Anna Yiyuan Huang

Anna Yiyuan Huang

Auto-generated profile, based on publicly available information

Anna Yiyuan Huang

Virginia Commonwealth University School of Medicine, Richmond VA USA

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2026 in JBJS Open Access
Verified
Journal Article
Open access
CPCasey J. Powell
Casey J. Powell
AHAnna Y. Huang
Anna Y. Huang
JCJohn Cyrus
John Cyrus
BCBenjamin P. Cassidy
Benjamin P. Cassidy
ACAndrew S. Cuthbert
Andrew S. Cuthbert
JVJennifer L. Vanderbeck
Jennifer L. Vanderbeck
Background: Orthopaedic personnel are routinely exposed to noise from saws, drills, and hammers that exceeds safety thresholds, placing them at significant risk of noise-induced hearing loss (NIHL). Despite this hazard, preventive measures remain infrequently used. This systematic review evaluates NIHL prevalence, intraoperative noise, and effectiveness of protective measures in operating rooms. Methods: Studies on the prevalence, risk, and prevention of NIHL in orthopaedic personnel published before July 21, 2025 were screened from PubMed/Medline, Ovid Embase, and CENTRAL (Cochrane). Thirty-four studies met the inclusion criteria. Results: NIHL was identified in 17% of participants, and 56 of 75 surgical instruments exceeded the National Institute for Occupational Safety and Health (NIOSH) A-weighted limits. Noise levels were consistently unsafe during total hip and knee arthroplasty, particularly when robotic-assisted. Custom hearing protection with interchangeable noise reduction filters reduced exposure while maintaining intraoperative communication, whereas surgical hood systems showed minimal benefit, and active noise-cancelling headphones had mixed results. Conclusions: Orthopaedic personnel are frequently exposed to noise levels exceeding safety thresholds, especially during robotic-assisted total knee arthroplasty, placing them at risk for NIHL. Evidence supports using custom hearing protection with communication-preserving filters, developing quieter surgical equipment, and implementing routine hearing assessments to improve long-term hearing outcomes. Level of Evidence: II.

5 March 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
AHAnna Yiyuan Huang
Anna Yiyuan Huang
MBMitchell Bernstein
Mitchell Bernstein
JBJames A. Blair
James A. Blair
SRSteffen Rosslenbroich
Steffen Rosslenbroich
JSJohn A. Scolaro
John A. Scolaro
GMGeoffrey S. Marecek
Geoffrey S. Marecek
BackgroundDistraction osteogenesis is the process by which tissue is created through gradual distraction at a regular rate and rhythm. It is commonly used for bone lengthening due to congenital limb differences, malunion, and bone defects. As the timing and complexity of this procedure are necessarily dependent on the length gained or transported, surgeons have utilized various healing indices to describe their results including bone healing index (BHI), lengthening index (LI), consolidation index (CI), and external fixation index (EFI). Accurate and consistent definitions are therefore needed to compare outcomes across studies to eliminate the variability in reporting these important indices. This review seeks to evaluate the current literature on the accuracy and consistency of how these indices are defined. MethodsStudies using the terms BHI, LI, CI, or EFI published prior to December 31, 2025 were searched and screened using the Pubmed/Medline and Web of Science databases. Separate searches were performed for each healing index; 62 articles reporting BHI, 41 for LI, 63 for CI, and 145 for EFI, met inclusion criteria.ResultsAcross the studies reporting on BHI, 29.0% did not explicitly define BHI and another 22.6% defined the parameter incorrectly, mostly confusing the term with EFI (78.6%). In 29.3% of the articles that included LI, a definition was not provided. Among the articles that provided an LI definition, 55.2% were incorrect. Of these, 68.8% mistakenly equate LI with EFI. For CI, 28.6% of articles mentioning the term did not provide a definition. When CI was defined, it was frequently described in terms more consistent with BHI (66.7%). 24.4% of CI definitions were incomplete and only 4.4% were complete and correct. Conversely, EFI was accurately described in 96.7% of its studies.ConclusionSignificant inconsistencies exist in the definitions for healing indices across studies on distraction osteogenesis. The use of the terms BHI, and LI remains inconsistent and inaccurate across studies. The use of CI is consistently and incorrectly used interchangeably with BHI. EFI definitions were consistent. This investigation demonstrates the lack of standardized healing indices and underscores the urgent need to establish a common measure for assessing healing.

1 July 2026 in Injury
Verified
Journal Article
Closed access
AHAnna Y. Huang
Anna Y. Huang
MBMitchell Bernstein
Mitchell Bernstein
JBJames A. Blair
James A. Blair
SRSteffen Rosslenbroich
Steffen Rosslenbroich
JSJohn Scolaro
John Scolaro
GMGeoffrey S. Marecek
Geoffrey S. Marecek