1 June 2020 in KSCE Journal of Civil Engineering
The solution to the problem of corrosion of the steel bars in magnesium oxychloride cement concrete (MOCC) is to apply a coating that protects the steel. To investigate the coating’s long- term protective effect on the steel, a solution immersion accelerated corrosion test was carried out on coated reinforced MOCC for up to 2,160 days. Electrochemical tests were conducted every 90 days to measure the polarization curve and AC impedance during the steel bars’ corrosion process. Then, the corrosion current density that characterizes the corrosion of a coated steel bar was used as a degradation index, and the time to the coated steel bar’s corrosion was predicted based on the Wiener function. It was concluded that after 2,160 days of solution immersion, the coated steel bars’ corrosion current density was 0.063 µA·cm−2, indicating that the coating protected the steel bars in MOCC from corrosion well. Thdroughout the immersion process, the specimen’s corrosion current density showed a steady and increasing trend, and its polarization impedance showed a volatile growth trend. The degradation of the coated steel bars also obeyed the Wiener degradation process, and the bars reached a severely rusted state at 21,800d with a corrosion time of R0.6(t) is 10,650d.
1 January 2018 in Advances in Civil Engineering Materials
To predict the failure lifetime of reinforced concrete, a current accelerating corrosion test was performed on concrete by simulating the environment in an area with saline soil. To study the concrete’s process of deterioration under these conditions, this study selected the corrosion current density of the steel bars and the ultrasonic velocity of the concrete as the main factors in accelerated corrosion degradation. Then, by using the Weibull distribution function to model the degradation process, the study obtained the reliability function of the accelerated failure. The results showed that the corrosion current density of the steel bars and the ultrasonic velocity of concrete can be used as degradation factors of reinforced concrete, but the corrosion current density is more stable, which is propitious for modeling. Further, the Weibull distribution function can describe the durability degradation process of reinforced concrete effectively. Because of the high content of corrosive ions in saline soil, the reinforced concrete cover fails first.
1 January 2024 in Advances in Cement Research
In view of the difficulty of identifying internal micro corrosion-induced cracks in concrete and the poor accuracy of quantitative analysis, which results in inaccurate results regarding the law of formation of internal cracks, reinforced magnesium oxychloride cement concrete (RMOCC) was subjected to a galvanostatic acceleration test, and X-CT technology was combined with the support vector machines (SVM) identification algorithm and grey-level co-occurrence matrix (GLCM) theory. Using the SVM algorithm and GLCM theory, the internal average crack width of concrete and the contrast, correlation, angular second moment (ASM) and inverse difference moment (IDM), which characterise the change in slice texture information, were used as degradation parameters. Using the average internal crack width and IDM as the degradation index, a reliability degradation competition failure analysis was conducted to study RMOCC's law of internal crack formation. The results showed that the SVM algorithm had a greater than 95% accuracy in recognising cracks. In the entire corrosion-induced crack formation process, IDM and the average internal crack width values were consistent with the normal distribution. Through reliability degradation competition failure analysis between IDM and the average crack width value, the average crack width calculated with SVM is more suitable for the degradation analysis of internal corrosion-induced cracks in RMOCC.
6 December 2022 in KSCE Journal of Civil Engineering
The constant current energization accelerated test was carried out to study the effect of asphalt coating on delaying reinforcement corrosion and rust-induced cracks in coated reinforced magnesium oxychloride cement concrete (CRMOCC). CRMOCC with different degrees of damage was scanned by adopting X-ray computed tomography (X-CT) technology, and the spatial information of rust and rust-induced cracks were analyzed visually and quantitatively. In addition, Scanning Electron Microscope (SEM) was used to analyze the non-uniformity of rust-induced crack formation. The results showed that the corrosion amount of coated reinforcement after energization was only 81.6% of that of uncoated reinforcement. Besides, no crack no cracking was observed on CRMOCC after 480h’s energization, while the rust-induced crack of reinforced magnesium oxychloride cement concrete (RMOCC) was 0.11 mm. The coating reduced the potential of rust-induced crack formation such that only three areas in CRMOCC were cracked, while RMOCC had cracks in eight areas. This study also found that interface transition zone (ITZ) played a dominant role in the formation of rust-induced cracks. The surface crack width in CRMOCC had an exponential relation with the crack volume and it had a linear relation with the volume of corrosion products. Further, there was an exponential relation between the volume loss of the reinforcement and the formation of rust-induced cracks. The correlation between surface crack width, corrosion products volume, rust-induced cracks volume and steel volume can be described by quadric surface. Results by SEM analysis indicated that in the ITZ of CRMOCC, Mg and O elements were the two main elements in the hydration products that were loose and needle-like. Furthermore, Si and O elements were the dominant materials in the non-interface transition zone (NITZ), resulting in relatively dense hydration products.