Congenital ectopia lentis (CEL) usually leads to refractive error and may influence the axial length development. But few investigations have reported patient demographics and the distribution of axial length (AL) before surgery in Chinese pediatric patients with CEL. To describe the distribution of AL before surgery in CEL patients and its relationship with patients’ demographics, such as age, Marfan syndrome, sex, and laterality. This retrospective study reviewed 306 CEL patients from January 1, 2006 to December 31, 2015. One eye was randomly selected from each patient if both eyes were EL. The influences of Marfan syndrome, sex, and laterality to AL in different age subgroups were evaluated and compared. The differences of the AL between groups were assessed using the student t test or paired t-test. P-values less than 0.05 were considered statistically significant. Two hundred forty-seven eyes were enrolled. 58.3% of all the patients had binoculus EL, 70% of all the patients were male and 36% of all the patients were diagnosed with Marfan syndrome. The mean AL of EL patients was 25.1 ± 2.5 mm. There was no statistical difference in the AL between patients with and without Marfan syndrome, and in the AL between male and female patients. There was statistical difference in AL between the EL-affected eye and the unaffected eye in monocular EL patients younger than 12 years old. This study suggests that AL can be influenced by CEL, but the influence of CEL may be reduced after the age of 12 years old, which will likely provide a useful reference when considering the most appropriate time of surgery.
Purpose: To investigate the characteristics of foveal microvasculature in children with Marfan syndrome (MFS). Methods: Ninety eyes from 45 MFS patients and 76 eyes from 38 healthy individuals of age-matched, sex-matched, and axial length-matched were enrolled. Characteristics of the superficial capillary plexus including the vessel density, perfusion density, and foveal avascular zone were analyzed by optical coherence tomography angiography. Results: The vessel density and the circularity index of the foveal avascular zone were significantly decreased in the MFS group compared with the controls (P = 0.017 and P = 0.004 respectively). In MFS group, the central vessel density (P = 0.003) and perfusion density (P = 0.001) were negatively correlated with the best-corrected visual acuity. The foveal avascular zone area was correlated with the aortic diameters (P = 0.001) and the paratemporal perfusion density was correlated with the ejection fraction (P = 0.003). Moreover, the paratemporal perfusion density and the circularity index of foveal avascular zone were found to be correlated with the aortic Z-score (P < 0.001 and P = 0.003 respectively). Conclusion: Retinal microvascular decrease and its correlation with best-corrected visual acuity and cardiac functions were observed in the MFS group. The optical coherence tomography angiography may help to characterize the underlying pathophysiology features of MFS and enable early detection and prevention of vascular changes in MFS.
Purpose. The purpose of this study was to quantify the characteristics of the tilt and decentration of the IOL after trans-scleral suture fixation surgery in congenital ectopia lentis (CEL) patients. Methods. The clinical characteristics of 70 CEL patients at Zhongshan Ophthalmic Center in China were retrospectively analyzed. The tilt and decentration of intraocular lens (IOL) were measured by using a Pentacam and compared between different axial length (AL) subgroups. The correlation between IOL tilt, decentration, and ocular characteristics was investigated using Spearman’s correlation analysis. Results. The postoperative IOL position of CEL patients was mainly located nasally inferiorly. The average tilt of the IOL in CEL patients was less than 7° (for temporal: 2.21 ± 1.53°, for nasal: −1.84 ± 2.04°, for superior: 2.22 ± 2.18°, and for inferior: −1.70 ± 1.62°), and the average decentration of the IOL in CEL patients was larger than 0.4 mm (for temporal: 0.49 ± 0.38 mm, for nasal: −0.69 ± 0.46 mm, for superior: 0.72 ± 0.58 mm, and for inferior: −0.68 ± 0.54 mm). The decentration of CEL patients in the AL ≥ 26 subgroup was greater than those with AL < 24 mm and AL 24 to 26 mm subgroups (for superior: 0.72 ± 0.28 mm vs. 0.46 ± 0.25 mm and 0.48 ± 0.22 mm, all ; for inferior: -0.94 ± 0.56 mm vs. −0.44 ± 0.26 mm and -0.44 ± 0.46 mm, all ). IOL decentration was positively correlated with AL (for superior: r = 0.44, ; for inferior: r = 0.54, ). IOL tilt was positively correlated with AL on the superior side (r = 0.38, ). Conclusions. The extent of IOL decentration after trans-scleral suture fixation was great in CEL patients, and the IOL decentration in CEL patients was significantly associated with AL.