Anton H. J. Koning

Anton H. J. Koning

Auto-generated profile, based on publicly available information

Anton H. J. Koning

Department of Pathology Erasmus MC University Medical Center Rotterdam the Netherlands

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2018 in Placenta
Verified
Journal Article
Closed access
MRMelek Rousian
Melek Rousian
MKMaria P.H. Koster
Maria P.H. Koster
AMAnnemarie G.M.G.J. Mulders
Annemarie G.M.G.J. Mulders
AKAnton H.J. Koning
Anton H.J. Koning
RSRégine P.M. Steegers-Theunissen
Régine P.M. Steegers-Theunissen
ESEric A.P. Steegers
Eric A.P. Steegers

20 April 2018 in European Journal of Clinical Nutrition
Verified
Journal Article
Closed access
PDF file
FPFrancesca Parisi
Francesca Parisi
MRMelek Rousian
Melek Rousian
R.P.M. Steegers-TheunissenR.P.M. Steegers-Theunissen
R.P.M. Steegers-Theunissen
AKAnton H. J. Koning
Anton H. J. Koning
SWSten P. Willemsen
Sten P. Willemsen
ESEric A. P. Steegers
Eric A. P. Steegers

19 March 2024 in Human Reproduction
Verified
Journal Article
Open access
PDF file
EVE S De Vos
E S De Vos
AMA G M G J Mulders
A G M G J Mulders
AKA H J Koning
A H J Koning
SWS P Willemsen
S P Willemsen
MRM Rousian
M Rousian
R.P.M. Steegers-TheunissenR.P.M. Steegers-Theunissen
R.P.M. Steegers-Theunissen
Is morphologic development of the first-trimester utero-placental vasculature associated with embryonic growth and development, fetal growth, and birth weight percentiles? Using the utero-placental vascular skeleton (uPVS) as a new imaging marker, this study reveals morphologic development of the first-trimester utero-placental vasculature is positively associated with embryonic growth and development, fetal growth, and birth weight percentiles. First-trimester development of the utero-placental vasculature is associated with placental function, which subsequently impacts embryonic and fetal ability to reach their full growth potential. The attribution of morphologic variations in the utero-placental vascular development, including the vascular structure and branching density, on prenatal growth remains unknown. This study was conducted in the VIRTUAL Placental study, a subcohort of 214 ongoing pregnancies, embedded in the prospective observational Rotterdam Periconception Cohort (Predict study). Women were included before 10 weeks gestational age (GA) at a tertiary referral hospital in The Netherlands between January 2017 and March 2018. We obtained three-dimensional power Doppler volumes of the gestational sac including the embryo and the placenta at 7, 9, and 11 weeks of gestation. Virtual Reality-based segmentation and a recently developed skeletonization algorithm were applied to the power Doppler volumes to generate the uPVS and to measure utero-placental vascular volume (uPVV). Absolute vascular morphology was quantified by assigning a morphologic characteristic to each voxel in the uPVS (i.e. end-, bifurcation-crossing-, or vessel point). Additionally, total vascular length (mm) was calculated. The ratios of the uPVS characteristics to the uPVV were calculated to determine the density of vascular branching. Embryonic growth was estimated by crown-rump length and embryonic volume. Embryonic development was estimated by Carnegie stages. Fetal growth was measured by estimated fetal weight in the second and third trimester and birth weight percentiles. Linear mixed models were used to estimate trajectories of longitudinal measurements. Linear regression analysis with adjustments for confounders was used to evaluate associations between trajectories of the uPVS and prenatal growth. Groups were stratified for conception method (natural/IVF-ICSI conceptions), fetal sex (male/female), and the occurrence of placenta-related complications (yes/no). Increased absolute vascular morphologic development, estimated by positive random intercepts of the uPVS characteristics, is associated with increased embryonic growth, reflected by crown-rump length (endpoints β = 0.017, 95% CI [0.009; 0.025], bifurcation points β = 0.012, 95% CI [0.006; 0.018], crossing points β = 0.017, 95% CI [0.008; 0.025], vessel points β = 0.01, 95% CI [0.002; 0.008], and total vascular length β = 0.007, 95% CI [0.003; 0.010], and similarly with embryonic volume and Carnegie stage, all P-values ≤ 0.01. Density of vascular branching was negatively associated with estimated fetal weight in the third trimester (endpoints: uPVV β = −94.972, 95% CI [−185.245; −3.698], bifurcation points: uPVV β = −192.601 95% CI [−360.532; −24.670]) and birth weight percentiles (endpoints: uPVV β = −20.727, 95% CI [−32.771; −8.683], bifurcation points: uPVV β −51.097 95% CI [−72.257; −29.937], and crossing points: uPVV β = −48.604 95% CI [−74.246; −22.961])), all P-values < 0.05. After stratification, the associations were observed in natural conceptions specifically. Although the results of this prospective observational study clearly demonstrate associations between first-trimester utero-placental vascular morphologic development and prenatal growth, further research is required before we can draw firm conclusions about a causal relationship. Our findings support the hypothesis that morphologic variations in utero-placental vascular development play a role in the vascular mechanisms involved in embryonic and fetal growth and development. Application of the uPVS could benefit our understanding of the pathophysiology underlying placenta-related complications. Future research should focus on the clinical applicability of the uPVS as an imaging marker for the early detection of fetal growth restriction. This research was funded by the Department of Obstetrics and Gynecology of the Erasmus MC, University Medical Centre, Rotterdam, The Netherlands. There are no conflicts of interest. Registered at the Dutch Trial Register (NTR6854).

