21 January 2013 in Journal of Neural Engineering
Visual prosthetics is an expanding subfield of functional electrical stimulation which has gained increased interest recently in light of new advances in treatments and technology. These treatments and technology represent a major improvement over prior art, but are still subject to a host of limitations which are dependent on the manner in which one approaches the topic of visual prosthetics. These limitations pose new research challenges whose solutions are directly applicable to the well-being of blind individuals everywhere. In this review, we will outline and critically compare major current approaches to visual prosthetics, and in particular retinal prosthetics. Then, we will engage in an in-depth discussion of the limitations imposed by current technology, physics, and the underlying biology of the retina to highlight several of the challenges currently facing researchers.
1 March 2016 in Investigative Ophthalmology & Visual Science
Purpose: To investigate the efficacy of electric field shaping in modulating the extent and activation threshold in retinal neurostimulation. This study aims to quantify the interference of neighboring stimulation sites by assessing the shift in the activation threshold produced by a concomitant interfering stimulus. Methods: Electrical stimuli were applied to healthy retinae in a feline model (n = 4) using a 24-channel electrode array surgically implanted in the suprachoroidal space. A 96-channel penetrating electrode array was used for recording cortical responses to a number of stimulation paradigms. Data were analyzed offline. Concurrent monopolar and hexapolar stimuli were delivered at primary and interfering sites separated by up to 2.19 mm to evaluate electric cross-talk. The spike rate was fit to a sigmoidal curve to estimate the P50 threshold. The slope of the linear regression of the P50 value versus interfering current level was considered as a measure of cross-talk. Results: Concurrent monopolar stimulation produced a proportional drop in the P50 of approximately 20% of the interfering current level in presence of a primary monopolar and hexapolar stimulus. On the other hand, hexapolar interference did not alter activation thresholds at the primary site. Conclusions: Hexapolar stimulation reduces electric cross-talk between neighboring sites and represents a technique to reduce interference between individual stimulation sites. In contrast, concurrent monopolar stimulation produces a reduction of the activation threshold of stimuli delivered nearby. Thus, a single source of subthreshold monopolar charge injection can provide benefit in the form of significant threshold reduction simultaneously at multiple stimulation sites.
16 October 2018 in The Journal of Neuroscience
APAlexander N.J. Pietersen
+1
The koniocellular (K) layers of the primate dorsal lateral geniculate nucleus house a variety of visual receptive field types, not all of which have been fully characterized. Here we made single-cell recordings targeted to the K layers of diurnal New World monkeys (marmosets). A subset of recorded cells was excited by both increments and decrements of light intensity (on/off-cells). Histological reconstruction of the location of these cells confirmed that they are segregated to K layers; we therefore refer to these cells as K-on/off cells. The K-on/off cells show high contrast sensitivity, strong bandpass spatial frequency tuning, and their response magnitude is strongly reduced by stimuli larger than the excitatory receptive field (silent suppressive surrounds). Stationary counterphase gratings evoke unmodulated spike rate increases or frequency-doubled responses in K-on/off cells; such responses are largely independent of grating spatial phase. The K-on/off cells are not orientation or direction selective. Some (but not all) properties of K-on/off cells are consistent with those of local-edge-detector/impressed-by-contrast cells reported in studies of cat retina and geniculate, and broad-thorny ganglion cells recorded in macaque monkey retina. The receptive field properties of K-on/off cells and their preferential location in the ventral K layers (K1 and K2) make them good candidates for the direct projection from geniculate to extrastriate cortical area MT/V5. If so, they could contribute to visual information processing in the dorsal (“where” or “action”) visual stream.SIGNIFICANCE STATEMENTWe characterize cells in an evolutionary ancient part of the visual pathway in primates. The cells are located in the lateral geniculate nucleus (the main visual afferent relay nucleus), in regions called koniocellular layers that are known to project to extrastriate visual areas as well as primary visual cortex. The cells show high contrast sensitivity and rapid, transient responses to light onset and offset. Their properties suggest they could contribute to visual processing in the dorsal (“where” or “action”) visual stream.
25 November 2021 in Journal of Neural Engineering
Objective.Neuromodulation of visceral nerves is being intensively studied for treating a wide range of conditions, but effective translation requires increasing the efficacy and predictability of neural interface performance. Here we use computational models of rat visceral nerve to predict how neuroanatomical variability could affect both electrical stimulation and recording with an experimental planar neural interface.Approach.We developed a hybrid computational pipeline,VisceralNerveEnsembleRecording andStimulation (ViNERS), to couple finite-element modelling of extracellular electrical fields with biophysical simulations of individual axons. Anatomical properties of fascicles and axons in rat pelvic and vagus nerves were measured or obtained from public datasets. To validate ViNERS, we simulated pelvic nerve stimulation and recording with an experimental four-electrode planar array.Main results.Axon diameters measured from pelvic nerve were used to model a population of myelinated and unmyelinated axons and simulate recordings of electrically evoked single-unit field potentials (SUFPs). Across visceral nerve fascicles of increasing size, our simulations predicted an increase in stimulation threshold and a decrease in SUFP amplitude. Simulated threshold changes were dominated by changes in perineurium thickness, which correlates with fascicle diameter. We also demonstrated that ViNERS could simulate recordings of electrically-evoked compound action potentials (ECAPs) that were qualitatively similar to pelvic nerve recording made with the array used for simulation.Significance.We introduce ViNERS as a new open-source computational tool for modelling large-scale stimulation and recording from visceral nerves. ViNERS predicts how neuroanatomical variation in rat pelvic nerve affects stimulation and recording with an experimental planar electrode array. We show ViNERS can simulate ECAPS that capture features of our recordings, but our results suggest the underlying NEURON models need to be further refined and specifically adapted to accurately simulate visceral nerve axons.
1 September 2019 in NeuroImage
23 April 2023 in Advanced Healthcare Materials
Vagus nerve stimulation (VNS) has the potential to treat various peripheral dysfunctions, but the traditional cuff electrodes for VNS are susceptible to off‐target effects. Microelectrodes may enable highly selective VNS that can mitigate off‐target effects, but they suffer from the increased impedance. Recent studies on microelectrodes with non‐Euclidean geometries have reported higher energy efficiency in neural stimulation applications. These previous studies use electrodes with mm/cm‐scale dimensions, mostly targeted for myelinated fibers. This study evaluates fractal microelectrodes for VNS in a rodent model (N = 3). A thin‐film device with fractal and circle microelectrodes is fabricated to compare their neural stimulation performance on the same radial coordinate of the nerve. The results show that fractal microelectrodes can activate C‐fibers with up to 52% less energy (p = 0.012) compared to circle microelectrodes. To the best of the knowledge, this work is the first to demonstrate a geometric advantage of fractal microelectrodes for VNS in vivo.