James A. Pilgrim

James A. Pilgrim

Auto-generated profile, based on publicly available information

James A. Pilgrim

Tony Davies High Voltage Laboratory, University of Southampton, Southampton, Hampshire United Kingdom of Great Britain and Northern Ireland SO17 1BJ

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 January 2019 in Journal of Lightwave Technology
Verified
Journal Article
Closed access
Ali MasoudiAli Masoudi
Ali Masoudi
JPJames A. Pilgrim
James A. Pilgrim
TNTrevor P. Newson
Trevor P. Newson
GBGilberto Brambilla
Gilberto Brambilla
A novel subsea cable condition monitoring technique based on embedded optical fibre inside the cable is demonstrated. It is shown that a distributed optical fibre vibration sensor can be used to map dynamic strains all along the cable simultaneously. It is experimentally shown that such system can fully quantify the location and strain level at each point on the cable as a function of time for both abrupt impact and cyclical loading. The sensing system demonstrated a spatial and strain resolution of 1 ${m}$ and 4 ${\mu \epsilon}$ , respectively, over a 10 ${km}$ sensing range.

12 July 2019 in Energies
Verified
Journal Article
Open access
PDF file
JWJohn Warnock
John Warnock
DMDavid McMillan
David McMillan
JPJames Pilgrim
James Pilgrim
SSSally Shenton
Sally Shenton
In the offshore wind industry, failures are often costlier than those experienced onshore. Through examination of the literature, it is clear that failures occurring in offshore transmission systems are not well documented. As a result of this, many developers and other parties involved in the planning processes associated with offshore wind farms will defer back to existing reliability metrics in the public domain. This article presents a review of European offshore wind farm transmission failures based on fusing information from multiple public domain sources. The results highlight both the spread of the reliability performance of these assets and the reliability performance over time. The results also reinforce the industry view that installation practices could lead to low reliability in the initial years of operation, resulting in increased repair costs and decreased revenue for wind farm owners and operators. The information collated in the review is also compared to metrics from across the literature to evaluate the difference in forecasted failure rates to those experienced within the industry. In general, it is found that the experienced failure rates are subject to a much higher spread in practice than those published until now.

1 December 2019 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
MHM. A. Hamdan
M. A. Hamdan
JPJ. A. Pilgrim
J. A. Pilgrim
PLP. L. Lewin
P. L. Lewin

2 February 2015 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
THTimothy J. Henstock
Timothy J. Henstock
JPJames A. Pilgrim
James A. Pilgrim
JDJustin K. Dix
Justin K. Dix
TGThomas M. Gernon
Thomas M. Gernon
CTCharlotte E. L. Thompson
Charlotte E. L. Thompson
The thermal performance of high-voltage submarine cables is controlled by the effectiveness of heat transfer through the sediments in which they are buried. This paper assesses the influence of sediment parameters on this heat transfer using finite-element simulations. Particular attention is paid to the role of convective heat transfer, with a method being developed to define installation scenarios where this may become significant. This paper shows that the permeability is the dominant factor and can have a significant impact on cable temperatures, even though it is typically neglected in conventional models.

13 November 2014 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
KGKevin F. Goddard
Kevin F. Goddard
JPJames A. Pilgrim
James A. Pilgrim
RCRichard Chippendale
Richard Chippendale
PLPual L. Lewin
Pual L. Lewin
It is considered that the present IEC 60287 standard overestimates the induced losses in SL-type armored cables, which are commonly used to connect offshore windfarms to the onshore grid. This paper addresses the issue through a series of equivalent-circuit models for the estimation of circulating-current, eddy-current, and armor losses in these cables. Finite-element models are used for further validation. Both the finite-element and the equivalent-circuit models use an equivalent-material representation of the armor layer, for which two calculation methods are developed. The results demonstrate clearly that the equation for armor loss in such cables as presently used in IEC standards is overly conservative.

30 January 2019 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
DCDimitrios Chatzipetros
Dimitrios Chatzipetros
JPJames A. Pilgrim
James A. Pilgrim
Induced losses are a significant part of the total losses generated in HVAC cables. Presently, IEC 60287-1-1 is used to calculate the ratio of induced loss in a cable's metal sheath to its conductor loss (λ1), assuming uniform current density in both conductors and sheaths. Although this assumption is reasonable for smaller cables, it is questionable for larger cables in close proximity, such as three-core (3C) export cables in Offshore Wind Farm (OWF) projects. The effects of this non-uniform current density cannot be easily treated via a straightforward, purely analytical approach, since conductor currents are not effectively represented by linear ones in larger cables, while sheath currents are also unevenly distributed. The present study employs 2-D Finite Element (FE) models to evaluate how accurate the Standard method for calculating the λ1 factor is in cables with non-magnetic armor. Their validity is further enhanced by means of Filament Method. IEC 60287 appears to overestimate the temperature, particularly for larger conductor sizes, by up to 7°C (8%). Finally, suitable Reductive Factors are suggested which could improve the accuracy of the IEC method.