19 September 2022 in Human Reproduction
Verified
Journal Article
Open access
PDF file
EVEline S de Vos
Eline S de Vos
AKAnton H J Koning
Anton H J Koning
R.P.M. Steegers-TheunissenR.P.M. Steegers-Theunissen
R.P.M. Steegers-Theunissen
SWSten P Willemsen
Sten P Willemsen
BRBas van Rijn
Bas van Rijn
AMAnnemarie G M G J Mulders
Annemarie G M G J Mulders
Can three-dimensional (3D) Power Doppler (PD) ultrasound and a skeletonization algorithm be used to assess first-trimester development of the utero-placental vascular morphology? The application of 3D PD ultrasonography and a skeletonization algorithm facilitates morphologic assessment of utero-placental vascular development in the first trimester and reveals less advanced vascular morphologic development in pregnancies with placenta-related complications than in pregnancies without placenta-related complications. Suboptimal development of the utero-placental vasculature is one of the main contributors to the periconceptional origin of placenta-related complications. The nature and attribution of aberrant vascular structure and branching patterns remain unclear, as validated markers monitoring first-trimester utero-placental vascular morphologic development are lacking. In this prospective observational cohort, 214 ongoing pregnancies were included before 10 weeks gestational age (GA) at a tertiary hospital between January 2017 and July 2018, as a subcohort of the ongoing Rotterdam Periconception Cohort study. By combining 3D PD ultrasonography and virtual reality, utero-placental vascular volume (uPVV) measurements were obtained at 7, 9 and 11 weeks GA. A skeletonization algorithm was applied to the uPVV measurements to generate the utero-placental vascular skeleton (uPVS), a network-like structure containing morphologic characteristics of the vasculature. Quantification of vascular morphology was performed by assigning a morphologic characteristic to each voxel in the uPVS (end-, vessel-, bifurcation- or crossing-point) and calculating total vascular network length. A Mann–Whitney U test was performed to investigate differences in morphologic development of the first-trimester utero-placental vasculature between pregnancies with and without placenta-related complications. Linear mixed models were used to estimate trajectories of the morphologic characteristics in the first trimester. All morphologic characteristics of the utero-placental vasculature increased significantly in the first trimester (P < 0.005). In pregnancies with placenta-related complications (n = 54), utero-placental vascular branching was significantly less advanced at 9 weeks GA (vessel points P = 0.040, bifurcation points P = 0.050, crossing points P = 0.020, total network length P = 0.023). Morphologic growth trajectories remained similar after adjustment for parity, conception mode, foetal sex and occurrence of placenta-related complications. The tertiary setting of this prospective observational study provides high internal, but possibly limited external, validity. Extrapolation of the study’s findings should therefore be addressed with caution. The uPVS enables assessment of morphologic development of the first-trimester utero-placental vasculature. Further investigation of this innovative methodology needs to determine its added value for the assessment of (patho-) physiological utero-placental vascular development. This research was funded by the Department of Obstetrics and Gynecology of the Erasmus MC, University Medical Centre, Rotterdam, The Netherlands. There are no conflicts of interest. Registered at the Dutch Trial Register (NTR6854).

