Thomas Kaufmann

Thomas Kaufmann

Auto-generated profile, based on publicly available information

Thomas Kaufmann

Department of Anesthesiology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 December 2019 in Acta Anaesthesiologica Scandinavica
Verified
Journal Article
Open access
PDF file
BKBritt E. Keuning
Britt E. Keuning
TKThomas Kaufmann
Thomas Kaufmann
RWRenske Wiersema
Renske Wiersema
AGAnders Granholm
Anders Granholm
VPVille Pettilä
Ville Pettilä
HCHEALICS consortium
HEALICS consortium
Background: Mortality prediction models are applied in the intensive care unit (ICU) to stratify patients into different risk categories and to facilitate benchmarking. To ensure that the correct prediction models are applied for these purposes, the best performing models must be identified. As a first step, we aimed to establish a systematic review of mortality prediction models in critically ill patients.Methods: Mortality prediction models were searched in four databases using the following criteria: developed for use in adult ICU patients in high‐income countries, with mortality as primary or secondary outcome. Characteristics and performance measures of the models were summarized. Performance was presented in terms of discrimination, calibration and overall performance measures presented in the original publication.Results: In total, 43 mortality prediction models were included in the final analysis. In all, 15 models were only internally validated (35%), 13 externally (30%) and 10 (23%) were both internally and externally validated by the original researchers. Discrimination was assessed in 42 models (98%). Commonly used calibration measures were the Hosmer‐Lemeshow test (60%) and the calibration plot (28%). Calibration was not assessed in 11 models (26%). Overall performance was assessed in the Brier score (19%) and the Nagelkerke's R2 (4.7%).Conclusions: Mortality prediction models have varying methodology, and validation and performance of individual models differ. External validation by the original researchers is often lacking and head‐to‐head comparisons are urgently needed to identify the best performing mortality prediction models for guiding clinical care and research in different settings and populations.

13 January 2020 in Critical Care
Verified
Journal Article
Open access
PDF file
SGSICS Study Group
SICS Study Group
ECEline G. M. Cox
Eline G. M. Cox
GKGeert Koster
Geert Koster
ABAidan Baron
Aidan Baron
TKThomas Kaufmann
Thomas Kaufmann
IHIwan C. C. van der Horst
Iwan C. C. van der Horst
Background: In critically ill patients, auscultation might be challenging as dorsal lung fields are difficult to reach in supine-positioned patients, and the environment is often noisy. In recent years, clinicians have started to consider lung ultrasound as a useful diagnostic tool for a variety of pulmonary pathologies, including pulmonary edema. The aim of this study was to compare lung ultrasound and pulmonary auscultation for detecting pulmonary edema in critically ill patients. Methods: This study was a planned sub-study of the Simple Intensive Care Studies-I, a single-center, prospective observational study. All acutely admitted patients who were 18 years and older with an expected ICU stay of at least 24 h were eligible for inclusion. All patients underwent clinical examination combined with lung ultrasound, conducted by researchers not involved in patient care. Clinical examination included auscultation of the bilateral regions for crepitations and rhonchi. Lung ultrasound was conducted according to the Bedside Lung Ultrasound in Emergency protocol. Pulmonary edema was defined as three or more B lines in at least two (bilateral) scan sites. An agreement was described by using the Cohen κ coefficient, sensitivity, specificity, negative predictive value, positive predictive value, and overall accuracy. Subgroup analysis were performed in patients who were not mechanically ventilated. Results: The Simple Intensive Care Studies-I cohort included 1075 patients, of whom 926 (86%) were eligible for inclusion in this analysis. Three hundred seven of the 926 patients (33%) fulfilled the criteria for pulmonary edema on lung ultrasound. In 156 (51%) of these patients, auscultation was normal. A total of 302 patients (32%) had audible crepitations or rhonchi upon auscultation. From 130 patients with crepitations, 86 patients (66%) had pulmonary edema on lung ultrasound, and from 209 patients with rhonchi, 96 patients (46%) had pulmonary edema on lung ultrasound. The agreement between auscultation findings and lung ultrasound diagnosis was poor (κ statistic 0.25). Subgroup analysis showed that the diagnostic accuracy of auscultation was better in non-ventilated than in ventilated patients. Conclusion: The agreement between lung ultrasound and auscultation is poor. Trial registration: NCT02912624. Registered on September 23, 2016.

