Joar Sivertsen

Joar Sivertsen

Auto-generated profile, based on publicly available information

Joar Sivertsen

Department of Immunology and Transfusion Medicine Haukeland University Hospital Bergen Norway

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 March 2020 in Transfusion
Verified
Journal Article
Open access
PDF file
JSJoar Sivertsen
Joar Sivertsen
HBHanne Braathen
Hanne Braathen
TLTurid Helen Felli Lunde
Turid Helen Felli Lunde
EKEinar K. Kristoffersen
Einar K. Kristoffersen
THTor Hervig
Tor Hervig
TATorunn O. Apelseth
Torunn O. Apelseth
BACKGROUND: Some jurisdictions require leukoreduction of cellular blood components. The only whole blood collection set with a platelet‐saving filter uses citrate‐phosphate‐dextrose (CPD) as storage solution. Substituting CPD with citrate‐phosphate‐dextrose‐adenine (CPDA‐1) increases shelf life from 21 to 35 days. This would simplify prehospital and rural resupply and reduce wastage. We investigated in vitro quality and hemostatic properties of CPDA‐1 whole blood leukoreduced with a platelet‐saving filter.STUDY DESIGN AND METHODS: CPDA‐1 whole blood was leukoreduced using a platelet‐saving filter and stored 35 days. EDQM requirements, hematology, metabolic parameters, thromboelastography, light transmission aggregometry, fibrinogen, factor VIII, and interleukin‐6 were measured on Days 0, 1, 14, 21, and 35 and compared to non‐leukoreduced blood.RESULTS: All units met EDQM requirements. Leukoreduction yielded residual white blood cell count 0.8% was observed. Factor VIII was higher on Day 35 in the leukoreduced group, 37.9 (95% CI: 26.0, 49.8) versus 13.8 (9.4, 18.2) IU/dL. In both groups, aggregation was significantly reduced by Day 14. Thromboelastography showed remaining platelet activity on Day 35, MA 46.9 (42.1, 51.7) in the leukoreduced and 44.3 (39.6, 49.0) mm in the non‐leukoreduced group. Fibrinogen was within reference ranges at Day 35 (>2 g/dL). Interleukin‐6 was not detectable.CONCLUSION: Leukoreducing CPDA‐1 whole blood with a platelet‐saving filter did not compromise hemostatic properties. We encourage development of a single bag CPDA‐1 whole blood collection set with in‐line platelet‐saving filter.

22 April 2020 in Transfusion
Verified
Journal Article
Open access
PDF file
CBChristopher Bjerkvig
Christopher Bjerkvig
JSJoar Sivertsen
Joar Sivertsen
HBHanne Braathen
Hanne Braathen
TLTurid Helen Felli Lunde
Turid Helen Felli Lunde
GSGeir Strandenes
Geir Strandenes
TATorunn Oveland Apelseth
Torunn Oveland Apelseth
BACKGROUND: Increasing numbers of emergency medical service agencies and hospitals are developing the capability to administer blood products to patients with hemorrhagic shock. Cold‐stored whole blood (WB) is the only single product available to prehospital providers who aim to deliver a balanced resuscitation strategy. However, there are no data on the safety and in vitro characteristics of prehospital stored WB. This study aimed to describe the effects on in vitro quality of storing WB at remote helicopter bases in thermal insulating containers.STUDY DESIGN AND METHODS: We conducted a two‐armed single‐center study. Twenty units (test) were stored in airtight thermal insulating containers, and 20 units (controls) were stored according to routine procedures in the Haukeland University Hospital Blood Bank. Storage conditions were continuously monitored during emergency medical services missions and throughout remote and blood bank storage. Hematologic and metabolic variables, viscoelastic properties, and platelet (PLT) aggregation were measured on Days 1, 8, 14, and 21.RESULTS: Storage conditions complied with the EU guidelines throughout remote and in‐hospital storage for 21 days. There were no significant differences in PLT aggregation, viscoelastic properties, and hematology variables between the two groups. Minor significantly lower pH, glucose, and base excess and higher lactate were observed after storage in airtight containers.CONCLUSION: Forward cold storage of WB is safe and complies with EU standards. No difference is observed in hemostatic properties. Minor differences in metabolic variables may be related to the anaerobic conditions within the thermal box.

