did not correlate with flow in this specific model, likely due to the kidney's unique vascular characteristics. Graphical