23 January 2019 in IEEE Robotics and Automation Letters
This paper presents a force observer that estimates the external interaction forces from the measured joint position and joint actuation for a class of robotic manipulators. This is done without an explicit (physical) force or torque sensor, through an extended state observer (ESO) assuming a known model of the dynamics of the manipulator. It is designed to be capable of estimating relatively fast time-varying external forces. The main result shows that the proposed ESO is theoretically able to estimate unknown time-varying external forces to an arbitrary accuracy for any initial condition starting in a given compact set. Simulation results demonstrate the effectiveness of the proposed ESO. Moreover, first experimental evaluations with a healthy subject and a post-stroke patient on a rehabilitation robotic platform show the feasibility of the approach in this context and highlight the importance of the quality of the dynamic model.
9 December 2022 in Journal of NeuroEngineering and Rehabilitation
Background: Spasticity is defined as “a motor disorder characterised by a velocity dependent increase in tonic stretch reflexes (muscle tone) with exaggerated tendon jerks”. It is a highly prevalent condition following stroke and other neurological conditions. Clinical assessment of spasticity relies predominantly on manual, non-instrumented, clinical scales. Technology based solutions have been developed in the last decades to offer more specific, sensitive and accurate alternatives but no consensus exists on these different approaches. Method: A systematic review of literature of technology-based methods aiming at the assessment of spasticity was performed. The approaches taken in the studies were classified based on the method used as well as their outcome measures. The psychometric properties and usability of the methods and outcome measures reported were evaluated. Results: 124 studies were included in the analysis. 78 different outcome measures were identified, among which seven were used in more than 10 different studies each. The different methods rely on a wide range of different equipment (from robotic systems to simple goniometers) affecting their cost and usability. Studies equivalently applied to the lower and upper limbs (48% and 52%, respectively). A majority of studies applied to a stroke population (N = 79). More than half the papers did not report thoroughly the psychometric properties of the measures. Analysis identified that only 54 studies used measures specific to spasticity. Repeatability and discriminant validity were found to be of good quality in respectively 25 and 42 studies but were most often not evaluated (N = 95 and N = 78). Clinical validity was commonly assessed only against clinical scales (N = 33). Sensitivity of the measure was assessed in only three studies. Conclusion: The development of a large diversity of assessment approaches appears to be done at the expense of their careful evaluation. Still, among the well validated approaches, the ones based on manual stretching and measuring a muscle activity reaction and the ones leveraging controlled stretches while isolating the stretch-reflex torque component appear as the two promising practical alternatives to clinical scales. These methods should be further evaluated, including on their sensitivity, to fully inform on their potential.
27 February 2018 in IEEE Robotics and Automation Letters
In rehabilitation for neurological injuries, gravity compensation or deweighting of the upper limb is often performed, as it allows patients with limited muscle activities to realize movements. Deweighting cancels the gravitational effect of the human arm allowing the available muscle forces to produce acceleration, and thus movement of the arm. In robotic devices designed for rehabilitation, deweighting is performed by applying forces to the arm, either joint-by-joint (e.g., with exoskeletons) or at a single point (e.g., with end-effector-based manipulanda). This paper formulates the gravity compensation strategy for spatial (three-dimensional) manipulanda, considers the effect of the force applied by the robotic device on the generalized dynamics of the upper limb and critically evaluates the advantages and limitations of this approach. Additionally, the proposed strategy is validated on the EMU robot, designed with the emphasis on its dynamically transparent mechanical transmission to allow an impedance control approach. The configuration of the EMU robot used in this letter only has 3 degrees of actuation, making it underactuated with respect to the task of regulating a human arm up to the wrist modeled with 4 degrees of freedom. The underactuation resulted in an uncompensated gravity induced moment about the swivel angle axis, which is a line connecting the shoulder and wrist points of the human arm. The experimental validation demonstrates the effectiveness of the proposed gravity compensation technique in cancelling the effect of gravity on the user's arm.
1 July 2020 in Disability and Rehabilitation: Assistive Technology
Purpose: Despite their promise to increase therapy intensity in neurorehabilitation, robotic devices have not yet seen mainstream adoption. Whilst there are a number of contributing factors, it is obvious that the treating clinician should have a clear understanding of the objectives and limitations of robotic device use. This study sought to explore how devices can be developed to support a clinician in providing clinical best practice. Methods and Materials: A user-centred design study of a robotic device was conducted, involving build-then-use iterations, where successive iterations are built based on feedback from the use cycle. This work reports results of an analysis of qualitative and quantitative data describing the use of the robotic device in the clinical sessions, and from a focus group with the treating clinicians. Results and Conclusions: The data indicated that use of the device did not result in patient goal-setting and may have resulted in poor movement quality. Therapists expected a higher level of autonomy from the robotic device, and this may have contributed to the above problems. These problems can and should be addressed through modification of both the study design and device to provide more explicit instructions to promote clinical best practice.
12 July 2021 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Recent studies have shown that motor adaptation is an optimisation process on both kinematic error and effort. This work aims to induce a motor adaption in an experimental setup solely relying on the effort without any explicit kinematic error. In this experiment, the intervention space and adaptation space are decoupled: while the force field only applies to the hand linear velocity, the adaptation is expected to happen in the arm joint null space (i.e. the swivel angle). The primary hypothesis is that such an effort-based force field can induce a movement pattern change in an indirect manner. Secondarily, assuming that this adaptation may be further promoted through subtle prompts to explore the cost space, a variation of the approach with a progressive goal is also tested. Twenty naive subjects were allocated into two groups with slightly different implementations of the force field: one with a Constant Goal (CG) and another one with a Progressively changing Goal (PG). Subjects were asked to perform reaching tasks while attached to a 3D manipulandum. During the intervention, the device applied a resistive viscous force at the subject's hand as a function of the subject's swivel angle to encourage an increase of the latter. Significant increases of the swivel angle of 4.9° and 6.3° were observed for the CG and the PG groups respectively. This result confirms the feasibility of inducing motor adaptation in the redundant joint space by providing a task space intervention without explicit error feedback.
28 February 2025 in IEEE Transactions on Robotics
Haptic interaction is critical in physical Human-Robot Interaction (pHRI), given its wide applications in manufacturing, medical and healthcare, and various industry tasks. A stable haptic interface is always needed while the human operator interacts with the robot. Passivity-based approaches have been widely utilised in the control design as a sufficient condition for stability. However, it is a conservative approach which therefore sacrifices performance to maintain stability. This paper proposes a novel concept to characterise an ultimately passive system, which can achieve the boundedness of the energy in the steady-state. A so-called Ultimately Passive Controller (UPC) is then proposed. This algorithm switches the system between a nominal mode for keeping desired performance and a conservative mode when needed to remain stable. An experimental evaluation on two robotic systems, one admittance-based and one impedance-based, demonstrates the potential interest of the proposed framework compared to existing approaches. The results demonstrate the possibility of UPC in finding a more aggressive trade-off between haptic performance and system stability, while still providing a stability guarantee.