Chang Sheng Zhou

Chang Sheng Zhou

Auto-generated profile, based on publicly available information

Chang Sheng Zhou

Department of Radiology, Jinling Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing 210002, China

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 March 2021 in American Journal of Neuroradiology
Verified
Journal Article
Closed access
PDF file
ZSZ. Shi
Z. Shi
GCGuozhong Chen
Guozhong Chen
LML. Mao
L. Mao
XLX.L. Li
X.L. Li
CZC.S. Zhou
C.S. Zhou
Longjiang ZhangLongjiang Zhang
Longjiang Zhang
BACKGROUND AND PURPOSE: Small intracranial aneurysms are being increasingly detected while the rupture risk is not well-understood. We aimed to develop rupture-risk models of small aneurysms by combining clinical, morphologic, and hemodynamic information based on machine learning techniques and to test the models in external validation datasets. MATERIALS AND METHODS: From January 2010 to December 2016, five hundred four consecutive patients with only small aneurysms (<5 mm) detected by CTA and invasive cerebral angiography (or surgery) were retrospectively enrolled and randomly split into training (81%) and internal validation (19%) sets to derive and validate the proposed machine learning models (support vector machine, random forest, logistic regression, and multilayer perceptron). Hemodynamic parameters were obtained using computational fluid dynamics simulation. External validation was performed in other hospitals to test the models. RESULTS: The support vector machine performed the best with areas under the curve of 0.88 (95% CI, 0.85–0.92) and 0.91 (95% CI, 0.74–0.98) in the training and internal validation datasets, respectively. Feature ranks suggested hemodynamic parameters, including stable flow pattern, concentrated inflow streams, and a small (<50%) flow-impingement zone, and the oscillatory shear index coefficient of variation, were the best predictors of aneurysm rupture. The support vector machine showed an area under the curve of 0.82 (95% CI, 0.69–0.94) in the external validation dataset, and no significant difference was found for the areas under the curve between internal and external validation datasets (P = .21). CONCLUSIONS: This study revealed that machine learning had a good performance in predicting the rupture status of small aneurysms in both internal and external datasets. Aneurysm hemodynamic parameters were regarded as the most important predictors.

1 October 2024 in Radiology
Verified
Journal Article
Closed access
BGBangjun Guo
Bangjun Guo
WXWei Xing
Wei Xing
CHChunhong Hu
Chunhong Hu
YZYunfei Zha
Yunfei Zha
XYXindao Yin
Xindao Yin
FGfor the China CT-FFR Study 3 Group
for the China CT-FFR Study 3 Group
Automated coronary CT–derived fractional flow reserve was associated with reduced 90-day invasive coronary angiography rate without an increase in major adverse cardiac events up to 1 year.

1 May 2025 in Radiology: Artificial Intelligence
Verified
Journal Article
Closed access
ZSZhao Shi
Zhao Shi
BHBin Hu
Bin Hu
MLMengjie Lu
Mengjie Lu
MZManting Zhang
Manting Zhang
HYHaiting Yang
Haiting Yang
FGfor the China Aneurysm AI Project Group
for the China Aneurysm AI Project Group
Radiologists assisted by the proposed sham–artificial intelligence (AI) model, acting as a placebo control for a standard-AI model to mitigate biases in intracranial aneurysm diagnosis, had noninferior sensitivity and specificity compared with radiologists alone.

20 January 2025 in American Journal of Neuroradiology
Verified
Journal Article
Closed access
PDF file
XCXiaoQing Cheng
XiaoQing Cheng
BTBing Tian
Bing Tian
LHLi Jun Huang
Li Jun Huang
XSXi Shen
Xi Shen
ALAn Yu Liao
An Yu Liao
GLGuangming Lu
Guangming Lu
BACKGROUND AND PURPOSE: Early identification of malignant cerebral edema (MCE) in patients with acute ischemic stroke is crucial for timely interventions. We aimed to identify regions critically associated with MCE using the Alberta Stroke Program Early Computed Tomography Score (ASPECTS) to evaluate the association between location-specific-net water uptake (NWU) and MCE. MATERIALS AND METHODS: This multicentre, retrospective cohort study included patients with acute ischemic stroke following large anterior circulation occlusion. The ASPECTS was determined by RAPID ASPECTS software. ASPECTS-NWU and Region-NWU were calculated automatically by comparing the Hounsfield units values in the ischemic and contralateral regions. Critical ASPECTS MCE regions and Region-NWU were evaluated by multivariate logistic regression and the areas under the receiver operating characteristic curves (AUCs). RESULTS: The study included 513 patients. Multivariate analysis showed that the ASPECTS insula (OR=2.49; 95% CI, 1.44–4.31) and M5 (OR=1.59; 95% CI, 1.11–3.41) regions were significantly associated with MCE. After adjustment, only the insula (OR=2.34; 95% CI, 1.23–4.45) was independently associated with MCE. Univariable ROC analysis found AUCs for Insula-NWU (AUC, 0.70; 95% CI, 0.65– 0.76)and ASPECTS-NWU (AUC, 0.64; 95% CI, 0.58-0.70) .The Insula-NWU had better diagnostic power than ASPECTS-NWU (DeLong test; P=0.01). A multivariate regression model that combined the NIHSS, ASPECTS, insula involvement, and Insula-NWU had good discriminatory power (AUC=0.80; 95% CI, 0.74–0.86) and better diagnostic power than Insula-NWU (DeLong test; P<0.01). CONCLUSIONS: Brief statement directed to the stated purpose or hypothesis; no references should be cited.The insula region is critical for MCE, and Insula-NWU has better prediction efficacy than ASPECTS-NWU. This method does not rely on advanced imaging, facilitating rapid assessment in emergencies. ABBREVIATIONS: ASPECTS = the Alberta Stroke Program Early Computed Tomography Score; AUC= the areas under the receiver operating characteristic curve; CT=computed tomography; CTP=CT perfusion; HU = hounsfield unit; MCE = malignant cerebral edema; NCCT=non-contrast Computed Tomography; NWU = net water uptake; ROC = receiver operating characteristic curve.