30 December 2024 in Advanced Materials
A systematic study of the impact of film thickness on the properties of thin Bi films is presented. To this end, epitaxial films of high quality have been grown on a Si (111) substrate with thicknesses ranging from 1.9 to 29.9 nm. Broadband optical spectroscopy reveals a notable decline in the optical dielectric constant and the absorption peak height as the film thickness decreases, alongside a shift of the absorption maximum to higher photon energies. Raman and pump‐probe spectroscopy show that the phonon mode frequencies increase upon decreasing film thickness, with the in‐plane mode frequency rising by 10% from the thickest to the thinnest sample. The X‐ray diffraction analysis reveals an increasing Peierls distortion for thinner films, explaining the observed property changes. Quantum chemical bonding analysis and density functional theory calculations show that the properties of thin bismuth are influenced by the interplay between electron localization and delocalization, characteristic of metavalently bonded solids. This study shows that for solids that utilize metavalent bonding, a thickness reduction leads to significant property changes. The effect can even be employed to tailor material properties without the need to change material stoichiometry.
20 July 2026 in Physical Review B
We report on antiferromagnetic resonance experiments in bulk tetragonal NaMnAs---a room-temperature antiferromagnetic semiconductor. Our results corroborate previous ab initio studies which propose that NaMnAs is an easy-axis antiferromagnet with the N\'eel vector oriented along the tetragonal axis. At $B=0$, we find a single antiferromagnetic resonance line at 7 meV and associate it with a doubly degenerate ($k=0$) magnon mode. Its energy softens considerably with increasing $T$, but remains clearly visible in the data up to room temperature. From the experimental data, we estimate the single-ion anisotropy of the Mn ions in NaMnAs in the range 0.1--0.2 meV, a value that is relatively large compared to other manganese-based antiferromagnets.
27 October 2026 in Physical Review B
Hard-x-ray C 1 s photoemission from monolayer graphene probes a regime in which nuclear recoil and intrinsic electronic asymmetry contribute on comparable energy scales to the observed spectral line shape. Here we combine experiment and modeling over the photon-energy range 0.8 – 8 keV to resolve this interplay quantitatively. A graphene-specific implementation of the Fujikawa-Takata cumulant formalism, based on an anisotropic vibrational density of states constrained by first-principles phonon calculations, captures the expected recoil scaling with photon energy and emission geometry but fails to reproduce the pronounced asymmetric tails of the measured spectra. To overcome this limitation, we introduce an explicit electronic convolution model in which a photon-energy-independent reference response, dominated by the electronic line shape and extracted from the low-recoil 0.8 keV data through a recoil-inclusive fit, is convolved with a phonon recoil kernel carrying the full dependence on photon energy and emission angle. This approach reproduces both the measured line-shape evolution and the observed peak shifts across the explored energy range without refitting the spectra at higher photon energies. The results show that recoil in graphene cannot be described by a baseline treatment in which the phonon recoil kernel is combined only with symmetric lifetime broadening, but must be treated together with the intrinsic many-body electronic response of the C 1 s line.
9 September 2026 in Physical Review Applied
We present a study of the energy resolution of transition-edge sensors (TESs) for the detection of electrons in the 100-eV kinetic energy range. The TES is a Ti-Au bilayer with an active area of ( 60 × 60 ) μ m 2 and a critical temperature of approximately 80 mK . The electron source is based on vertically aligned multiwall carbon nanotubes located inside the cryostat, with electrons generated via field emission. For electrons in the ( 92 – 99 ) eV kinetic energy range, we obtain a Gaussian energy resolution for fully absorbed electrons of ( 0.48 ± 0.04 ± 0.06 ) eV , where the first uncertainty is statistical and the second systematic. When considering the full-width at half-maximum of the peak of the signal amplitude distribution, the corresponding resolution is of ( 1.4 ± 0.2 ± 0.3 ) eV . The former represents an improvement of ( 47 – 60 ) % with respect to previous results and is mainly attributed to the reduction in the TES active area. The latter is instead an improvement of over a factor of 21 and is mainly due to the reduction in the emitting area of the electron source, which significantly suppresses electron back-scattering in proximity of the TES. These results represent a major milestone toward high-precision spectroscopy on low-energy electrons, which is a key objective for the PTOLEMY experiment.