Shan Gao

Shan Gao

Auto-generated profile, based on publicly available information

Shan Gao

Rensselaer Polytechnic Institute

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 May 2022 in Optica
Verified
Journal Article
Closed access
JSJason T. Smith
Jason T. Smith
ARAlena Rudkouskaya
Alena Rudkouskaya
SGShan Gao
Shan Gao
JGJuhi M. Gupta
Juhi M. Gupta
AUArin Ulku
Arin Ulku
XMXavier Michalet
Xavier Michalet
Near-infrared (NIR) fluorescence lifetime imaging (FLI) provides a unique contrast mechanism to monitor biological parameters and molecular events in vivo. Single-photon avalanche diode (SPAD) cameras have been recently demonstrated in FLI microscopy (FLIM) applications, but their suitability for in vivo macroscopic FLI (MFLI) in deep tissues remains to be demonstrated. Herein, we report in vivo NIR MFLI measurement with SwissSPAD2, a large time-gated SPAD camera. We first benchmark its performance in well-controlled in vitro experiments, ranging from monitoring environmental effects on fluorescence lifetime, to quantifying Förster resonant energy transfer (FRET) between dyes. Next, we use it for in vivo studies of target-drug engagement in live and intact tumor xenografts using FRET. Information obtained with SwissSPAD2 was successfully compared to that obtained with a gated intensified charge-coupled device (ICCD) camera, using two different approaches. Our results demonstrate that SPAD cameras offer a powerful technology for in vivo preclinical applications in the NIR window.

10 August 2022 in Biomedical Optics Express
Verified
Journal Article
Closed access
SGShan Gao
Shan Gao
MLMengzhou Li
Mengzhou Li
JSJason T. Smith
Jason T. Smith
XIXavier Intes
Xavier Intes
We report on the system design and instrumental characteristics of a novel time-domain mesoscopic fluorescence molecular tomography (TD-MFMT) system for multiplexed molecular imaging in turbid media. The system is equipped with a supercontinuum pulsed laser for broad spectral excitation, based on a high-density descanned raster scanning intensity-based acquisition for 2D and 3D imaging and augmented with a high-dynamical range linear time-resolved single-photon avalanche diode (SPAD) array for lifetime quantification. We report on the system’s spatio-temporal and spectral characteristics and its sensitivity and specificity in controlled experimental settings. Also, a phantom study is undertaken to test the performance of the system to image deeply-seated fluorescence inclusions in tissue-like media. In addition, ex vivo tumor xenograft imaging is performed to validate the system’s applicability to the biological sample. The characterization results manifest the capability to sense small fluorescence concentrations (on the order of nanomolar) while quantifying fluorescence lifetimes and lifetime-based parameters at high resolution. The phantom results demonstrate the system’s potential to perform 3D multiplexed imaging thanks to spectral and lifetime contrast in the mesoscopic range (at millimeters depth). The ex vivo imaging exhibits the prospect of TD-MFMT to resolve intra-tumoral heterogeneity in a depth-dependent manner.

28 April 2022 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
NNNavid Ibtehaj Nizam
Navid Ibtehaj Nizam
MOMarien Ochoa
Marien Ochoa
JSJason T. Smith
Jason T. Smith
SGShan Gao
Shan Gao
XIXavier Intes
Xavier Intes
Diffuse optical imaging (DOI) has found utility for many applications in biomedicine, including neuroscience, tissue physiologic monitoring, and diagnostics. DOI encompasses various modalities that leverage near-infrared light sensing or fluorescence-based contrast(s) to probe biotissue status. Of importance, biological samples imaged in DOI are intact, strongly diffusive tissues. Hence, DOI is typically characterized by the use of highly ill-posed light transport models. Two main modalities within DOI that often target macroscopic imaging of tissues are diffuse optical tomography (DOT)1 and topography (DOTP).2,3 While DOT aims to retrieve the full three-dimensional (3D) distribution of the target absorbers, DOTP only aims at retrieving their two-dimensional (2D) depth profiles. Hence, DOTP is better suited for applications where fast imaging over large fields of views is desired, while DOT can provide higher 3D spatial accuracy of the target. Despite their differences in output, DOT and DOTP recover the targets of interest within tissues through an inverse problem. This inverse problem is often linearized to reduce its ill-posedness.4 As for most DOI applications, the reconstruction accuracy is then dependent on realistically modeling photon transport within the sample and in the types of experimental or processing constraints enforced on the model. Thus, the image formation problem in DOI remains mostly an expert, lab-centric discipline.4 – 6 Though following ubiquitous trends in all the biomedical imaging fields, there has been a gradual interest in leveraging deep learning (DL) approaches to achieve the challenging DOT and DOPT computational task(s).1,7 DL’s use is appealing toward providing robust, user-friendly, ultrafast, and computationally efficient models that can replace the various inverse solving strategies currently used in DOI. Beyond ease of use, DL methods have been demonstrated to be orders of magnitude faster and correspondingly, better positioned for various biomedical applications that require “real-time” feedback.7

