Mohamed M.A. Mahfouz

Mohamed M.A. Mahfouz

Auto-generated profile, based on publicly available information

Mohamed M.A. Mahfouz

Electrical Power and Machines Department, Helwan University, Cairo, Egypt

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2016 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
PDF file
MMMohamed M.A. Mahfouz
Mohamed M.A. Mahfouz
MEMohamed A.H. El-Sayed
Mohamed A.H. El-Sayed
Smart grid (SG) containing clean distributed generation (DG) has gained intensive research for reliable digital protection against fault conditions. The main objective of this study is to develop and validate a fast and efficient fault detection and classification algorithm taking into account the dynamic behaviour of DG units. The proposed algorithm does not require additional measurements as it based only on the synchronised measured three‐phase currents through the communication facilities available in SG. The advanced communication technologies in SG are currently utilised for efficient and real‐time data transfer from the protective relays to the monitoring and protection centre. The transferred data are processed for fault diagnosing before taking the necessary trip actions. In the proposed algorithm, the statistical cross‐alienation coefficients are calculated for the measured current signals at sending and receiving ends of each feeder. Fault detection and classification process will be achieved taking into account the changes in the synchronised and discretised waveform of current signals within a movable window of (1/4 cycle). The proposed algorithm is tested on real system to detect and classify the different fault condition. The results indicated that the proposed technique is fast and reliable for SG digital protection schemes.

1 January 2014 in IET Renewable Power Generation
Verified
Journal Article
Open access
PDF file
MMM.M.A Mahfouz
M.M.A Mahfouz
MEMohamed A.H. El-Sayed
Mohamed A.H. El-Sayed
High penetration level of wind energy affects the generation profile of the power systems, which impose more stringent connection requirements of wind farms. The ability of wind power plant to remain connected during grid faults is very important to avoid cascaded outages because of power deficit. FACT devices are considered to be a key technology to accomplish these requirements. The implementation of three‐level inverter based on a static synchronous compensator (STATCOM) for the improvement of the ride‐through and stability of fixed speed wind farms is analysed here. This brings the challenges for system planner to determine the appropriate STATCOM rating. This study provides a simple approach to evaluate the STATCOM rating for voltage‐level regulation at the point of common coupling around its pre‐specified value. Vector current control is used as robust control to inject the required reactive power from STATCOM. This study emphasizes also on the analysis of torque speed curve to evaluate the induction generator speed limit and for defining the critical clearing time of the fault according to the selected STATCOM rating. Simulation results under fault conditions are performed to validate the enhancement of wind farm low‐voltage ride‐through capability and increasing the critical clearing time by installing STATCOM.

5 November 2010 in IET Generation, Transmission & Distribution
Verified
Journal Article
Closed access
MMM.E. Masoud
M.E. Masoud
MMM.M.A. Mahfouz
M.M.A. Mahfouz
In modern digital power system protection systems, statistical coefficients technique is recently used for fault analysis. An alienation technique is developed for faults detection and discrimination. The proposed technique is able to accurately identify the condition of phase(s) involved in all ten types of shunt faults that may occur in extra high-voltage transmission lines under different fault resistances, inception angle and loading levels. The proposed technique does not need any extra equipment as it depends only on the three line-currents measurements which are mostly available at the relay location. This technique is able to perform the fault detection, type and phase selection in about a half-cycle period. Thus, the proposed technique is well suited for implementation in digital protection schemes. The proposed methodology is applied for a part of 500 KV Egyptian network. Alternative transient program and MATLAB programs are used to implement the proposed technique.

1 June 2016 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
PDF file
MAMohamed M.A. Mahfouz Aly
Mohamed M.A. Mahfouz Aly
MEMohamed A.H. El-Sayed
Mohamed A.H. El-Sayed
Modern smart grid (SG) should efficiently accommodate the renewable resources such as wind energy under different operation conditions. High level of wind energy penetration into SG results in operation constraints to avoid any tripping out of wind generators from the grid during fault conditions. Therefore, following the fault occurrence, the utility has to restore power as quickly as possible. This requires accurate and efficient fault location algorithms to have appropriate action for rapid service restoration. This study presents two fault location algorithms taking into account the dynamic behaviour of wind farm generation. In the first conventional algorithm, fault location is estimated using the recorded voltage and current signals at one end of the line. While second algorithm is two‐end fault location based on the synchronised voltage and current signals from the line ends. Calculations are carried out in time domain within half cycle using movable windows for recorded signals. The obtained results of two‐end algorithm are superior and more accurate compared with the conventional one‐end fault location algorithm. This is attributed to SG facilities with modern communication links and data synchronisation technology. The proposed algorithms are tested through grid and wind farm simulations to justify their effectiveness.

5 November 2012 in IET Generation, Transmission & Distribution
Verified
Journal Article
Closed access
MEM.M. Eissa
M.M. Eissa
MMM.M.A. Mahfouz
M.M.A. Mahfouz
Traditional directional power and current protection requires the current and the voitage to be measured. The directional current protection equipment is only capable for tripping the faulty incomer. While the direction in which the fault occurs is detected by measuring the direction of current flow, or in other words the phase displacement between the current and voltage. This study introduces a directional protection technique with phase selection based on measuring the current only. The correlogram function principle is applied on two successive current cycles. The two cycles are based on the pre- and post-fault current signals. The ability to differentiate between a fault in one direction and others is obtained using the sign of correlogram coefficients while its magnitude is used to identify the faulted phase. A proposed directional relay characteristic with correlogram coefficients calculated pre- and during the fault are also introduced. Different cases of non-symmetrical faults have been studied on a real recorded fault data for 240-kV transmission system at the province of Alberta-Canada. The results showed that the proposed technique is simple and reliable not only to identify the fault direction but also to select the faulted phases.