14 January 2019 in Journal of Lightwave Technology
A novel subsea cable condition monitoring technique based on embedded optical fibre inside the cable is demonstrated. It is shown that a distributed optical fibre vibration sensor can be used to map dynamic strains all along the cable simultaneously. It is experimentally shown that such system can fully quantify the location and strain level at each point on the cable as a function of time for both abrupt impact and cyclical loading. The sensing system demonstrated a spatial and strain resolution of 1 ${m}$ and 4 ${\mu \epsilon}$ , respectively, over a 10 ${km}$ sensing range.
1 December 2019 in IEEE Transactions on Dielectrics and Electrical Insulation
2 February 2015 in IEEE Transactions on Power Delivery
CTCharlotte E. L. Thompson
The thermal performance of high-voltage submarine cables is controlled by the effectiveness of heat transfer through the sediments in which they are buried. This paper assesses the influence of sediment parameters on this heat transfer using finite-element simulations. Particular attention is paid to the role of convective heat transfer, with a method being developed to define installation scenarios where this may become significant. This paper shows that the permeability is the dominant factor and can have a significant impact on cable temperatures, even though it is typically neglected in conventional models.
13 November 2014 in IEEE Transactions on Power Delivery
It is considered that the present IEC 60287 standard overestimates the induced losses in SL-type armored cables, which are commonly used to connect offshore windfarms to the onshore grid. This paper addresses the issue through a series of equivalent-circuit models for the estimation of circulating-current, eddy-current, and armor losses in these cables. Finite-element models are used for further validation. Both the finite-element and the equivalent-circuit models use an equivalent-material representation of the armor layer, for which two calculation methods are developed. The results demonstrate clearly that the equation for armor loss in such cables as presently used in IEC standards is overly conservative.
30 January 2019 in IEEE Transactions on Power Delivery
Induced losses are a significant part of the total losses generated in HVAC cables. Presently, IEC 60287-1-1 is used to calculate the ratio of induced loss in a cable's metal sheath to its conductor loss (λ1), assuming uniform current density in both conductors and sheaths. Although this assumption is reasonable for smaller cables, it is questionable for larger cables in close proximity, such as three-core (3C) export cables in Offshore Wind Farm (OWF) projects. The effects of this non-uniform current density cannot be easily treated via a straightforward, purely analytical approach, since conductor currents are not effectively represented by linear ones in larger cables, while sheath currents are also unevenly distributed. The present study employs 2-D Finite Element (FE) models to evaluate how accurate the Standard method for calculating the λ1 factor is in cables with non-magnetic armor. Their validity is further enhanced by means of Filament Method. IEC 60287 appears to overestimate the temperature, particularly for larger conductor sizes, by up to 7°C (8%). Finally, suitable Reductive Factors are suggested which could improve the accuracy of the IEC method.