Deyong Yang

Deyong Yang

Auto-generated profile, based on publicly available information

Deyong Yang

School of Agricultural Engineering, Jiangsu University, Zhenjiang 212013, China

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 May 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
子周子彪 周
子彪 周
LXLi Xuchun
Li Xuchun
XWXiangyu Wang
Xiangyu Wang
DYDeyong Yang
Deyong Yang
ZLZhenwei Liang
Zhenwei Liang
Continuous monitoring of impurity content and breakage rate in combine harvester grain flow remains challenging because representative samples are difficult to acquire online, and the visual targets are small, dense, and imbalanced. In this study, a prototype monitoring system integrating sample collection, controlled conveying, image acquisition, and embedded processing was developed for online grain-quality sensing during harvesting. To satisfy the requirement for sidewall sampling from the vertical grain conveying auger, centrifugal sampling and screw conveying were used to extract and transport grain-flow samples, and a stable imaging environment was established using an industrial camera and dedicated illumination. Pixel-area-to-mass mapping models were established for broken grains and impurity targets, with coefficients of determination higher than 0.93. In addition, a lightweight improved YOLOv8-Seg model was developed to recognize and segment broken grains and impurity targets under dense small-target conditions. Bench-scale validation showed that the relative error of impurity content ranged from 1.02% to 13.04%, with an average of 6.09%, while the absolute error of breakage rate ranged from 0.01 to 0.02 percentage points. These results demonstrate the feasibility of the proposed method for online estimation of impurity content and breakage rate under bench-scale conditions and provide a basis for future machine integration and field validation.

3 July 2013 in Journal of Medical Devices
Verified
Journal Article
Closed access
PDF file
RMRuyu Ma
Ruyu Ma
HDHua Ding
Hua Ding
JWJianhe Wei
Jianhe Wei
DYDeyong Yang
Deyong Yang
If a custom hip stem could be designed according to X-ray films, the cost of the hip stem would be reduced, and a simpler designing method could be provided than using computer tomography images. In addition, the problem, which is that hip stems cannot be designed for some revision operations because of metal artifacts in computer tomography images, could be solved. A software system for designing custom hip stems based on X-ray films was developed. In order to verify whether the software system could be used, eleven femurs were used for this study. Hip stems for these eleven femurs were designed by using the software system. Ten of these femurs were taken computer tomography scans directly. According to the data collected from the computer tomography images, models of these ten femurs were rebuilt. Ten hip stem models, designed for these ten femurs, were simulated to be inserted into corresponding femur models. Results show each of the ten hip stems matches its corresponding femur. The hip stem designed for the remaining femur was manufactured and inserted in the remaining femur. Cancellous bone, retained in the matching area, was about 1–1.5 mm thick. From the above verifications, it could be concluded that the software system for designing custom hip stems based on X-ray films could be used to design custom hip stems.