3 December 2008 in Metallurgical and Materials Transactions A
15 June 2018 in Zastita materijala
In this paper analyzed was the influence of implementation of inert Ar gas and a mixture of inert plasma Ar / He gases in a vacuum chamber on the deposition of reactive niobium (Nb) powder. The aim of this paper was to deposit coating layers of high density, without oxide content, that will find application in the field of biomedicine. Detailed examination was performed of mechanical properties of microhardness using the HV0.3 method, of tensile bond strength by tensile testing and of the microstructure of the coating layers in the deposited state and after etching. For etching a solution of nitric acid HNO3 and hydrofluoric acid HF in a ratio of 1:1was used. It was found that inert gases, at low pressure prevent the reaction of gases with the metal droplets of molten Nb powder particles during the plasma spray deposition process. The density of the deposited coating in vacuum chamber is higher than that of coatings which are deposited at atmospheric pressure with reactive plasma gases N2 and H2. This is attributed to the elimination of thin oxide and nitride films at the interlamellar Nb contact, substantially increasing the ductility of the coating, eliminating the micro cracks through the deposited layers, which was confirmed by metallographic examination of samples. Tests have shown that VPS - Nb coating layers have mechanical properties and microstructure which completely enable the use of the coating on implants.
1 January 2019 in Thermal Science
The aim of this study was to investigate the thermal cycling behaviour of NiCr-Al-Co- Y O bond coating in thermal barrier coating system with ZrO -MgO as a top coating. 2 3 2 The coatings were deposited by atmospheric plasma spraying on stainless steel X15Cr13 (EN 1.4024) substrate. The used composite powder NiCr-Al-Co-Y O was mechanically 2 3 cladded, and the steel substrates were preheated to 160-180 ?C. The thermal cycling performance of the obtained bond coat and the effect of formed complex ceramic oxides of the Al O -Y O system were tested by heating to 1200 ?C and cooling in air to 2 3 2 3 160-180 ?C. The number of performed thermal cycles was 7, 32, and 79. The quality of the obtained coating, as well as its thermal cycling behaviour, was assessed through the microstructural analysis, microhardness and tensile bond strength measurements, and change in chemical composition and microhardness. The obtained results showed that the steel substrate, bond coat oxidation and interdiffusion at bond coat/substrate interface have a significant influence on changes in chemical composition and microhardness of the bond coat. The correlation between oxidation behaviour of NiCr- Al-Co-Y O bond coat and number of thermal cycles was also discussed.
15 December 2018 in Zastita materijala
Tantalum is a very popular material for the industry as a whole because of very important characteristics such as: high melting point, significant thermal and electrical conductivity, high toughness and resistance to corrosion and good biocompatibility. Since the tantalum metal is sensitive to O, N and H gases, tantalum coating layers are deposited only using the vacuum plasma spray process (VPS), which has, in the past few years been used successfully for preparing coatings which are widely used in the preparation of metal implants. The aim of this paper was to, at a low pressure inert gas eliminate the influence of the surrounding atmosphere on the melted Ta powder particles and produce coatings with mechanical and structural characteristics which will find application in biomedicine. For depositing the coating a commercial tantalum powder AMPERIT® 151065 grain size of 10 - 30 μm was used. The powder was deposited with a plasma F4 gun at a distance of substrates at 300 mm. The Ta coating layers were deposited with a thickness of 60 to 70 μm on steel substrates. As the plasma gas used was a mixture of Ar and He inert gases. The microhardness of the coating was tested using the HV0.3 method and the tensile strength of the coatings bond was tested by the tensile method in accordance with the ASTM C633-1 standard. The microstructure of the coating in deposited state and after etching was studied on an optical microscope (OM) and scanning electron microscope (SEM). Etching the coating was carried out in the reagent which consisted of two parts of nitric acid, two parts hydrofluoric acid, and five parts water (2HNO3: 2HF: 5H2O). The structure of the coating consists solely of a tough αTa phase with a body centered cubic lattice. Tests have shown that layers of VPS - Ta coatings have the microstructure and mechanical properties which completely support the use of the coating in the process of making implants.
1 January 2012 in Vojnotehnicki glasnik
This paper analyzes the influence of plasma spray parameters on the microstructure and mechanical properties of NiCrBSi coatings deposited by the atmospheric plasma spray (APS) process. The microstructure and mechanical properties of plasma spray coatings are determined by the interaction of plasma ions with powder particles when the rate and temperature of plasma particles are transferred to powder particles. The interaction effect directly depends on the time the powder particles spend in plasma, and that time is defined by the deposition distance for each type of powder, depending on the grain size, melting temperature and specific mass. In order to obtain homogeneous and dense coatings, three distances (70,120 and 170 mm) from the substrate were used in the research. The coating of the best structural and mechanical characteristics was remelted and fused to the base in order to obtain a better structure. Self - fluxing NiCrBSi alloys are widely used because of the good resistance of boride, carbide and silicide solid phases to wear and corrosion. The morphology of powder particles was examined in the SEM (Scanning Electron Microscope), while the microstructure of the layers was assessed using a light microscope. The microstructural analysis of the deposited layers was performed in accordance with the Pratt-Whitney standard. The mechanical properties of the layers were assessed by applying the HV0.3 method for microhardness testing and tensile testing was applied to test bond strength.