Natali Bauer

Natali Bauer

Auto-generated profile, based on publicly available information

Natali Bauer

Faculty of Veterinary Medicine, Clinical Pathophysiology and Clinical Pathology, Justus-Liebig-University Gießen, Germany

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 November 2011 in Journal of Veterinary Diagnostic Investigation
Verified
Journal Article
Open access
PDF file
NBNatali Bauer
Natali Bauer
JNJulia Nakagawa
Julia Nakagawa
CDCathrin Dunker
Cathrin Dunker
KFKlaus Failing
Klaus Failing
AMAndreas Moritz
Andreas Moritz
The automated laser-based hematology analyzer Sysmex XT-2000 iV™ providing a complete blood cell count (CBC) and 5-part differential has been introduced in large veterinary laboratories. The aim of the current study was to determine precision, linearity, and accuracy of the Sysmex analyzer. Reference method for the accuracy study was the laser-based hematology analyzer ADVIA® 2120. For evaluation of accuracy, consecutive fresh blood samples from healthy and diseased cats ( n = 216), dogs ( n = 314), and horses ( n = 174) were included. A low intra-assay coefficient of variation (CV) of approximately 1% was seen for the CBC except platelet count (PLT). An intra-assay CV ranging between 2% and 5.5% was evident for the differential count except for feline and equine monocytes (7.7%) and horse eosinophils (15.7%). Linearity was excellent for white blood cell count (WBC), hematocrit value, red blood cell count (RBC), and PLT. For all evaluated species, agreement was excellent for WBC and RBC, with Spearman rank correlation coefficients (rs) ranging from >0.99 to 0.98. Hematocrit value correlated excellently in cats and dogs, whereas for horses, a good correlation was evident. A good correlation between both analyzers was seen in feline and equine PLT (rs = 0.89 and 0.92, respectively), whereas correlation was excellent for dogs (rs = 0.93). Biases were close to 0 except for mean corpuscular hemoglobin concentration (4.11 to −7.25 mmol/l) and canine PLT (57 × 109/l). Overall, the performance of the Sysmex analyzer was excellent and compared favorably with the ADVIA analyzer.

1 June 2016 in Experimental and Toxicologic Pathology
Verified
Journal Article
Closed access
MBMartina Bleyer
Martina Bleyer
CCChristoph Curths
Christoph Curths
FDFranziska Dahlmann
Franziska Dahlmann
JWJudy Wichmann
Judy Wichmann
NBNatali Bauer
Natali Bauer
EGEva Gruber-Dujardin
Eva Gruber-Dujardin