1 June 2024 in European Heart Journal - Case Reports
Background: Fluoroscopy-guided catheter ablation has become the gold standard for treatment of cardiac arrhythmias. High resolution electro-anatomical mapping systems have become fundamental to perform these procedures. Recently, interventional cardiac magnetic resonance (iCMR) has been proposed as an alternative for fluoroscopy to guide atrial flutter ablations. The clinical experience with iCMR and dedicated three-dimensional mapping systems is growing. NorthStar is currently the first available vendor-neutral mapping system. Case summary: We performed a real-time CMR-guided cavotricuspid isthmus (CTI) catheter ablation (CA) on a 69-year-old man using a novel mapping system (NorthStar Mapping System, Imricor Medical Systems, MN, USA). Starting from the CMR imaging, a pre-rendered segmentation model was loaded on NorthStar and used to guide the catheters, display voltage and activation maps, show mapping and ablation points. NorthStar can also take full control of the CMR scanner (i.e. start/stop sequences for anatomical information, tissue characterization, and catheter visualization) and communicate with the recorder/stimulator system (Advantage-MR EP, Imricor Medical Systems, MN, USA). With comparable procedural time to standard fluoroscopy-guided CA, CTI bidirectional block was achieved, without any complication. Discussion: Using the NorthStar Mapping System, we managed to achieve a successful CMR-guided CTI ablation without any complication. Its further use should be explored, especially in more complex arrhythmias where a substrate-guided ablation is critical, as it could significantly improve results in terms of arrhythmia recurrence.
28 March 2024 in European Heart Journal - Case Reports
The prone position is recommended as supportive therapy in patients with moderate-to-severe acute respiratory distress syndrome (ARDS). However, little is known about prone position ventilation in patients with cardiogenic shock supported by extracorporeal membrane oxygenation (ECMO) plus Impella (ECPELLA) developing ARDS. A 66-year-old man with severe left ventricular dysfunction was admitted to a non-academic ECMO centre for a high-risk coronary artery bypass grafting. He developed post-cardiotomy shock needing ECMO support. To improve left ventricular unloading, an Impella was inserted 2 days later. One day later, he developed ARDS and needed prone position ventilation with ECPELLA in situ. After 4 weeks, he was discharged from the intensive care unit. Previous studies demonstrated that prone positioning could help avoid an additional venous cannula in veno-arterial ECMO patients, which is associated with mechanical complications. In this case, there was a promising role for unloading the left ventricle with Impella during veno-arterial ECMO and, for proning, the patient with cardiogenic shock developing ARDS during ECMO support without the need for an extra venous cannula.