Antonina V. Chernaya

Antonina V. Chernaya

Auto-generated profile, based on publicly available information

Antonina V. Chernaya

N. N. Petrov National Medical Research Center of Oncology

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 June 2020 in Tumors of female reproductive system
Verified
Journal Article
Open access
PDF file
VSV. F. Semiglazov
V. F. Semiglazov
ПКП. В. Криворотько
П. В. Криворотько
EZE. K. Zhiltsova
E. K. Zhiltsova
SKS. V. Kanaev
S. V. Kanaev
ETE. S. Trufanova
E. S. Trufanova
SNS. N. Novikov
S. N. Novikov
Biopsy of signal (sentinel) lymph nodes (LN) has been performed at the N.N. Petrov National Medical Research Oncology Center, Ministry of Health of Russia, for almost 20 years. In the first few years, contrast-visual method (1 % blue isosulfan and triphenyl methane control) was used in 640 patients with early (T1–2N0M0) breast cancer. In 150 patients from this cohort, standard axillary dissection was performed irrespectively of the results of signal (sentinel) biopsy. The rate of false positive responses varied between 4.6 and 6.6 %. Since 2012, radioisotope method of visualization of signal LN with intratumor administration of 99mТс-technephyte colloid particles has been used (in 708 patients with T1–3N0M0 breast cancer). This type of signal LN biopsy had the following diagnostic characteristics: sensitivity was 58.9 %, specificity was 96.2 %, diagnostic accuracy was 87.1 %.In parallel with this study, in 2016 a study of diagnostic accuracy and safety of biopsy of axillary LN after neoadjuvant systemic therapy was started. The study included 263 patients with T1N1–3M0, T2–3N0–3M0, T4N0–1M0 breast cancer. To evaluate clinical status of axillary LN, ultrasound, single-photon emission computed tomography, mammography at baseline and after completion of neoadjuvant chemotherapy ± targeted therapy (trastuzumab) were performed. In some patients, in the recent years a double method of signal LN labeling (radioisotope and fluorescent methods) was used.In patients with baseline cN+-status, the rate of false positive signal LN biopsy conclusions was 13.6 %, in patients with baseline cN0-status it was 7.7 %.The study of double contrast of axillary LN and targeted label of metastatic LN prior to neoadjuvant systemic therapy continues. In total, various modifications of biopsy of signal LN were performed in 2,000 patients with breast cancer.The study protocol was approved by the biomedical ethics committee of N.N. Petrov National Medical Research Oncology Center, Ministry of Health of Russia.All patients gave written informed consent to participate in the study.

5 August 2023 in Tumors of female reproductive system
Verified
Journal Article
Open access
PDF file
VPV. I. Pavlova
V. I. Pavlova
YBYu. A. Belaya
Yu. A. Belaya
AVA. Yu. Vorontsov
A. Yu. Vorontsov
APA. A. Prishchepov
A. A. Prishchepov
SKS. M. Knyazev
S. M. Knyazev
NZN. A. Zakharova
N. A. Zakharova
Breast cancer is the most common cancer in women and one of the leading causes of death from cancer in Russia and most countries of the world. In countries with mammographic screening, there is a decrease in mortality from breast cancer. Introduction of mammographic image evaluation platforms into radiologist practice based on the work of artificial intelligence it allows not only to increase the coverage of the female population, but also to reduce the cost of screening, but it also increases the sensitivity and specificity of mammography as a method of breast cancer screening.The article presents the results of a study on the evaluation of mammographic images in women who have passed a preventive study using an artificial intelligence program.Within the framework of this project, mammographic images were analyzed using the service for viewing medical images “Celsus” in 8030 patients. The study assessed the age groups of 40-49 years, 50-59 years, 60 years and older. The average age of patients with suspected breast cancer was 54.8 years. Breast cancer was detected in 13 women (1.2 %), while the highest percentage of breast cancer was detected in the group with mammographic density D.

