Nicholas W. F. Linton

Nicholas W. F. Linton

Auto-generated profile, based on publicly available information

Nicholas W. F. Linton

Department of Bioengineering, Imperial College London Hammersmith Hospital London UK

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 February 2023 in EP Europace
Verified
Journal Article
Open access
PDF file
NANadine Ali
Nadine Ali
AAAhran D Arnold
Ahran D Arnold
AMAlejandra A Miyazawa
Alejandra A Miyazawa
DKDaniel Keene
Daniel Keene
JCJi-Jian Chow
Ji-Jian Chow
ZWZachary I Whinnett
Zachary I Whinnett
Left bundle branch area pacing (LBBAP) is a promising method for delivering cardiac resynchronization therapy (CRT), but its relative physiological effectiveness compared with His bundle pacing (HBP) is unknown. We conducted a within-patient comparison of HBP, LBBAP, and biventricular pacing (BVP). Patients referred for CRT were recruited. We assessed electrical response using non-invasive mapping, and acute haemodynamic response using a high-precision haemodynamic protocol. Nineteen patients were recruited: 14 male, mean LVEF of 30%. Twelve had time for BVP measurements. All three modalities reduced total ventricular activation time (TVAT), (ΔTVATHBP -43 ± 14 ms and ΔTVATLBBAP −35 ± 20 ms vs. ΔTVATBVP −19 ± 30 ms, P = 0.03 and P = 0.1, respectively). HBP produced a significantly greater reduction in TVAT compared with LBBAP in all 19 patients (−46 ± 15 ms, −36 ± 17 ms, P = 0.03). His bundle pacing and LBBAP reduced left ventricular activation time (LVAT) more than BVP (ΔLVATHBP −43 ± 16 ms, P < 0.01 vs. BVP, ΔLVATLBBAP −45 ± 17 ms, P < 0.01 vs. BVP, ΔLVATBVP −13 ± 36 ms), with no difference between HBP and LBBAP (P = 0.65). Acute systolic blood pressure was increased by all three modalities. In the 12 with BVP, greater improvement was seen with HBP and LBBAP (6.4 ± 3.8 mmHg BVP, 8.1 ± 3.8 mmHg HBP, P = 0.02 vs. BVP and 8.4 ± 8.2 mmHg for LBBAP, P = 0.3 vs. BVP), with no difference between HBP and LBBAP (P = 0.8). HBP delivered better ventricular resynchronization than LBBAP because right ventricular activation was slower during LBBAP. But LBBAP was not inferior to HBP with respect to LV electrical resynchronization and acute haemodynamic response.

1 September 2019 in Heart Rhythm
Verified
Journal Article
Open access
NQNorman A. Qureshi
Norman A. Qureshi
SKSteven J. Kim
Steven J. Kim
CCChris Cantwell
Chris Cantwell
VAValtino X. Afonso
Valtino X. Afonso
WBWenjia Bai
Wenjia Bai
PLPhang Boon Lim
Phang Boon Lim
Bipolar electrogram voltage during sinus rhythm (VSR) has been used as a surrogate for atrial fibrosis in guiding catheter ablation of persistent atrial fibrillation (AF), but the fixed rate and wavefront characteristics present during sinus rhythm may not accurately reflect underlying functional vulnerabilities responsible for AF maintenance. The purpose of this study was determine whether, given adequate temporal sampling, the spatial distribution of mean AF voltage (VmAF) better correlates with delayed-enhancement magnetic resonance imaging (MRI-DE)-detected atrial fibrosis than VSR. AF was mapped (8 seconds) during index ablation for persistent AF (20 patients) using a 20-pole catheter (660 ± 28 points/map). After cardioversion, VSR was mapped (557 ± 326 points/map). Electroanatomic and MRI-DE maps were co-registered in 14 patients. The time course of VmAF was assessed from 1-40 AF cycles (∼8 seconds) at 1113 locations. VmAF stabilized with sampling >4 seconds (mean voltage error 0.05 mV). Paired point analysis of VmAF from segments acquired 30 seconds apart (3667 sites; 15 patients) showed strong correlation (r = 0.95; P <.001). Delayed enhancement (DE) was assessed across the posterior left atrial (LA) wall, occupying 33% ± 13%. VmAF distributions were (median [IQR]) 0.21 [0.14-0.35] mV in DE vs 0.52 [0.34-0.77] mV in non-DE regions. VSR distributions were 1.34 [0.65-2.48] mV in DE vs 2.37 [1.27-3.97] mV in non-DE. VmAF threshold of 0.35 mV yielded sensitivity of 75% and specificity of 79% in detecting MRI-DE compared with 63% and 67%, respectively, for VSR (1.8-mV threshold). CONCLUSION: The correlation between low-voltage and posterior LA MRI-DE is significantly improved when acquired during AF vs sinus rhythm. With adequate sampling, mean AF voltage is a reproducible marker reflecting the functional response to the underlying persistent AF substrate.

