Nouruddin Wageih Ali

Nouruddin Wageih Ali

Auto-generated profile, based on publicly available information

Nouruddin Wageih Ali

Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Beni-Suef University, Al shaheed Shehata Ahmed Hegazy st., 62514 Beni-Suef, Egypt

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2015 in Journal of Pharmaceutical and Biomedical Analysis
Verified
Journal Article
Closed access
EAEglal A. Abdelaleem
Eglal A. Abdelaleem
Ibrahim NaguibIbrahim Naguib
Ibrahim Naguib
EHEman S. Hassan
Eman S. Hassan
NANouruddin W. Ali
Nouruddin W. Ali

1 April 2012 in Journal of Pharmaceutical Analysis
Verified
Journal Article
Open access
NANouruddin W. Ali
Nouruddin W. Ali
SASamah Sayed Abbas
Samah Sayed Abbas
HZHala El-Sayed Zaazaa
Hala El-Sayed Zaazaa
MAMaha Mohamed Abdelrahman
Maha Mohamed Abdelrahman
MAMohamed Abdelkawy
Mohamed Abdelkawy
Three sensitive, selective and reproducible stability-indicating methods are presented for determination of nitazoxanide (NTZ), a new anti-protozoal drug, in presence of its degradation products. Method A utilizes the first derivative of ratio spectra spectrophotometry by measurement of the amplitude at 364.4 nm using one of the degradation products as a divisor. Method B is a chemometric-assisted spectrophotometry, where principal component regression (PCR) and partial least squares (PLS) were applied. These two approaches were successfully applied to quantify NTZ in presence of degradation products using the information included in the absorption spectra in the range 260-360 nm. Method C is based on the separation of NTZ from its degradation products followed by densitometric measurement of the bands at 254 nm. The separation was carried out on silica gel 60F254, using chloroform-methanol-ammonia solution-glacial acetic acid (95:5:1:1 by volume, pH=5.80) as a developing system. These methods are suitable as stability-indicating methods for the determination of NTZ in presence of its degradation products either in bulk powder or in pharmaceutical formulations. Statistical analysis of the results has been carried out revealing high accuracy and good precision.

30 December 2011 in Biomedical Chromatography
Verified
Journal Article
Closed access
PDF file
NANouruddin W. Ali
Nouruddin W. Ali
HZHala A. ZaaZaa
Hala A. ZaaZaa
MAM. Abdelkawy
M. Abdelkawy
MMMaimana A. Magdy
Maimana A. Magdy

1 May 2017 in Arabian Journal of Chemistry
Verified
Journal Article
Open access
NANouruddin W. Ali
Nouruddin W. Ali
Mohammed GamalMohammed Gamal
Mohammed Gamal
MAMohammed Abdelkawy
Mohammed Abdelkawy
RP-HPLC chromatographic method was developed for the determination of hyoscine N-butyl bromide (HBB) and Paracetamol (PAR). In this chromatographic method, HBB and PAR were separated using C18 (25cm×4.6mm i.d. 5μm particle size) column as a stationary phase and water: methanol (50:50, V/V pH adjusted to 3.9 with CF3COOH acid) as a mobile phase, maintaining the flow rate at 1.0mLmin−1 with UV detection at 210nm. The proposed method was successfully applied for the determination of HBB and PAR in pure form over a concentration range of 2.0–50.0μgmL−1 for HBB with mean percentage recovery of 100.10±0.475 and over a concentration range of 5.0–200.0μgmL−1 for PAR with mean percentage recovery of 99.87±0.942 and in their pharmaceutical formulations (Buscopan plus® tablets, Buscamol® tablets and Buscopan plus® suppositories)

1 June 2012 in Acta Pharmaceutica
Verified
Journal Article
Open access
NANouruddin Ali
Nouruddin Ali
MHMaha Hegazy
Maha Hegazy
MAMohamed Abdelkawy
Mohamed Abdelkawy
EAEglal Abdelaleem
Eglal Abdelaleem
Simultaneous determination of methocarbamol and ibuprofen or diclofenac potassium using mean centering of the ratio spectra method Accurate and sensitive methods were developed for simultaneous determination of methocarbamol and ibuprofen or diclofenac potassium in their binary mixtures, and in the presence of a methocarbamol related substance (guaifenesin) using mean centering of the ratio spectra method. The results obtained were statistically compared with the reported HPLC methods; no significant difference between the proposed methods and the reported methods was found regarding either accuracy or precision.

1 November 2014 in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
Verified
Journal Article
Closed access
HZHala E. Zaazaa
Hala E. Zaazaa
MAMaha M. Abdelrahman
Maha M. Abdelrahman
NANouruddin W. Ali
Nouruddin W. Ali
MMMaimana A. Magdy
Maimana A. Magdy
MAM. Abdelkawy
M. Abdelkawy