2 December 2020 in Critical Reviews in Clinical Laboratory Sciences
In the clinical laboratory, knowledge of and the correct use of clot activators and anticoagulant additives are critical to preserve and maintain samples in optimal conditions prior to analysis. In 2017, the Latin America Confederation of Clinical Biochemistry (COLABIOCLI) commissioned the Latin American Working Group for Preanalytical Phase (WG-PRE-LATAM) to study preanalytical variability and establish guidelines for preanalytical procedures to be applied by clinical laboratories and health care professionals. The aim of this critical review, on behalf of COLABIOCLI WG-PRE-LATAM, is to provide information to understand the mechanisms of the interactions and reactions that occur between blood and clot activators and anticoagulant additives inside evacuated tubes used for laboratory testing. Clot activators – glass, silica, kaolin, bentonite, and diatomaceous earth – work by surface dependent mechanism whereas extrinsic biomolecules – thrombin, snake venoms, ellagic acid, and thromboplastin - start in vitro coagulation when added to blood. Few manufacturers of evacuated tubes state the type and concentration of clot activators used in their products. With respect to anticoagulant additives, sodium citrate and oxalate complex free calcium and ethylenediaminetetraacetic acid chelates calcium. Heparin potentiates antithrombin and hirudin binds to active thrombin, inactivating the thrombin irreversibly. Blood collection tubes have improved continually over the years, from the glass tubes containing clot activators or anticoagulant additives that were prepared by laboratory personnel to the current standardized evacuated systems that permit more precise blood/additive ratios. Each clot activator and anticoagulant additive demonstrates specific functionality, and both manufacturers of tubes and laboratory professional strive to provide suitable interference-free sample matrices for laboratory testing. Both manufacturers of in vitro diagnostic devices and laboratory professionals need to understand all aspects of venous blood sampling so that they do not underestimate the impact of tube additives on laboratory testing.
15 June 2018 in Biochemia Medica
The aim of this work is to design a selection algorithm for total allowable error (TEa) source using a graphic tool that, by integrating internal (IQC) and external (EQC) quality control performances, enables the laboratory to evaluate which TEa source better fits the test analytical performance. Two analytical performance indicators (bias and Sigma metrics) were estimated for 23 biochemistry tests during 2016. Bias was estimated on the EQC, and Sigma metrics was calculated through the results obtained in the IQC. The Sigma metrics was charted as a function of the bias (TEa%). Following the proposed algorithm (considering the hierarchy in the Milan 2014 consensus), the TEa was evaluated depending on two areas. One area in the chart was defined as the objective area in which the used TEa is the appropriate one for the analytical performance of the test under evaluation. For any test located outside this area, a performance re-evaluation was required using another source of TEa. In 19 out of 23 evaluated tests, the resulting analytical performance allowed for the selection of biologic variability as TEa source. In the four remaining cases, TEa sources of lesser hierarchy were selected. The graphic tool designed together with the proposed algorithm enabled the laboratory to standardize the selection procedure of the most appropriate TEa for the test analytical performance.