Tobias Werther

Tobias Werther

Auto-generated profile, based on publicly available information

Tobias Werther

Division of Neonatology, Pediatric Intensive Care, and Neuropediatrics, Department of Pediatrics and Adolescent Medicine, Medical University of Vienna, Vienna, Austria

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2019 in JAMA Pediatrics
Verified
Journal Article
Closed access
PDF file
VGVito Giordano
Vito Giordano
JEJoy Edobor
Joy Edobor
PDPhilipp Deindl
Philipp Deindl
BWBrigitte Wildner
Brigitte Wildner
KGKatharina Goeral
Katharina Goeral
MOMonika Olischar
Monika Olischar
Importance Because children in a preverbal stage of development are unable to voice their feelings, they completely depend on their caregiving team for the interpretation and management of their pain and discomfort. Thus, accurately validated scales to assess pain and sedation levels are crucial. Objective To provide clinicians a complete overview on the validity and reliability of the existing pain and sedation scales for different target populations (preterm infants, term infants, and toddlers) and in different clinical contexts. Evidence Review BIOSIS Previews, Cumulative Index to Nursing and Allied Health Literature, Cochrane Central Register of Controlled Trials, Cochrane Database of Systematic Reviews, Embase, MEDLINE, PsycCRITIQUES, PsycINFO, PSYNDEXplus Literature and Audiovisual Media, and PSYNDEXplus Tests were the databases screened from their inception to August 2018. All studies examining the validity or reliability of a given pain or sedation scale for patients in a preverbal stage of development were included in this systematic review. Those scales that were tested for at least construct validity, internal consistency, and interrater reliability were subsequently scored using the consensus-based standards for the selection of health measurement instruments (COSMIN) checklist. Findings In total, 89 validation articles comprising 65 scales were included. Fifty-seven scales (88%) were useful for assessing pain, 13 scales (20%) for assessing sedation, and 4 scales (6%) for assessing both conditions. Forty-two (65%) were behavioral scales, and 23 (35%) were multidimensional scales. Eleven scales (17%) were validated for infants on mechanical ventilation. Thirty-seven scales (57%) were validated for preterm infants, 24 scales (37%) for term and preterm infants, 7 scales (11%) for term-born children, 7 scales (11%) for preterm infants, term infants, and toddlers, and 17 scales (26%) for term infants and toddlers. Twenty-eight scales (43%) considered construct validity, internal consistency, and interrater reliability. Conclusions and Relevance Clinicians should consider using scales that are validated for at least construct validity, internal consistency, and interrater reliability, combining this information with the population of interest and the construct the scale is intended to measure.

30 May 2022 in Neonatology
Verified
Journal Article
Open access
PDF file
MSMirjam Steiner
Mirjam Steiner
BUBerndt Urlesberger
Berndt Urlesberger
VGVito Giordano
Vito Giordano
GKGregor Kasprian
Gregor Kasprian
SGSarah Glatter
Sarah Glatter
KGKatharina Goeral
Katharina Goeral
Objective: The aim of the study was to determine the predictive power of the combined use of neurophysiological (amplitude-integrated electroencephalography [aEEG], near-infrared spectroscopy [NIRS]) methods and neuroimaging (magnetic resonance imaging [MRI]) for long-term outcome prediction in neonates with hypoxic-ischaemic encephalopathy (HIE). Study Design: Prospective cohort study of 56 patients with moderate to severe HIE and hypothermia treatment at the Medical University of Vienna between 2008 and 2020. aEEG and NIRS were recorded continuously over a period of >4 days (102 h) starting at the initiation of hypothermia treatment, MRI was performed at a median age of 8 days. Receiver operating characteristic curves and area under the curve were calculated to evaluate the prognostic ability of aEEG, NIRS, and MRI parameters for outcome assessed via Bayley Scales of Infant Development 3rd edition at 2 years of age. Results: Combined aEEG and MRI parameters showed highest predictive power regarding long-term outcome. The highest area under the curve values (0.96–0.99) were obtained for aEEG (combination of background pattern and sleep-wake cycling) between 66 and 102 h after initiation of hypothermia in combination with MRI findings. NIRS parameters did not differ significantly between infants with favourable and adverse outcome. Conclusions: Combined aEEG and MRI parameter scores were more predictive than single parameter scores. No further improvement was observed when combining aEEG/MRI with NIRS data.