16 July 2019 in Medical Visualization
Verified
Journal Article
Closed access
ACA. V. Chernaya
A. V. Chernaya
SNS. N. Novikov
S. N. Novikov
PKP. V. Krivorotko
P. V. Krivorotko
RUR. Kh. Ulyanova
R. Kh. Ulyanova
VDV. V. Danilov
V. V. Danilov
Purpose: to study the possibilities of contrast enhanced dual-energy spectral mammography (CESM) in the diagnostics of malignant tumors in the breast. Material and methods. Forty-seven patients with suspicious for breast cancer (BC) lesions underwent CESM. Digital mammography (MMG) and post-contrast images were correlated with the results of path morphological studies after surgery or puncture biopsy was performed. Results . Sensitivity, specificity and overall accuracy in the diagnostics of breast cancer were 83.3%, 85.7%, 85.1% for digital mammography and 91.6%, 91.4%, 91.4% for CESM, respectively. The positive predictive value was 66.6% for digital MMG and 78.5% for CESM. The negative predictive value (NPV) was 96.9% for the CESM and exceeded NPV of the digital MMG, which was 93.7%. Conclusion. Thus, these findings suggest that CESM is an effective method for the diagnostics of malignant tumors in the breast.

30 September 2020 in Journal of oncology: diagnostic radiology and radiotherapy
Verified
Journal Article
Open access
PDF file
ACA. V. Chernaya
A. V. Chernaya
ARA. V. Reva
A. V. Reva
RUR. Kh. Ulianova
R. Kh. Ulianova
LSL. N. Shevkunov
L. N. Shevkunov
ПКП. В. Криворотько
П. В. Криворотько
РУР. Х. Ульянова
Р. Х. Ульянова
Mastitis is an inflammatory condition of the breast, which may or may not be accompanied by infection (WHO 2000).Idiopathic granulomatous mastitis is one of the forms of non-infectious mastitis. Granulomatous lobular mastitis is a rare inflammatory disease of the breast that was first described by Kessler and Wolloch in 1972.Idiopathic granulomatous mastitis (IGM) or granulomatous lobular mastitis is chronic inflammatory breast disease of unknown etiology, the clinical manifestation and radiological features of which may mimic other nosological entities.We report a case of 29 year old woman who was diagnosed with breast carcinoma by radiological methods, such as contrast enhanced spectral mammography (CESM), magnetic resonance imaging with dynamic contrast enhancement (MRI with DCE), SPECT/CT. However, performed core needle biopsy of a lesion shows no tumor cells. The conservative treatment was suggested, based on obtained information.Aim is a review of radiological features of IGM with contrast enhanced visualization methods, based on our clinical case; description of differential radiological features in comparison with similar diseases of the breast, such as inflammatory breast carcinoma, tuberculosis etc.

