14 August 2019 in Nature Communications
Fluorescence correlation spectroscopy (FCS), is a widely used tool routinely exploited for in vivo and in vitro applications. While FCS provides estimates of dynamical quantities, such as diffusion coefficients, it demands high signal to noise ratios and long time traces, typically in the minute range. In principle, the same information can be extracted from microseconds to seconds long time traces; however, an appropriate analysis method is missing. To overcome these limitations, we adapt novel tools inspired by Bayesian non-parametrics, which starts from the direct analysis of the observed photon counts. With this approach, we are able to analyze time traces, which are too short to be analyzed by existing methods, including FCS. Our new analysis extends the capability of single molecule fluorescence confocal microscopy approaches to probe processes several orders of magnitude faster and permits a reduction of photo-toxic effects on living samples induced by long periods of light exposure.
19 March 2019 in The Journal of Chemical Physics
One way to achieve spatial resolution using fluorescence imaging—and track single molecules—is to use wide-field illumination and collect measurements over multiple sensors (camera pixels). Here we propose another way that uses confocal measurements and a single sensor. Traditionally, confocal microscopy has been used to achieve high temporal resolution at the expense of spatial resolution. This is because it utilizes very few, and commonly just one, sensors to collect data. Yet confocal data encode spatial information. Here we show that non-uniformities in the shape of the confocal excitation volume can be exploited to achieve spatial resolution. To achieve this, we formulate a specialized hidden Markov model and adapt a forward filtering-backward sampling Markov chain Monte Carlo scheme to efficiently handle molecular motion within a symmetric confocal volume characteristically used in fluorescence correlation spectroscopy. Our method can be used for single confocal volume applications or incorporated into larger computational schemes for specialized, multi-confocal volume, optical setups.
30 January 2020 in Physical Review X
Fluorescence time traces are used to report on dynamical properties of molecules. The basic unit of information in these traces is the arrival time of individual photons, which carry instantaneous information from the molecule, from which they are emitted, to the detector on timescales as fast as microseconds. Thus, it is theoretically possible to monitor molecular dynamics at such timescales from traces containing only a sufficient number of photon arrivals. In practice, however, traces are stochastic and in order to deduce dynamical information through traditional means—such as fluorescence correlation spectroscopy (FCS) and related techniques—they are collected and temporally autocorrelated over several minutes. So far, it has been impossible to analyze dynamical properties of molecules on timescales approaching data acquisition without collecting long traces under the strong assumption of stationarity of the process under observation or assumptions required for the analytic derivation of a correlation function. To avoid these assumptions, we would otherwise need to estimate the instantaneous number of molecules emitting photons and their positions within the confocal volume. As the number of molecules in a typical experiment is unknown, this problem demands that we abandon the conventional analysis paradigm. Here, we exploit Bayesian nonparametrics that allow us to obtain, in a principled fashion, estimates of the same quantities as FCS but from the direct analysis of traces of photon arrivals that are significantly smaller in size, or total duration, than those required by FCS.
1 November 2020 in Cell Reports Physical Science
Lifetimes of chemical species are typically estimated by either fitting time-correlated single-photon counting (TCSPC) histograms or phasor analysis from time-resolved photon arrivals. While both methods yield lifetimes in a computationally efficient manner, their performance is limited by choices made on the number of distinct chemical species contributing photons. However, the number of species is encoded in the photon arrival times collected for each illuminated spot and need not be set by hand a priori. Here, we propose a direct photon-by-photon analysis of data drawn from pulsed excitation experiments to infer, simultaneously and self-consistently, the number of species and their associated lifetimes from a few thousand photons. We do so by leveraging new mathematical tools within the Bayesian nonparametric. We benchmark our method for both simulated and experimental data for 1–4 species.
7 July 2022 in ACS Photonics
Tracking single molecules continues to provide new insights into the fundamental rules governing biological function. Despite continued technical advances in fluorescent and non-fluorescent labeling as well as data analysis, direct observations of trajectories and interactions of multiple molecules in dense environments remain aspirational goals. While confocal methods provide a means to deduce dynamical parameters with high temporal resolution, such as diffusion coefficients, they do so at the expense of spatial resolution. Indeed, on account of a confocal volume’s symmetry, typically only distances from the center of the confocal spot can be deduced. Motivated by the need for true three dimensional high speed tracking in densely labeled environments, we propose a computational tool for tracking many fluorescent molecules traversing multiple, closely spaced, confocal measurement volumes providing independent observations. Various realizations of this multiple confocal volumes strategy have previously been used for long term, large area, tracking of one fluorescent molecule in three dimensions. What is more, we achieve tracking by directly using single photon arrival times to inform our likelihood and exploit Hamiltonian Monte Carlo to efficiently sample trajectories from our posterior within a Bayesian nonparametric paradigm. A nonparametric paradigm here is warranted as the number of molecules present are, themselves, a priori unknown. Taken together, we provide a computational framework to infer trajectories of multiple molecules at once, below the diffraction limit (the width of a confocal spot), in three dimensions at sub-millisecond or faster time scales.