24 July 2021 in Children
Verified
Journal Article
Open access
PDF file
LALukas Aichhorn
Lukas Aichhorn
EKErik Küng
Erik Küng
LHLisa Habrina
Lisa Habrina
TWTobias Werther
Tobias Werther
ABAngelika Berger
Angelika Berger
Bernhard SchwabergerBernhard Schwaberger
Bernhard Schwaberger
Lung ultrasound makes use of artifacts generated by the ratio of air and fluid in the lung. Recently, an enormous increase of research regarding lung ultrasound emerged, especially in intensive care units. The use of lung ultrasound on the neonatal intensive care unit enables the clinician to gain knowledge about the respiratory condition of the patients, make quick decisions, and reduces exposure to ionizing radiation. In this narrative review, the possibilities of lung ultrasound for the stabilization and resuscitation of the neonate using the ABCDE algorithm will be discussed.

1 November 2018 in Pediatric Critical Care Medicine
Verified
Journal Article
Closed access
Michael WagnerMichael Wagner
Michael Wagner
KHKirstin Hauser
Kirstin Hauser
FCFrancesco Cardona
Francesco Cardona
GSGeorg M. Schmölzer
Georg M. Schmölzer
ABAngelika Berger
Angelika Berger
TWTobias Werther
Tobias Werther
Objectives: Critically ill neonatal and pediatric patients often require central vascular access. Real-time ultrasound guidance for central venous catheterization is beneficial. Because the diameter of central veins is much smaller in neonates than in adults, extensive training is needed to master the visualization and catheterization of central veins in neonates. This study assessed the learning effect of a standardized simulation-based teaching program on ultrasound-guided cannulation in a low-cost cadaver tissue model. Design: This simulation-based prospective study assessed physician competence in the ultrasound-guided central venous catheterization procedure. Analyses were conducted before and after the teaching course. Setting: Pediatric simulation center at a tertiary care center. Subjects: Staff physicians from the Neonatal ICU and PICUs at the Medical University of Vienna. Interventions: Two latex tubes, with internal diameters of 2 and 4mm, were inserted in parallel into cadaver tissue to mimic vessels and create a model for central venous catheterization. Measurements and Main Results: Under ultrasound guidance, each participant attempted to puncture and insert a guide-wire into each of the latex tubes using in-plane and out-of-plane techniques, both before and after the teaching course. The training program was assessed using a questionnaire and a performance checklist. Thirty-nine physicians participated in this study. The rates of failure of guide-wire insertion into 2-mm tubes were significantly lower after than before the teaching course, using both in-plane (p = 0.001) and out-of-plane (p = 0.004) techniques. Teaching, however, did not significantly reduce the insertion failure rate into 4-mm tubes, either in-plane (p = 0.148) or out-of-plane (p = 0.069). The numbers of successful cannulations on the first attempt increased after the teaching in all methods (p = 0.001). Conclusions: Implementation of a skills training program for ultrasound-guided central venous catheterization in a cadaver tissue model was feasible and cost- and time-effective. The number of attempts until successful cannulation of small vessels (2-mm tube) was significantly lower after than before the standardized teaching program.