1 June 2018 in Journal of Trauma and Acute Care Surgery
Verified
Journal Article
Closed access
JSJoar Sivertsen
Joar Sivertsen
HBHanne Braathen
Hanne Braathen
TLTurid Helen F. Msc Lunde
Turid Helen F. Msc Lunde
PSPhilip C. Spinella
Philip C. Spinella
WDWarren Dorlac
Warren Dorlac
EKEinar K. Kristoffersen
Einar K. Kristoffersen
BACKGROUND: Damage control resuscitation principles advocate the use of blood to treat traumatic hemorrhage. Hemorrhage is a leading cause of preventable death on the battlefield, but making blood components available far forward presents logistical challenges due to shelf life and storage requirements. Whole blood simplifies logistics and enables collection in the field but can cause leukocyte-related transfusion reactions. A field-adapted leukoreduction system must be fast and safe, and storage of whole blood should preserve hemostatic function. METHODS: Blood was collected using Imuflex WB-SP and leukoreduced at 0, 150, or 300 mm Hg. Additional bags were stored at 4°C for 21 days unagitated, mixed daily, agitated or head-over-heel rotated, at 22°C for 3 days, or 32°C for 2 hours. Hematology, coagulation, CD62P/CD42b, thromboelastography (TEG)/thromboelastometry (ROTEM), and Multiplate was performed. RESULTS: Filtration time was 35 ± 1, 14 ± 0, and 9 ± 0 minutes at 0, 150, and 300 mm Hg, respectively. One of 10 units at 150 mm Hg and 4 of 11 at 300 mm Hg had residual whole blood cells greater than 5.0 × 106 per unit. One of 11 at 300 mm Hg had platelet recovery of less than 80%. Hemolysis was less than 0.2%. Filtration decreased thromboelastography/thromboelastometry and Multiplate aggregation response. Stored at 4°C, α and MA/MCF moderately decreased regardless of mixing. Significant loss of aggregation response and increased CD62P expression was seen by Day 10. By Day 3, storage at 22°C caused loss of most aggregation. Two-hour storage at 32°C did not significantly affect hemostatic capacity. CONCLUSION: Forced filtration reduced leukoreduction time, but increased residual whole blood cells reduced hemostatic function. Aggregation response deteriorated early in storage, while viscoelastic assays decreased more gradually. Mixing showed no benefits. LEVEL OF EVIDENCE: Diagnostic study, level IV.

16 July 2021 in Transfusion
Verified
Journal Article
Open access
PDF file
KHKristin Gjerde Hagen
Kristin Gjerde Hagen
GSGeir Strandenes
Geir Strandenes
EKEinar Klæboe Kristoffersen
Einar Klæboe Kristoffersen
HBHanne Braathen
Hanne Braathen
JSJoar Sivertsen
Joar Sivertsen
TATorunn Oveland Apelseth
Torunn Oveland Apelseth
Background: Civilian and military guidelines recommend early balanced transfusion to patients with life‐threatening bleeding. Low titer group O whole blood was introduced as the primary blood product for resuscitation of massive hemorrhage at Haukeland University Hospital, Bergen, Norway, in December 2017. In this report, we describe the whole blood program and present results from the first years of routine use.Study design and methods: Patients who received whole blood from December 2017 to April 2020 were included in our quality registry for massive transfusions. Post‐transfusion blood samples were collected to analyze isohemagglutinin (anti‐A/‐B) and hemolysis markers. Administration of other blood products, transfusion reactions, and patient survival (days 1 and 30) were recorded. User experiences were surveyed for both clinical and laboratory staff.Results: Two hundred and five patients (64% male and 36% female) received 836 units in 226 transfusion episodes. Patients received a mean of 3.7 units (range 1–35) in each transfusion episode. The main indications for transfusion were trauma (26%), gastrointestinal (22%), cardiothoracic/vascular (18%), surgical (18%), obstetric (11%), and medical (5%) bleeding. There was no difference in survival between patients with blood type O when compared with non‐group O. Haptoglobin level was lower in the transfusion episodes for non‐O group patients, however no clinical hemolysis was reported. No patients had conclusive transfusion‐associated adverse events. Both clinical and laboratory staff preferred whole blood to component therapy for massive transfusion.Discussion: The experience from Haukeland University Hospital indicates that whole blood is feasible, safe, and effective for in‐hospital treatment of bleeding.

