Department of Pediatrics, Division of Neonatology, Erasmus MC Sophia Children’s Hospital, University Medical Center Rotterdam, Rotterdam, The Netherlands

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 September 2020 in Neonatology
Verified
Journal Article
Open access
PDF file
WWWillem van Weteringen
Willem van Weteringen
TETanja van Essen
Tanja van Essen
NGNorani H. Gangaram-Panday
Norani H. Gangaram-Panday
TGTom G. Goos
Tom G. Goos
RJRogier C.J. de Jonge
Rogier C.J. de Jonge
IRIrwin K.M. Reiss
Irwin K.M. Reiss
Introduction: Traditional transcutaneous oxygen (tcPO2) measurements are affected by measurement drift, limiting accuracy and usability. The new potentially drift-free oxygen fluorescence quenching technique has been combined in a single sensor with conventional transcutaneous carbon dioxide (tcPCO2) monitoring. This study aimed to validate optical tcPO2 and conventional tcPCO2 against arterial blood gas samples in preterm neonates and determine measurement drift. Methods: In this prospective observational study, during regular care, transcutaneous measurements were paired to arterial blood gases from preterm neonates aged 24–31 weeks of gestational age (GA) with an arterial catheter. Samples were included based on stability criteria and stratified for sepsis status. Agreement was assessed using the Bland-Altman analysis. Measurement drift per hour was calculated. Results: Sixty-eight premature neonates were included {median (interquartile range [IQR]) GA of 26 4/7 [25 3/7–27 5/7] weeks}, resulting in 216 stable paired samples. Agreement of stable samples in neonates without sepsis (n = 38) and with suspected sepsis (n = 112) was acceptable for tcPO2 and good for tcPCO2. However, in stable samples of neonates with sepsis (n = 66), tcPO2 agreement (bias and 95% limits of agreement) was −32.6 (−97.0 to 31.8) mm Hg and tcPCO2 agreement was 4.2 (−10.5 to 18.9) mm Hg. The median (IQR) absolute drift values were 0.058 (0.0231–0.1013) mm Hg/h for tcPO2 and 0.30 (0.11–0.64) mm Hg/h for tcPCO2. Conclusion: The accuracy of optical tcPO2 in premature neonates was acceptable without sepsis, while electrochemically measured tcPCO2 remained accurate under all circumstances. Measurement drift was negligible for tcPO2 and highly acceptable for tcPCO2.

6 May 2022 in Scientific Reports
Verified
Journal Article
Open access
PDF file
NGNorani H. Gangaram-Panday
Norani H. Gangaram-Panday
LNLouwrina H. te Nijenhuis
Louwrina H. te Nijenhuis
IFIlya Fine
Ilya Fine
IRIrwin Reiss
Irwin Reiss
WWWillem van Weteringen
Willem van Weteringen
Current haemodynamic monitoring is mainly aimed at the macrocirculation. Multiple studies have demonstrated the importance of the microcirculation in relation to the patient’s condition and impact of treatment strategies. However, continuous monitoring of the microcirculation is not yet possible in the neonatal field. A novel dynamic light scattering (DLS) sensor technology for continuous monitoring of the microcirculation was investigated in the neonatal population. Thirty-one haemodynamically stable infants were included. Sequential measurements at the forehead, upper extremity, thorax, abdomen and lower extremity were conducted with the DLS sensor. For analyses stable measurements were selected. The DLS parameters, total blood flow (TBF) and relative blood velocity (RBV), were compared between measurement locations. Changes in relative haemodynamic indices (relHIs), indicating the distribution of blood flow in the microcirculatory blood vessels, were associated with heart rate decelerations. Measurements performed at the forehead had significantly lower TBF levels, compared to measurements at other locations. Early changes in relHIs around a heart rate deceleration were recorded a median (IQR) of 22.0 (13.5–27.0) s before the onset. Measurement of the currently unavailable parameters TBF, RBV and relHIs is possible with DLS technology. Validation of the DLS technology is needed for clinical implementation.