3 August 2021 in Archives of Disease in Childhood - Fetal and Neonatal Edition
Verified
Journal Article
Closed access
PDF file
TWTobias Werther
Tobias Werther
LALukas Aichhorn
Lukas Aichhorn
SSSina Stellberg
Sina Stellberg
FCFrancesco Stefano Cardona
Francesco Stefano Cardona
KKKatrin Klebermass-Schrehof
Katrin Klebermass-Schrehof
Michael WagnerMichael Wagner
Michael Wagner
Objective: To assess the reliability, accuracy and precision of distal end-tidal capnography (detCO2) in neonates compared with transcutaneous (tcCO2) carbon dioxide measurements. Design: Observational, prospective clinical study. Setting: Neonatal intensive care unit at Medical University of Vienna. Participants: Conventionally ventilated neonates with a body weight between 1000 g and 3000 g. Intervention: End-tidal partial pressure of CO2 was measured in distal position using the separate lumen of a double-lumen endotracheal tube connected to an external side-stream capnometer. Three consecutive detCO2 and tcCO2 values were recorded simultaneously and compared with simultaneous arterialised partial pressure of CO2 (paCO2) measurements in each patient. Main outcome measures: Reliability, accuracy and precision of detCO2 and tcCO2 measurements compared with paCO2 in neonates. Results: Twenty-five neonates were included with a median (range) weight at enrolment of 1410 (1010–2980) g, from which 81 simultaneous measurements of detCO2, tcCO2 and paCO2 were obtained. The mean (SD) of paCO2, detCO2 and tcCO2 was 45.0 (8.6) mmHg, 42.4 (8.4) mmHg and 50.4 (20.4) mmHg, respectively. The intraclass correlation between paCO2 and detCO2 and between paCO2 and tcCO2 reached 0.80 (95% CI 0.71 to 0.87, p<0.001) and 0.59 (95% CI 0.43 to 0.72, p<0.001), respectively. In the Bland-Altman analysis, bias and precision of detCO2 with respect to paCO2 amounted to −2.68 mmHg and 10.62 mmHg (95% CI 8.49 to 14.51), respectively. Bias and precision of tcCO2 with respect to paCO2 amounted to 5.39 mmHg and 17.22 mmHg (95% CI 13.21 to 23.34), respectively. Conclusion: DetCO2 had better reliability, accuracy and precision with paCO2 than tcCO2 in ventilated neonates without severe lung diseas. Trial registration number: NCT03758313.

26 July 2024 in European Respiratory Journal
Verified
Journal Article
Closed access
PDF file
EZEmanuela Zannin
Emanuela Zannin
CRCamilla Rigotti
Camilla Rigotti
SSSven M. Schulzke
Sven M. Schulzke
RSRichard Sindelar
Richard Sindelar
TWTobias Werther
Tobias Werther
CVChiara Veneroni
Chiara Veneroni
Background: This multicentre, international, retrospective study aimed to investigate whether respiratory system reactance (Xrs) assessed by respiratory oscillometry on day 7 of life is associated with respiratory outcomes in preterm infants below 32 weeks gestational age (GA).Methods: Sinusoidal pressure oscillations (2–5 cmH2O peak-to-peak, 10 Hz) were superimposed on the positive end-expiratory pressure. We assessed the association ofXrsz-score with the duration of respiratory support using linear regression and with bronchopulmonary dysplasia (BPD) using logistic regression. We used the likelihood ratio test to evaluate whetherXrsz-score adds significantly to clinical predictors, including GA, birthweight (BW) and the National Institute of Child Health and Human Development (NICHD) BPD prediction model.Results: 137 infants (median (interquartile range) 28.43 (26.11–30.29) weeks GA) were included; 44 (32%) developed BPD.Xrsz-score was significantly associated with the duration of respiratory support (R2=0.35).Xrsz-score was significantly higher in infants who developed BPD (p<0.001); the optimal cut-off value was 2.6, associated with 77% sensitivity and 80% specificity. In univariable analysis, per z-score increase inXrs, the odds ratio for BPD increased by 60% and the respiratory support by 8 days. In multivariable analysis,Xrsz-score added significantly to the NICHD model and to GA and BW z-score to predict respiratory support duration (p=0.016 and p=0.014, respectively) and BPD development (p=0.003 and p<0.001, respectively).Conclusion: Xrsz-score on the 7th day after birth improves the prediction of respiratory outcome in preterm infants.