24 June 2022 in Transfusion
Verified
Journal Article
Open access
JSJoar Sivertsen
Joar Sivertsen
THTor Hervig
Tor Hervig
GSGeir Strandenes
Geir Strandenes
EKEinar K. Kristoffersen
Einar K. Kristoffersen
HBHanne Braathen
Hanne Braathen
TATorunn O. Apelseth
Torunn O. Apelseth
Background: Blood products are frequently exposed to room temperature or higher for longer periods than permitted by policy. We aimed to investigate if this resulted in a measurable effect on common quality parameters and viscoelastic hemostatic function of cold stored CPDA‐1 whole blood.Study Design and Methods: 450 ml of whole blood from 16 O Rh(D) positive donors was collected in 63 ml of CPDA‐1 and stored cold. Eights bags were exposed to five weekly 4‐h long transient temperature changes to 28°C. Eight bags were stored continuously at 4°C as a control. Samples were collected at baseline on day 1, after the first cycle on day 1 and weekly before each subsequent cycle (day 7, 14, 21, 28 and 35). Hemolysis, hematological parameters, pH, glucose, lactate, potassium, thromboelastography, INR, APTT, fibrinogen, and factor VIII were measured.Results: CPDA‐1 whole blood repeatedly exposed to 28°C did not show reduced quality compared to the control group on day 35. Two units in the test group had hemolysis of 1.1% and 1.2%, and two in the control group hemolysis of 0.8%. Remaining thromboelastography clot strength (MA) on day 35 was 51.7 mm (44.8, 58.6) in the test group and 46.1 (41.6, 50.6) in the control group (p = .023). Platelet count was better preserved in the test group (166.7 [137.8, 195.6] vs. 117.8 [90.3, 145.2], p = .018). One sample in the test group was positive for Cutibacterium acnes on day 35 + 6.Conclusion: Hemolysis findings warrant further investigation. Other indicators of quality were not negatively affected.

16 July 2021 in Transfusion
Verified
Journal Article
Open access
PDF file
HBHanne Braathen
Hanne Braathen
JSJoar Sivertsen
Joar Sivertsen
TLTurid Helen Felli Lunde
Turid Helen Felli Lunde
GSGeir Strandenes
Geir Strandenes
PLPaul Christoffer Lindemann
Paul Christoffer Lindemann
TATorunn Oveland Apelseth
Torunn Oveland Apelseth
Background: Collection of non‐leukoreduced citrate‐phosphate‐dextrose‐adenine (CPDA‐1) whole blood is performed in walking blood banks. Blood collected under field conditions may have increased risk of bacterial contamination. This study was conducted to examine the effects of WBC reduction and storage temperature on growth of Escherichia coli (ATCC® 25922™) in CPDA‐1 whole blood.Methods: CPDA‐1 whole blood of 450 ml from 10 group O donors was inoculated with E. coli. Two hours after inoculation, the test bags were leukoreduced with a platelet‐sparing filter. The control bags remained unfiltered. Each whole blood bag was then split into three smaller bags for further storage at 2–6°C, 20–24°C, or 33–37°C. Bacterial growth was quantified immediately, 2 and 3 h after inoculation, on days 1, 3, 7, and 14 for all storage temperatures, and on days 21 and 35 for storage at 2–6°C.Results: Whole blood was inoculated with a median of 19.5 (range 12.0–32.0) colony‐forming units per ml (CFU/ml) E. coli. After leukoreduction, a median of 3.3 CFU/ml (range 0.0–33.3) E. coli remained. In the control arm, the WBCs phagocytized E. coli within 24 h at 20–24°C and 33–37°C in 9 of 10 bags. During storage at 2–6°C, a slow self‐sterilization occurred over time with and without leukoreduction.Conclusions: Storage at 20–24°C and 33–37°C for up to 24 h before leukoreduction reduces the risk of E. coli‐contamination in CPDA‐1 whole blood. Subsequent storage at 2–6°C will further reduce the growth of E. coli.