This topical review provides an up-to-date overview of the theoretical and practical aspects of therapeutic kilovoltage x-ray beam dosimetry. Kilovoltage x-ray beams have the property that the maximum dose occurs very close to the surface and thus, they are predominantly used in the treatment of skin cancers but also have applications for the treatment of other cancers. In addition, kilovoltage x-ray beams are used in intra operative units, within animal irradiators and in on-board imagers on linear accelerators and kilovoltage dosimetry is important in these applications as well. This review covers both reference and relative dosimetry of kilovoltage x-ray beams and provides recommendations for clinical measurements based on the literature to date. In particular, practical aspects for the selection of dosimeter and phantom material are reviewed to provide suitable advice for medical physicists. An overview is also presented of dosimeters other than ionization chambers which can be used for both relative and in vivo dosimetry. Finally, issues related to the treatment planning and the use of Monte Carlo codes for solving radiation transport problems in kilovoltage x-ray beams are presented.

12 August 2009 in Medical Physics
Verified
Journal Article
Closed access
RHRobin Hill
Robin Hill
ZMZhao Mo
Zhao Mo
MHMamoon Haque
Mamoon Haque
CBClive Baldock
Clive Baldock

28 July 2010 in Medical Physics
Verified
Journal Article
Closed access
RHRobin Hill
Robin Hill
ZKZdenka Kuncic
Zdenka Kuncic
CBClive Baldock
Clive Baldock

19 October 2005 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
RHR Hill
R Hill
LHLois Holloway
Lois Holloway
CBC Baldock
C Baldock
Solid phantoms are widely used in radiation therapy for both relative and reference dosimetry. Two water equivalent phantoms, RMI-457 Solid Water and Plastic Water, were evaluated for use in kilovoltage x-ray dosimetry in the energy range from 75 to 300 kVp. Relative and reference dosimetry measurements were performed in the solid phantoms and compared with water. The results indicate that RMI-457 Solid Water could be used for output factor determination for all energies tested and the measurement of percentage depth doses for the 300 kVp x-ray beam, with data agreeing to within 1%, compared to the same measurements in water. For the same criteria, Plastic Water could only be used for output factor determination of the 300 kVp x-ray beam. The superior agreement of the calculated mass-energy absorption coefficients for Solid Water and water, as compared to Plastic Water and water was consistent with the experimental results. Reference dosimetry is not recommended with the solid phantoms for the energies studied due to the lack of published correction factors. It is recommended that any solid phantom be tested by comparison with water in the same manner before being used for the dosimetry of kilovoltage x-ray beams.

31 March 2011 in Medical Physics
Verified
Journal Article
Closed access
TGTina Gorjiara
Tina Gorjiara
RHRobin Hill
Robin Hill
ZKZdenka Kuncic
Zdenka Kuncic
JAJohn Adamovics
John Adamovics
SBStephen Bosi
Stephen Bosi
CBClive Baldock
Clive Baldock

1 August 2008 in Radiation Measurements
Verified
Journal Article
Closed access
RHR.F. Hill
R.F. Hill
SBS. Brown
S. Brown
CBC. Baldock
C. Baldock