14 August 2024 in Angiogenesis
Verified
Journal Article
Open access
PDF file
EVEline S. de Vos
Eline S. de Vos
ADA. H. Jan Danser
A. H. Jan Danser
AKAnton H. J. Koning
Anton H. J. Koning
SWSten P. Willemsen
Sten P. Willemsen
LMLotte E. van der Meeren
Lotte E. van der Meeren
AMAnnemarie G. M. G. J. Mulders
Annemarie G. M. G. J. Mulders
Objective (s): Circulating angiogenic factors are used for prediction of placenta-related complications, but their associations with first-trimester placental development is unknown. This study investigates associations between maternal angiogenic factors and utero-placental vascular volume (uPVV) and utero-placental vascular skeleton (uPVS) as novel imaging markers of volumetric and morphologic (branching) development of the first-trimester utero-placental vasculature. Methods: In 185 ongoing pregnancies from the VIRTUAL Placenta study, a subcohort of the ongoing prospective Rotterdam Periconception cohort, three-dimensional power Doppler ultrasounds of the placenta were obtained at 7–9–11 weeks gestational age (GA). The uPVV was measured as a parameter of volumetric development and reported the vascular quantity in cm3. The uPVS was generated as a parameter of morphologic (branching) development and reported the number of end-, bifurcation- crossing- or vessel points and total vascular length. At 11 weeks GA, maternal serum biomarkers suggested to reflect placental (vascular) development were assessed: placental growth factor (PlGF), soluble fms-like tyrosine kinase-1 (sFlt-1) and soluble endoglin (sEng). sFlt-1/PlGF and sEng/PlGF ratios were calculated. Multivariable linear regression with adjustments was used to estimate associations between serum biomarkers and uPVV and uPVS trajectories. Results: Serum PlGF was positively associated with uPVV and uPVS development (uPVV: β = 0.39, 95% CI = 0.15;0.64; bifurcation points: β = 4.64, 95% CI = 0.04;9.25; crossing points: β = 4.01, 95% CI = 0.65;7.37; total vascular length: β = 13.33, 95% CI = 3.09;23.58, all p-values < 0.05). sEng/PlGF ratio was negatively associated with uPVV and uPVS development. We observed no associations between sFlt-1, sEng or sFlt-1/PlGF ratio and uPVV and uPVS development. Conclusion(s): Higher first-trimester maternal serum PlGF concentration is associated with increased first-trimester utero-placental vascular development as reflected by uPVV and uPVS. Clinical trial registration number Dutch Trial Register NTR6854.

31 March 2025
Verified
Journal Article
Open access
WBWietske A P Bastiaansen
Wietske A P Bastiaansen
SKStefan Klein
Stefan Klein
BHBatoul Hojeij
Batoul Hojeij
EREleonora Rubini
Eleonora Rubini
AKAnton H J Koning
Anton H J Koning
MRMelek Rousian
Melek Rousian
Noninvasive volumetric measurements during the first trimester of pregnancy provide unique insight into human embryonic growth and development. However, current methods, such as semiautomatic (eg, virtual reality [VR]) or manual segmentation (eg, VOCAL) are not used in routine care due to their time-consuming nature, requirement for specialized training, and introduction of inter- and intrarater variability. This study aimed to address the challenges of manual and semiautomatic measurements, our objective is to develop an automatic artificial intelligence (AI) algorithm to segment the region of interest and measure embryonic volume (EV) and head volume (HV) during the first trimester of pregnancy. We used 3D ultrasound datasets from the Rotterdam Periconception Cohort, collected between 7 and 11 weeks of gestational age. We measured the EV in gestational weeks 7, 9 and 11, and the HV in weeks 9 and 11. To develop the AI algorithms for measuring EV and HV, we used nnU-net, a state-of-the-art segmentation algorithm that is publicly available. We tested the algorithms on 164 (EV) and 92 (HV) datasets, both acquired before 2020. The AI algorithm's generalization to data acquired in the future was evaluated by testing on 116 (EV) and 58 (HV) datasets from 2020. The performance of the model was assessed using the intraclass correlation coefficient (ICC) between the volume obtained using AI and using VR. In addition, 2 experts qualitatively rated both VR and AI segmentations for the EV and HV. We found that segmentation of both the EV and HV using AI took around a minute additionally, rating took another minute, hence in total, volume measurement took 2 minutes per ultrasound dataset, while experienced raters needed 5-10 minutes using a VR tool. For both the EV and HV, we found an ICC of 0.998 on the test set acquired before 2020 and an ICC of 0.996 (EV) and 0.997 (HV) for data acquired in 2020. During qualitative rating for the EV, a comparable proportion (AI: 42%, VR: 38%) were rated as excellent; however, we found that major errors were more common with the AI algorithm, as it more frequently missed limbs. For the HV, the AI segmentations were rated as excellent in 79% of cases, compared with only 17% for VR. We developed 2 fully automatic AI algorithms to accurately measure the EV and HV in the first trimester on 3D ultrasound data. In depth qualitative analysis revealed that the quality of the measurement for AI and VR were similar. Since automatic volumetric assessment now only takes a couple of minutes, the use of these measurements in pregnancy for monitoring growth and development during this crucial period, becomes feasible, which may lead to better screening, diagnostics, and treatment of developmental disorders in pregnancy.