10 April 2023 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
LCLuis Chavez
Luis Chavez
SGShan Gao
Shan Gao
XIXavier Intes
Xavier Intes
SignificanceFluorescence lifetime imaging in the shortwave infrared (SWIR) is expected to enable high-resolution multiplexed molecular imaging in highly scattering tissue.AimTo characterize the brightness and fluorescence lifetime of commercially available organic SWIR fluorophores and benchmark them against the tail emission of conventional NIR-excited probes.ApproachCharacterization was performed through our established time-domain mesoscopic fluorescence molecular tomography system integrated around a time-correlated single-photon counting-single-photon avalanche diode array. Brightness and fluorescence lifetime were measured for NIR and SWIR probes >1000 nm. Simultaneous probe imaging was then performed to assess their potential for multiplexed studies.ResultsThe NIR probes outperformed SWIR probes in brightness while the mean fluorescence lifetimes of the SWIR probes were extremely short. The phantom study demonstrated the feasibility of lifetime multiplexing in the SWIR window with both NIR and SWIR probes.ConclusionsLong-tail emission of NIR probes outperformed the SWIR probes in brightness >1000 nm. Fluorescence lifetime was readily detectable in the SWIR window, where the SWIR probes showed shorter lifetimes compared to the NIR probes. We demonstrate the feasibility of lifetime multiplexing in the SWIR window, which paves the way for in vivo multiplexed studies of intact tissues at improved resolution.

12 February 2025 in Biomedical Optics Express
Verified
Journal Article
Closed access
LCLuis Chavez
Luis Chavez
SGShan Gao
Shan Gao
VPVikas Pandey
Vikas Pandey
NYNanxue Yuan
Nanxue Yuan
SRSaif Ragab
Saif Ragab
XIXavier Intes
Xavier Intes
We developed a novel methodology for manufacturing multimodal, tissue-mimicking phantoms that exhibit both molecular and biomechanical contrast. This methodology leverages the immiscibility of silicone and hydrogels to create solid mesoscale phantoms with localized regions of precisely controlled fluorescence, including fluorescence lifetime properties, and adjustable stiffness, without requiring physical barriers. Mechanical, fluorescent, and optical characterization confirmed the tunability of the phantoms across a range of values relevant to biomedical applications. A macroscale 3D phantom was fabricated, and its properties were validated through fluorescence lifetime imaging (FLI) and optical coherence elastography (OCE). Validation demonstrated the successful tuning of both mechanical and fluorescence lifetime contrasts within a 3D structure, highlighting the feasibility of multimodal FLI-OCE. This new phantom manufacturing process is expected to support the development and validation of new multimodal imaging approaches to study molecular and biomechanical properties of the tumor microenvironment (TME), as well as their impact on therapeutic efficacy, and to enhance targeted therapies.

14 December 2021
Verified
Book Chapter
Closed access
PDF file
DFDenzel Faulkner
Denzel Faulkner
MOMarien Ochoa
Marien Ochoa
NNNavid Ibtehaj Nizam
Navid Ibtehaj Nizam
SGShan Gao
Shan Gao
XIXavier Intes
Xavier Intes
This chapter discusses the field of diffuse fluorescence tomography in terms of fluorescence diffuse optical tomography (FDOT) and fluorescence molecular tomography (FMT). A brief overview of the forward photon propagation model is given. In addition, the techniques and challenges associated with solving the inverse problem, required for successful reconstruction, are discussed. Moreover, special attention is given to the different instrumentation used in diffuse fluorescence tomography. This includes the instrumentation associated with adequate illumination of the sample as well as efficient detection. Furthermore, the diverse applications of diffuse fluorescence tomography are explored, ranging from its use in biomarkers to preclinical applications and translational imaging. Finally, the chapter looks at the emerging technologies, which will shape the field in the near future.