28 December 2022 in Medical Visualization
Verified
Journal Article
Open access
PDF file
ACA. V. Chernaya
A. V. Chernaya
RUR. Kh. Ulyanova
R. Kh. Ulyanova
SBS. S. Bagnenko
S. S. Bagnenko
ПКП. В. Криворотько
П. В. Криворотько
AAA. S. Artemyeva
A. S. Artemyeva
РУР. Х. Ульянова
Р. Х. Ульянова
Introduction. Differential diagnosis of some pathological processes in the breast is difficult on the background of dense breast tissue. This often leads to false conclusions and to late diagnosis of breast cancer (BC) or unreasonable biopsy in a benign process. 50% of breast cancers detected less than 12 months after elective mammography were associated with high density of breast tissue. An important advantage of contrast enhanced spectral mammography (CESM) is that it does not depend on the size of the lesions and the X-ray density of the breast tissue. Objective. To compare the diagnostic performance of CESM and digital mammography (DM) in detection of breast cancer in a group of women with dense breast tissue. Materials and methods. The data of 438 patients with suspected breast cancer examined from August 2018 to January 2021 were analyzed in the study. The mean age of women was 50 ± 11 years (from 21 to 86 years). In the study group 154 (35%) malignant and 284 (65%) benign lesions were identified. All lesions were histologically verified. Breast tissue density corresponded to types A and B in 161 patients and corresponded to C and D types in 277 patients according to the ACR classification. 154 cases of breast cancer were identified, including 49 patients with density A and B and 105 patients with density C and D types. Results. Sensitivity, specificity and overall accuracy of DM were 85.7%, 87.3%, 86.8%, respectively. Diagnostic performance of CESM significantly higher than of DM with sensitivity, specificity and accuracy of 96.8% (p < 0.001), 93.3% (p = 0.015), 94.5% (p < 0.001), respectively. CESM had high positive and negative predictive values of 88.7% (p = 0.012) and 98.1% (p < 0.001), which exceeded those of DM – 78.6% and 91.9%, respectively. The diagnostic performance of DM and CESM were comparable in women with normal breast density (types A and B according to ACR), but in patients with high breast density (types C and D according to ACR), CESM was significantly more sensitive in detecting breast cancer. Conclusion. Thus, diagnostic efficiency of CESM in detecting breast cancer significantly higher in comparison with digital mammography.

20 December 2021 in Tumors of female reproductive system
Verified
Journal Article
Open access
PDF file
ACA. V. Chyornaya
A. V. Chyornaya
RUR. Kh. Ulyanova
R. Kh. Ulyanova
ПКП. В. Криворотько
П. В. Криворотько
AAA. S. Artemyeva
A. S. Artemyeva
SBS. S. Bagnenko
S. S. Bagnenko
РУР. Х. Ульянова
Р. Х. Ульянова
Background. Breast cancer (BC) can be unifocal, multifocal, multicentric (MCBC) and bilateral according to number and localization of tumors. MCBC has different clinical and biological characteristics compared to unifocal BC, for example, a higher risk of lymph node involvement, a more aggressive natural history and a worse prognosis. Therefore, accurate diagnosis and detection of MCBC is one of the main tasks of imaging.Objective: to compare diagnostic accuracy of contrast enhanced spectral mammography (CESM) and digital mammography (DM) in the diagnosis of MCBC.Materials and methods. The study included 438 women with suspected BC. The results of DM and CESM were compared with the results of a pathomorphological study performed after surgery or biopsy to assess the effectiveness of imaging modalities. DM was performed for all women using a Senographe DS (GE, USA) unit. CESM was performed after intravenous injection of non-ionic contrast agents using injector with breast compression in the craniocaudal and mediolateral projections. The study was performed for both glands regardless of the location of the suspicious lesion in order to timely diagnose clinically asymptomatic bilateral cancer. The final diagnosis was made based on the results of the pathomorphological examination. MCBC was diagnosed when two or more tumors at a distance of 3 cm or more from each other were detected. Visualization of additional grouped calcifications of malignant type occupying a small portion of breast tissue (more than 15 pieces per 1 sq. cm) was considered as another mammographic sign of MCBC.Results. According to the pathomorphological examination BC was diagnosed in 154 (35 %) women out of 438 examined patients. MCBC was identified in 25 (16 %) of 154 patients. CESM was more effective than DM in detecting MCBC with sensitivity of 88.0 % vs 48.0 % (p = 0.002), accuracy of 92.2 % vs 90.9 %, negative predictive value of 97.6 % vs 90.8 % (p = 0.02), respectively. But the specificity was significantly higher in DM than in CESM – 99.2 % vs 93.0 % (p = 0.009), respectively, and the positive predictive value did not differ significantly (p = 0.12).Conclusion. CESM is a more sensitive method for diagnosing MCBC compared to DM with sensitivity of 88.0 % vs 48.0 %. The high negative predictive value of CESM (97.6 %) confirms the fact that this modality is an effective method for planning surgery and radiation therapy.