Chad P. Ammar

Chad P. Ammar

Auto-generated profile, based on publicly available information

Chad P. Ammar

Department of Surgery, University of Kansas School of Medicine–Wichita, Wichita, KS, USA

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2015 in Journal of Vascular Surgery
Verified
Journal Article
Closed access
ACAmy Chartrain
Amy Chartrain
SLSebastian Larion
Sebastian Larion
SASadaf S. Ahanchi
Sadaf S. Ahanchi
CAChad P. Ammar
Chad P. Ammar
CBColin T. Brandt
Colin T. Brandt
JPJean M. Panneton
Jean M. Panneton

15 July 2020 in The Journal of Vascular Access
Verified
Journal Article
Closed access
PDF file
BSBlake Spitzer
Blake Spitzer
KKKevin Kirkland
Kevin Kirkland
JRJared Reyes
Jared Reyes
SHStephen D Helmer
Stephen D Helmer
CAChad Ammar
Chad Ammar
CSChivukula Subbarao
Chivukula Subbarao
This study examined the safety and efficacy of placing both a central venous dialysis catheter and a central venous catheter for infusion in the right internal jugular vein compared to only a central venous dialysis catheter. We conducted a retrospective chart review for all adult patients who underwent the placement of the right internal jugular dialysis catheter by a single surgeon. Patients were grouped based on whether they received a tunneled dual lumen dialysis catheter alone or in combination with a central venous infusion catheter in the right internal jugular vein. Catheter-related thrombosis, line infections, line malfunctions, pneumothorax, and need for line replacement were evaluated. There were 97 patients in the dialysis catheter and central venous infusion line group and 63 patients in the dialysis catheter only group. The two groups were not different with regard to age (62.1 ± 16.3 years vs 57.9 ± 17.6 years) and gender (47.4% male vs 55.6% male). No significant differences were found in the incidence of thrombosis (1.0 % vs 0.0%, p > 0.999), line infection (2.1% vs 0.0%, p = 0.519), or line malfunctions (2.1% vs 0.0%, p = 0.516) in patients who did or did not have a central venous infusion catheter placed concomitantly with the dialysis catheter, respectively. No patients in either group had a pneumothorax. Although not currently utilized with frequency, these preliminary data indicate that placing both a dual lumen dialysis catheter and central venous infusion catheter in the right internal jugular simultaneously could be a viable option.