Marwa Zaatari

Marwa Zaatari

Auto-generated profile, based on publicly available information

Marwa Zaatari

Department of Civil, Architectural, and Environmental Engineering, University of Texas at Austin, Austin, TX, USA

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 February 2014 in HVAC&R Research
Verified
Journal Article
Closed access
MZMarwa Zaatari
Marwa Zaatari
ENElena Nirlo
Elena Nirlo
Daranee JareemitDaranee Jareemit
Daranee Jareemit
NCNeil Crain
Neil Crain
JSJelena Srebric
Jelena Srebric
JSJeffrey Siegel
Jeffrey Siegel
Identifying air pollutants that pose potential adverse health exposures in retail stores will facilitate exposure mitigation. Assessing the role of ventilation in mitigating this exposure is important to understand the energy implications of maintaining acceptable indoor air quality. In this work, we summarize results from 28 papers that report ventilation rates and/or pollutant concentrations in retail stores. These results were compared to available standards as well as data collected in non-retail environments. The findings of this review are: (1) half of the stores tested met/exceeded ASHRAE Standard 62.1-2010 (ASHRAE 2010a; or California Code of Regulations Title 24-2010) for ventilation; (2) PM2.5, acrolein, formaldehyde, and acetaldehyde exceeded their established, most conservative limits/reference exposures for a few of the stores tested in the United States, and outside the United States, researchers reported PM10, benzene, and trichloroethylene as additional pollutants found at concentrations that exceeded their limits; (3) alternative control methods would be more effective, and possibly more economical, than ventilation; (4) meeting or exceeding the ventilation requirements does not necessarily negate the presence of pollutants above their suggested limits; and (5) using disability-adjusted-life-year (DALY) as a metric of disease burden, two pollutants were identified as priority hazards in retail stores: PM2.5 and acrolein. Control strategies should focus on decreasing exposure of retail employees to these pollutants generated indoors or infiltrated from outdoors.

1 May 2016 in Building and Environment
Verified
Journal Article
Closed access
MZMarwa Zaatari
Marwa Zaatari
ANAtila Novoselac
Atila Novoselac
JSJeffrey Siegel
Jeffrey Siegel

2 July 2025 in Building and Environment
Verified
Journal Article
Open access
BJBenjamin Jones
Benjamin Jones
CIChristopher Iddon
Christopher Iddon
MZMarwa Zaatari
Marwa Zaatari
PWPawel Wargocki
Pawel Wargocki
RBRichard Bruns
Richard Bruns