31 January 2019 in Intensive Care Medicine
Verified
Journal Article
Open access
PDF file
SGSICS Study Group
SICS Study Group
BHBart Hiemstra
Bart Hiemstra
GKGeert Koster
Geert Koster
RWRenske Wiersema
Renske Wiersema
YHYoran M. Hummel
Yoran M. Hummel
IHIwan C. C. van der Horst
Iwan C. C. van der Horst
Clinical examination is often the first step to diagnose shock and estimate cardiac index. In the Simple Intensive Care Studies-I, we assessed the association and diagnostic performance of clinical signs for estimation of cardiac index in critically ill patients.

6 July 2018 in Acta Anaesthesiologica Scandinavica
Verified
Journal Article
Closed access
PDF file
TKThomas Kaufmann
Thomas Kaufmann
RCRamon P. Clement
Ramon P. Clement
TSThomas W. L. Scheeren
Thomas W. L. Scheeren
BSBernd Saugel
Bernd Saugel
FKFrederik Keus
Frederik Keus
IHIwan C. C. van der Horst
Iwan C. C. van der Horst

8 January 2020 in The Ultrasound Journal
Verified
Journal Article
Open access
PDF file
GKGeert Koster
Geert Koster
TKThomas Kaufmann
Thomas Kaufmann
BHBart Hiemstra
Bart Hiemstra
RWRenske Wiersema
Renske Wiersema
MVMadelon E. Vos
Madelon E. Vos
IHIwan C. C. van der Horst
Iwan C. C. van der Horst
Background: Critical care ultrasonography (CCUS) is increasingly applied also in the intensive care unit (ICU) and performed by non-experts, including even medical students. There is limited data on the training efforts necessary for novices to attain images of sufficient quality. There is no data on medical students performing CCUS for the measurement of cardiac output (CO), a hemodynamic variable of importance for daily critical care. Objective: The aim of this study was to explore the agreement of cardiac output measurements as well as the quality of images obtained by medical students in critically ill patients compared to the measurements obtained by experts in these images. Methods: In a prospective observational cohort study, all acutely admitted adults with an expected ICU stay over 24 h were included. CCUS was performed by students within 24 h of admission. CCUS included the images required to measure the CO, i.e., the left ventricular outflow tract (LVOT) diameter and the velocity time integral (VTI) in the LVOT. Echocardiography experts were involved in the evaluation of the quality of images obtained and the quality of the CO measurements. Results: There was an opportunity for a CCUS attempt in 1155 of the 1212 eligible patients (95%) and in 1075 of the 1212 patients (89%) CCUS examination was performed by medical students. In 871 out of 1075 patients (81%) medical students measured CO. Experts measured CO in 783 patients (73%). In 760 patients (71%) CO was measured by both which allowed for comparison; bias of CO was 0.0 L min −1 with limits of agreement of − 2.6 L min −1 to 2.7 L min −1 . The percentage error was 50%, reflecting poor agreement of the CO measurement by students compared with the experts CO measurement. Conclusions: Medical students seem capable of obtaining sufficient quality CCUS images for CO measurement in the majority of critically ill patients. Measurements of CO by medical students, however, had poor agreement with expert measurements. Experts remain indispensable for reliable CO measurements. Trial registration Clinicaltrials.gov; http://www.clinicaltrials.gov ; registration number NCT02912624

1 December 2021 in Journal of Clinical Anesthesia
Verified
Journal Article
Closed access
EWEric E.C. de Waal
Eric E.C. de Waal
MFMichael Frank
Michael Frank
TSThomas W.L. Scheeren
Thomas W.L. Scheeren
TKThomas Kaufmann
Thomas Kaufmann
DBDianne de Korte-De Boer
Dianne de Korte-De Boer
WBWolfgang Buhre
Wolfgang Buhre