28 May 2020 in Neonatology
Verified
Journal Article
Open access
PDF file
NGNorani H. Gangaram-Panday
Norani H. Gangaram-Panday
TETanja van Essen
Tanja van Essen
TGTom G. Goos
Tom G. Goos
RJRogier C.J. de Jonge
Rogier C.J. de Jonge
IRIrwin K.M. Reiss
Irwin K.M. Reiss
WWWillem van Weteringen
Willem van Weteringen
Background: Heart rate (HR) detection in premature infants using electrocardiography (ECG) is challenging due to a low signal amplitude and the fragility of the premature skin. Recently, the dynamic light scattering (DLS) technique has been miniaturized, allowing noninvasive HR measurements with a single sensor. Objective: The aim was to determine the accuracy of DLS for HR measurement in infants, compared to ECG-derived HR. Methods: Stable infants with a gestational age of ≥26 weeks, monitored with ECG, were eligible for inclusion. HR was measured with the DLS sensor at 5 different sites for 15 min each. We recorded every 10th second of the DLS-derived HR and the DLS signal-to-noise ratio (SNR), and the ECG-derived HR was extracted for analysis. Patients were randomly divided into 2 groups. In the first group, the optimal SNR cut-off value was determined and then applied to the second group to assess agreement. Results: HR measurements from 31 infants were analyzed. ECG-DLS paired data points were collected at the forehead, an upper extremity, the thorax, a lower extremity, and the abdomen. When applying the international accuracy standard for HR detection, DLS accuracy in the first group (n = 15) was optimal at the forehead (SNR cut-off 1.66). Application of this cut-off to the second group (n = 16) showed good agreement between DLS-derived HR and ECG-derived HR (bias –0.73 bpm; 95% limits of agreement –15.46 and 14.00 bpm) at the forehead with approximately 80% (i.e., 1,066/1,310) of all data pairs remaining. Conclusion: The investigated DLS sensor was sensitive to movement, overall providing less accurate HR measurements than ECG and pulse oximetry. In this study population, specific measurement sites provided excellent signal quality and good agreement with ECG-derived HR.

30 March 2023 in Neonatology
Verified
Journal Article
Open access
PDF file
TETanja van Essen
Tanja van Essen
NGNorani H. Gangaram-Panday
Norani H. Gangaram-Panday
WWWillem van Weteringen
Willem van Weteringen
TGTom G. Goos
Tom G. Goos
IRIrwin K.M. Reiss
Irwin K.M. Reiss
RJRogier C.J. de Jonge
Rogier C.J. de Jonge
Introduction: Transcutaneous blood gas monitoring allows for continuous non-invasive evaluation of carbon dioxide and oxygen levels. Its use is limited as its accuracy is dependent on several factors. We aimed to identify the most influential factors to increase usability and aid in the interpretation of transcutaneous blood gas monitoring. Methods: In this retrospective cohort study, transcutaneous blood gas measurements were paired to arterial blood gas withdrawals in neonates admitted to the neonatal intensive care unit. The effects of patient-related, microcirculatory, macrocirculatory, respiratory, and sensor-related factors on the difference between transcutaneously and arterially measured carbon dioxide and oxygen values (ΔPCO2 and ΔPO2) were evaluated using marginal models. Results: A total of 1,578 measurement pairs from 204 infants with a median [interquartile range] gestational age of 273/7 [261/7–313/7] weeks were included. ΔPCO2 was significantly associated with the postnatal age, arterial systolic blood pressure, body temperature, arterial partial pressure of oxygen (PaO2), and sensor temperature. ΔPO2 was, with the exception of PaO2, additionally associated with gestational age, birth weight Z-score, heating power, arterial partial pressure of carbon dioxide, and interactions between sepsis and body temperature and sepsis and the fraction of inspired oxygen. Conclusion: The reliability of transcutaneous blood gas measurements is affected by several clinical factors. Caution is recommended when interpreting transcutaneous blood gas values with an increasing postnatal age due to skin maturation, lower arterial systolic blood pressures, and for transcutaneously measured oxygen values in the case of critical illness.

29 March 2022 in Pediatric Research
Verified
Journal Article
Closed access
PDF file
NGNorani H. Gangaram-Panday
Norani H. Gangaram-Panday
TETanja van Essen
Tanja van Essen
WWWillem van Weteringen
Willem van Weteringen
MDMarjolein H. G. Dremmen
Marjolein H. G. Dremmen
TGTom G. Goos
Tom G. Goos
IRIrwin K. M. Reiss
Irwin K. M. Reiss

11 March 2025 in Paediatric Respiratory Reviews
Verified
Journal Article
Open access
NGN.H. Gangaram-Panday
N.H. Gangaram-Panday
JPJ.A. Poppe
J.A. Poppe
ATA.N. Tintu
A.N. Tintu
CPC.F. Poets
C.F. Poets
IRI.K.M. Reiss
I.K.M. Reiss
SSS.H.P. Simons
S.H.P. Simons
In neonatal care, maintaining oxygen levels in the target range is essential to minimize adverse outcomes. Both episodes of hyperoxemia and hypoxemia are associated with adverse neonatal outcomes. Criteria to determine the hypoxemic and hyperoxemic burden are currently not standardized or generally applied in clinical care. This results in difficulty to identify clinically relevant events in preterm infants. Clinical decisions and interventions are therefore mostly based on the experience of the clinical team. This systematic review aims to provide an overview of the used definitions for hypoxemia and hyperoxemia in preterm infants, based on continuous monitoring techniques and the relation to neonatal outcome (PROSPERO: CRD42023493201).