Julio C. Parra

Julio C. Parra

Auto-generated profile, based on publicly available information

Julio C. Parra

Universitat Politcnica de Catalunya, Barcelona, Spain

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2025 in IEEE Transactions on Electromagnetic Compatibility
Verified
Journal Article
Closed access
JPJulio C. Parra
Julio C. Parra
LKLirim Koraqi
Lirim Koraqi
DPDavy Pissoort
Davy Pissoort
MFMireya Fernández-Chimeno
Mireya Fernández-Chimeno
FLFrank Leferink
Frank Leferink
MAMarco A. Azpúrua
Marco A. Azpúrua
This study uses time domain measurements to determine the magnetic field shielding effectiveness (SE) of materials at frequencies below 30 MHz. The setup, inspired by the IEEE 299, employs a shielded room and two loop antennas. To address the challenge of dynamic range compression, commonly encountered when measuring broadband signals, three waveform types —a single pulse, a multitone, and a chirp— are evaluated with respect to the signal-to-noise ratio and detection sensitivity. Validations are performed through comparisons with the existing frequency domain methods and numerical simulations. Using multitone excitation with optimized amplitudes allowed measuring magnetic field SE up to 65 dB. The findings indicate our proposal is a viable alternative for characterizing magnetic field SE in this frequency range, offering comparable results to the vector network analyzer-based method, with the added benefit of faster measurements.

12 May 2025
Verified
Conference Paper
Closed access
JPJulio C. Parra
Julio C. Parra
LKLirim Koraqi
Lirim Koraqi
DPDavy Pissoort
Davy Pissoort
MFMireya Fernandez-Chimeno
Mireya Fernandez-Chimeno
FLFrank Leferink
Frank Leferink
MAMarco A. Azpúrua
Marco A. Azpúrua
This study uses time domain measurements to determine the magnetic field shielding effectiveness of materials within the frequency range of 200 kHz to 30 MHz. The setup, based on the IEEE 299, employs a shielded room and two loop antennas. A multitone waveform is used as the excitation signal to address dynamic range compression, a common challenge in broadband measurements. Validation through comparisons with frequency domain techniques shows that the time domain approach can reliably assess magnetic field SE up to 65 dB. The results suggest that this method is a viable alternative to vector network analyzer-based methods, offering comparable results with significantly reduced measurement time, making it well-suited for characterizing shielding materials in a variety of applications, including space.