2 July 2025 in EP Europace
Verified
Journal Article
Open access
FSFrédéric Sacher
Frédéric Sacher
ASAndrea Sarkozy
Andrea Sarkozy
HPHelmut Purerfellner
Helmut Purerfellner
ASAlexandra Steyer
Alexandra Steyer
JLJonathan Lyne
Jonathan Lyne
PPPetr Peichl
Petr Peichl
Aims: The feasibility and safety of the lattice-tip catheter for ventricular arrhythmia (VA) ablation in humans remain largely unknown. This study aimed to assess feasibility, safety profile as well as patient outcomes after VA ablation with a lattice-tip catheter in a multicentre European registry. Methods and results: All 18 European centres using the AFFERA system in September 2024 agreed to participate. Clinical, procedural, and follow-up data (minimum 3 months) were systematically collected and analysed. A total of 126 patients (18% female; mean age 59 ± 16 years) underwent VA ablation using the lattice-tip catheter during the inclusion period. Ablation indications included ventricular tachycardia (VT) in 99, premature ventricular complexes (PVCs) in 23, and ventricular fibrillation (VF) in 4 patients. Major and minor acute complications were observed in 7 (6%) and 18 (14%) procedures, respectively. They included thrombo-embolic event (n = 2), major bleeding (n = 2), ventricular fibrillation induction (n = 1), tamponade due to epicardial access (n = 1), and cardiogenic shock due to prolonged VT mapping (n = 1). Within the first month post-procedure, three patients died [from multi-organ failure (n = 2) and sepsis (n = 1)], two had worsening heart failure, one myocardial infarction, one sepsis, and one major gastro-intestinal bleeding. After a mean follow-up of 5.6 ± 3.7 months, absence of recurrence was 78% for PVC, 70% for VT, and 100% for VF. Conclusion: In this complex population with refractory VA, ablation using the lattice-tip catheter appears feasible and relatively safe. In the absence of large, randomized trials, exhaustive registry is of key importance to ensure safety and efficacy of new catheter technologies.

5 October 2023 in EP Europace
Verified
Journal Article
Open access
PDF file
NANadine Ali
Nadine Ali
KSKhulat Saqi
Khulat Saqi
AAAhran D Arnold
Ahran D Arnold
AMAlejandra A Miyazawa
Alejandra A Miyazawa
DKDaniel Keene
Daniel Keene
ZWZachary I Whinnett
Zachary I Whinnett
Left bundle branch pacing (LBBP) can deliver physiological left ventricular activation, but typically at the cost of delayed right ventricular (RV) activation. Right ventricular activation can be advanced through anodal capture, but there is uncertainty regarding the mechanism by which this is achieved, and it is not known whether this produces haemodynamic benefit. We recruited patients with LBBP leads in whom anodal capture eliminated the terminal R-wave in lead V1. Ventricular activation pattern, timing, and high-precision acute haemodynamic response were studied during LBBP with and without anodal capture. We recruited 21 patients with a mean age of 67 years, of whom 14 were males. We measured electrocardiogram timings and haemodynamics in all patients, and in 16, we also performed non-invasive mapping. Ventricular epicardial propagation maps demonstrated that RV septal myocardial capture, rather than right bundle capture, was the mechanism for earlier RV activation. With anodal capture, QRS duration and total ventricular activation times were shorter (116 ± 12 vs. 129 ± 14 ms, P < 0.01 and 83 ± 18 vs. 90 ± 15 ms, P = 0.01). This required higher outputs (3.6 ± 1.9 vs. 0.6 ± 0.2 V, P < 0.01) but without additional haemodynamic benefit (mean difference −0.2 ± 3.8 mmHg compared with pacing without anodal capture, P = 0.2). Left bundle branch pacing with anodal capture advances RV activation by stimulating the RV septal myocardium. However, this requires higher outputs and does not improve acute haemodynamics. Aiming for anodal capture may therefore not be necessary.

