Junlei Wang

Junlei Wang

Auto-generated profile, based on publicly available information

Junlei Wang

PetroChina Research Institute of Petroleum Exploration & Development, Beijing 100083, China

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 April 2020 in Advances in Geo-Energy Research
Verified
Journal Article
Open access
PDF file
MMMeiling Meng
Meiling Meng
ZCZhiming Chen
Zhiming Chen
XLXinwei Liao
Xinwei Liao
JWJunlei Wang
Junlei Wang
LSLumin Shi
Lumin Shi
A well-testing method for parameter evaluation of multiple fractured horizontal wells with non-uniform fractures in shale oil reservoirs

23 March 2016 in Transport in Porous Media
Verified
Journal Article
Closed access
PDF file
JWJunlei Wang
Junlei Wang
YWYunsheng Wei
Yunsheng Wei
YQYadong Qi
Yadong Qi

30 April 2020 in Water Resources Research
Verified
Journal Article
Open access
PDF file
WLWanjing Luo
Wanjing Luo
JWJunlei Wang
Junlei Wang
LWLei Wang
Lei Wang
Yingfang ZhouYingfang Zhou
Yingfang Zhou
This study developed an alternative boundary element method (BEM) to simulate the transient flow behavior of groundwater induced by well extraction in a confined fractured aquifer containing a network of discrete or connected fractures. The matrix flow, network‐fracture flow, and matrix‐fracture fluid exchange were considered. The aquifer was treated as a heterogeneous whole that consisted of fracture and matrix blocks with locally homogeneous hydraulic properties. The fractures were explicitly represented to be of true finite volume rather than nonrepresentational line sources. A semianalytical solution was developed based on the theory of a BEM in the Laplace transform domain, but the analytical Green's function was used for the bounded domain rather than the free‐space Green's function in a conventional BEM. Case studies were presented in order to investigate the flow exchange behavior between the matrix and fractures and the corresponding transient drawdown response. The results showed that (1) exchange flux distribution calculated with the classical infinitesimal fracture model was consistent with the difference of the normal drawdown derivative values on both sides of the fracture body in our model. (2) When the well was in the matrix, the fractures acted as both highly conductive conduits and leaky faults, and the drawdown derivative behaviors resembled the characteristics of a dual‐porosity reservoir model. (3) When the well was in the network fracture and when the volume of fracture was of the same order of magnitude as the matrix, the drawdown derivative might exhibit the look‐alike behavior of a dual‐porosity model.

1 August 2020 in Journal of Natural Gas Science and Engineering
Verified
Journal Article
Closed access
YWYunsheng Wei
Yunsheng Wei
AJAilin Jia
Ailin Jia
JWJunlei Wang
Junlei Wang
CLChao Luo
Chao Luo
YQYadong Qi
Yadong Qi

15 November 2014 in Journal of Central South University
Verified
Journal Article
Closed access
PDF file
JWJun-Lei Wang
Jun-Lei Wang
CYCun-Zhang Yan
Cun-Zhang Yan
AJAi-Lin Jia
Ai-Lin Jia
DHDong-Bo He
Dong-Bo He
YWYun-Sheng Wei
Yun-Sheng Wei
YQYa-Dong Qi
Ya-Dong Qi

15 December 2025 in Energies
Verified
Journal Article
Open access
PDF file
TSTao Song
Tao Song
HWHongjun Wu
Hongjun Wu
PLPingde Liu
Pingde Liu
JWJunyi Wu
Junyi Wu
CWChunlei Wang
Chunlei Wang
FWFalin Wei
Falin Wei
Gel treatments have been widely applied to control water production in oil and gas reservoirs. However, for water shutoff in dense gas reservoirs, most gel-based treatments focus on individual wells rather than the entire reservoir, exhibiting limited treatment depth, poor durability, and inadequate repeatability Notably, formation damage is a primary consideration in treatment design—most dense gas reservoirs have a permeability of less than 1 mD, making them highly susceptible to damage by formation water, let alone viscous polymer gels. Constrained by well completion methods, gelant can only be bullheaded into deep gas wells in most scenarios. Due to the poor gas/water selective plugging capability of conventional gels, the injected gelant tends to enter both gas and water zones, simultaneously plugging fluid flow in both. Although several techniques have been developed to re-establish gas flow paths post-treatment, treating gas-producing zones remains risky when no effective barrier exists between water and gas strata. Additionally, most water/gas selective plugging materials lack sufficient thermal stability under high-temperature and high-salinity (HTHS) gas reservoir conditions, and their injectivity and field feasibility still require further optimization. To address these challenges, treatment design should be optimized using non-selective gel materials, shifting the focus from directly preventing formation water invasion into individual wells to mitigating or slowing water invasion across the entire gas reservoir. This approach can be achieved by placing large-volume gels along major water flow paths via fully watered-out wells located at structurally lower positions. Furthermore, the drainage capacity of these wells can be preserved by displacing the gel slug to the far-wellbore region, thereby dissipating water-driven energy. This study evaluates the viability of placing gels in fully watered-out wells at structurally lower positions in an edge-water drive gas reservoir to slow water invasion into structurally higher production wells interconnected via numerous microfractures and high-permeability streaks. The gel system primarily comprises polyethyleneimine (PEI), a terpolymer, and nanofibers. Key properties of the gel system are as follows: Static gelation time: 6 h; Elastic modulus of fully crosslinked gel: 8.6 Pa; Thermal stability: Stable in formation water at 130 °C for over 3 months; Injectivity: Easily placed in a 219 mD rock matrix with an injection pressure gradient of 0.8 MPa/m at an injection rate of 1 mL/min; and Plugging performance: Excellent sealing effect on microfractures, with a water breakthrough pressure gradient of 2.25 MPa/m in 0.1 mm fractures. During field implementation, cyclic gelant injections combined with over-displacement techniques were employed to push the gel slug deep into the reservoir while maintaining well drainage capacity. The total volumes of injected fluid and gelant were 2865 m3 and 1400 m3, respectively. Production data and tracer test results from adjacent wells confirmed that the water invasion rate was successfully reduced from 59 m/d to 35 m/d. The pilot test results validate that placing gels in fully watered-out wells at structurally lower positions is a viable strategy to protect the production of gas wells at structurally higher positions.