This study uses time domain measurements to determine the magnetic field shielding effectiveness (SE) of materials at frequencies below 30 MHz. The setup, inspired by the IEEE 299, employs a shielded room and two loop antennas. To address the challenge of dynamic range compression, commonly encountered when measuring broadband signals, three waveform types —a single pulse, a multitone, and a chirp— are evaluated with respect to the signal-to-noise ratio and detection sensitivity. Validations are performed through comparisons with the existing frequency domain methods and numerical simulations. Using multitone excitation with optimized amplitudes allowed measuring magnetic field SE up to 65 dB. The findings indicate our proposal is a viable alternative for characterizing magnetic field SE in this frequency range, offering comparable results to the vector network analyzer-based method, with the added benefit of faster measurements.
This study uses time domain measurements to determine the magnetic field shielding effectiveness of materials within the frequency range of 200 kHz to 30 MHz. The setup, based on the IEEE 299, employs a shielded room and two loop antennas. A multitone waveform is used as the excitation signal to address dynamic range compression, a common challenge in broadband measurements. Validation through comparisons with frequency domain techniques shows that the time domain approach can reliably assess magnetic field SE up to 65 dB. The results suggest that this method is a viable alternative to vector network analyzer-based methods, offering comparable results with significantly reduced measurement time, making it well-suited for characterizing shielding materials in a variety of applications, including space.