Luca Furlani

Luca Furlani

Auto-generated profile, based on publicly available information

Luca Furlani

Università degli studi di Udine, Udine, Italy

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2016 in Experimental Thermal and Fluid Science
Verified
Journal Article
Open access
LFLuca Furlani
Luca Furlani
AAAlessandro Armellini
Alessandro Armellini
LCLuca Casarsa
Luca Casarsa
The work reports for the first time detailed experimental data about the flow field inside an advanced leading edge cooling channel for gas turbine blades. The geometry key features are multiple internal impinging jests and coolant extraction for blade film cooling protection. Measurements have been performed by means of 2D and Stereo PIV, in both static and rotating conditions, with Reynolds number of 30k and 10k and a Rotation number of 0.05, both defined with reference to the jet characteristics. Different crossflow conditions in the feeding channel have been used to simulate the three main blade regions (i.e. HUB, MID, and TIP). The flow inside the feeding channel is significantly affected by rotation, conversely, when moving inside the main impingement duct, the jet core has been found to be only marginal modified due to rotation. Finally, a substantial Reynolds number independence has been found

1 June 2017 in Journal of Engineering for Gas Turbines and Power
Verified
Journal Article
Closed access
PDF file
DMDaniele Massini
Daniele Massini
EBEmanuele Burberi
Emanuele Burberi
CCCarlo Carcasci
Carlo Carcasci
LCLorenzo Cocchi
Lorenzo Cocchi
BFBruno Facchini
Bruno Facchini
LFLuca Furlani
Luca Furlani
A detailed aerothermal characterization of an advanced leading edge (LE) cooling system has been performed by means of experimental measurements. Heat transfer coefficient distribution has been evaluated exploiting a steady-state technique using thermochromic liquid crystals (TLCs), while flow field has been investigated by means of particle image velocimetry (PIV). The geometry key features are the multiple impinging jets and the four rows of coolant extraction holes, and their mass flow rate distribution is representative of real engine working conditions. Tests have been performed in both static and rotating conditions, replicating a typical range of jet Reynolds number (Rej), from 10,000 to 40,000, and rotation number (Roj) up to 0.05. Different crossflow conditions (CR) have been used to simulate the three main blade regions (i.e., tip, mid, and hub). The aerothermal field turned out to be rather complex, but a good agreement between heat transfer coefficient and flow field measurement has been found. In particular, jet bending strongly depends on crossflow intensity, while rotation has a weak effect on both jet velocity core and area-averaged Nusselt number. Rotational effects increase for the lower crossflow tests. Heat transfer pattern shape has been found to be substantially Reynolds independent.

1 November 2016 in Energy Procedia
Verified
Journal Article
Open access
FPFabio Pagnacco
Fabio Pagnacco
LFLuca Furlani
Luca Furlani
AAAlessandro Armellini
Alessandro Armellini
LCLuca Casarsa
Luca Casarsa
ADAnthony Davis
Anthony Davis

24 January 2017 in Journal of Turbomachinery
Verified
Journal Article
Open access
PDF file
LFLuca Furlani
Luca Furlani
AAAlessandro Armellini
Alessandro Armellini
LCLuca Casarsa
Luca Casarsa
The flow field inside a triangular cooling channel for the leading edge of a gas turbine blade has been investigated. The efforts were focused on the investigation of the interaction between effects of rotation, of buoyancy forces, and those induced by turbulence promoters, i.e., perpendicular square ribs placed on both leading and trailing sides of the duct. Particle image velocimetry (PIV) and stereo-PIV measurements have been performed for ReDh = 104, rotation number of 0, 0.2, and 0.6, and buoyancy parameter equal to 0, 0.08, and 0.7. Coriolis secondary flows are detected in the duct cross section, but contrary to the smooth case, they are characterized by a single main vortex and are less affected by an increase of the rotation parameter. Moreover, their main topology is only marginally sensitive to the buoyancy forces. Conversely, the features of the recirculation structure downstream the ribs turned out to be more sensitive to both the buoyancy forces and to the stabilizing/destabilizing effect on the separated shear layer induced by rotation.

17 March 2017 in Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy
Verified
Journal Article
Closed access
GBGiovanna Barigozzi
Giovanna Barigozzi
Silvia RavelliSilvia Ravelli
Silvia Ravelli
AAAlessandro Armellini
Alessandro Armellini
LCLuca Casarsa
Luca Casarsa
LFLuca Furlani
Luca Furlani
The present work deepens the analysis of the flow field inside a triangular equilateral channel with turbulence promoters, perpendicular to the radial direction, on both leading and trailing sides, under rotation and both isothermal and nonisothermal conditions (i.e. with centrifugal buoyancy forces). Simulations have been performed at constant Re = 10,000, Ro = 0–0.2–0.6, and Bo = 0–0.08–0.7, the latter corresponding to 80℃ temperature difference between fluid and walls. These conditions match those of the particle image velocimetry measurements, used for comparison against predictions. After proper validation, the numerical modeling helped with the assessment of the flow field evolution along the radial extension of the cooling channel. It has been possible to determine the path of the coolant throughout the channel and localize where the heat transfer would have been enhanced/decreased by secondary flow structures, with respect to the stationary case. Furthermore, a rather Bo-independency of the flow field in this kind of geometry has been confirmed. The analysis presented in this paper finds support from the thermal data available from the open literature, which is rich of thermal analysis indeed, but lacks a detailed description of internal flow fields.

13 June 2016
Verified
Conference Paper
Closed access
PDF file
FPFabio Pagnacco
Fabio Pagnacco
LFLuca Furlani
Luca Furlani
AAAlessandro Armellini
Alessandro Armellini
LCLuca Casarsa
Luca Casarsa
ADAnthony Davis
Anthony Davis
The present contribution is focused on heat transfer measurements on internal cooling channels of a high pressure gas turbine blade in static and rotating conditions. A novel rig designed for the specific purpose was used to assess the heat transfer coefficients on a full internal cooling scheme of an idealized blade. The channel has a multi-pass design. Coolant enters at the blade hub in the leading edge region and move radially outwards inside a two-sided ribbed channel. The second passage is again a two-sided ribbed channel with a trapezoidal cross section of high aspect ratio, while inside the third leg low aspect-ratio cylindrical pin fins are arranged in a staggered configuration to promote flow turbulence. Inside the third passage, the coolant is progressively discharged at the blade trailing edge and finally at the blade tip. The test model differs with respect to the real design only because there is no curvature due to the blade camber. Conversely, the correct stagger angle of the real blade with respect to the rotation axis is preserved. Experiments were performed for static and rotating conditions with engine similar conditions of Re=21000 and Ro=0.074, both defined at the channel inlet. Transient liquid crystal technique was used for the measurement of the heat transfer coefficient (HTC) on both pressure and suction sides internal surfaces of the channel. From the spatially resolved HTC maps available, it is possible to characterize the thermal performances of the whole passage and to highlight the effect of rotation.