1 January 2022 in Radiology: Artificial Intelligence
Verified
Journal Article
Closed access
SZSameer Zaman
Sameer Zaman
CPCamille Petri
Camille Petri
KVKavitha Vimalesvaran
Kavitha Vimalesvaran
JHJames Howard
James Howard
ABAnil Bharath
Anil Bharath
NLNick Linton
Nick Linton
A semisupervised natural language processing (NLP) algorithm, based on bidirectional transformers, accurately categorized diagnoses from cardiac MRI text of radiology reports for the labeling of MR... Purpose To assess whether the semisupervised natural language processing (NLP) of text from clinical radiology reports could provide useful automated diagnosis categorization for ground truth label...

6 June 2023 in JMIR Nursing
Verified
Journal Article
Open access
AAAlice Auton
Alice Auton
SZSameer Zaman
Sameer Zaman
YPYorissa Padayachee
Yorissa Padayachee
JSJack W Samways
Jack W Samways
NQNicholas M Quaife
Nicholas M Quaife
CPCarla Plymen
Carla Plymen
Background: Community-based management by heart failure specialist nurses (HFSNs) is key to improving self-care in heart failure with reduced ejection fraction. Remote monitoring (RM) can aid nurse-led management, but in the literature, user feedback evaluation is skewed in favor of the patient rather than nursing user experience. Furthermore, the ways in which different groups use the same RM platform at the same time are rarely directly compared in the literature. We present a balanced semantic analysis of user feedback from patient and nurse perspectives of Luscii, a smartphone-based RM strategy combining self-measurement of vital signs, instant messaging, and e-learning. Objective: This study aims to (1) evaluate how patients and nurses use this type of RM (usage type), (2) evaluate patients’ and nurses’ user feedback on this type of RM (user experience), and (3) directly compare the usage type and user experience of patients and nurses using the same type of RM platform at the same time. Methods: We performed a retrospective usage type and user experience evaluation of the RM platform from the perspective of both patients with heart failure with reduced ejection fraction and the HFSNs using the platform to manage them. We conducted semantic analysis of written patient feedback provided via the platform and a focus group of 6 HFSNs. Additionally, as an indirect measure of tablet adherence, self-measured vital signs (blood pressure, heart rate, and body mass) were extracted from the RM platform at onboarding and 3 months later. Paired 2-tailed t tests were used to evaluate differences between mean scores across the 2 timepoints. Results: A total of 79 patients (mean age 62 years; 35%, 28/79 female) were included. Semantic analysis of usage type revealed extensive, bidirectional information exchange between patients and HFSNs using the platform. Semantic analysis of user experience demonstrates a range of positive and negative perspectives. Positive impacts included increased patient engagement, convenience for both user groups, and continuity of care. Negative impacts included information overload for patients and increased workload for nurses. After the patients used the platform for 3 months, they showed significant reductions in heart rate (P=.004) and blood pressure (P=.008) but not body mass (P=.97) compared with onboarding. Conclusions: Smartphone-based RM with messaging and e-learning facilitates bilateral information sharing between patients and nurses on a range of topics. Patient and nurse user experience is largely positive and symmetrical, but there are possible negative impacts on patient attention and nurse workload. We recommend RM providers involve patient and nurse users in platform development, including recognition of RM usage in nursing job plans.