A novel traveling-wave-based fault-location algorithm for multi-terminal transmission lines is introduced in this paper. Existing traveling-wave fault-location methods that based on the data measured at line terminals lack reliability and accuracy because time synchronization is needed, which brings error. To solve this problem, the complex structure of multi-terminal power system is divided into several fault identification branches, current at the midpoint of each branched is measured, a novel fault-location algorithm is proposed, and the time synchronization error is eliminated. A line-based device is designed to measure the current at the midpoint of each branch. An accurate value of the traveling wave speed can be obtained by merely applying the data record in one measuring device. Thus, the fault-location accuracy is improved. The system model applied in this article comprises one transmission line and two tapped lines, and the proposed method applies to networks with more terminals. Performance of this method is tested by different cases by PSCAD. The hardware platform has been tested in Sichuan Province, China.
Fragility modeling and real-time risk assessment can be widely applied to evaluate and enhances the resilience of the power system to High-Impact and Low Probability events. In previous studies, fragility modeling generally targets extreme weather conditions other than thunderstorm. This paper proposes a fragility model to describe the relationship between the duration of a thunderstorm and the probability of lightning related trip-out. The duration of thunderstorms, which can usually be forecasted from the meteorological department, together with the fragility function expression can help a power company to predict the possibility of lightning related trip-out. Furthermore, this paper proposes a real-time risk assessment model that can dynamically adjust the risk value based on the update of the location, peak current, and subsequent stroke of real-time thunderstorm. A case study conducted on the lightning related trip-out data in Southwest China demonstrates that the average risk of transmission line trip-out in high risk group is about ten times that in low risk group. It clearly demonstrates that real-time risk assessment can efficiently distinguish the trip-out risks of different real-time thunderstorms.
13 May 2020 in IEEE Transactions on Electromagnetic Compatibility
Lightning performance evaluation is aimed at classifying transmission lines into different risk levels of thunderstorm-induced trip-out. Its applications range from better lightning protection guidance, arrester installation design, transmission line retrofits, and line corridor design. Previous studies fail to consider the real-time lightning intensity, which is an essential factor of lightning trip-out that must not be ignored. This article proposes a novel lightning performance evaluation model based on the idea that the tower, which has a record of lightning trip-out with weaker real-time lightning intensity, is more susceptible to trip out, which means low lightning performance. In order to quantify the lightning intensity, this article puts forward a new definition of lightning intensity which includes three kinds of real-time characteristics, that is the location, the current of lightning strike, and the number of times the lightning movement track crosses the transmission line. More specifically, with the rapid development of lightning location system, a novel Lightning Identification, Tracking, and Analysis algorithm is proposed to search lightning movement track based on a database of 17 million lightning records. When lightning trip-out happens, the lightning performance level is graded according to the real-time lightning intensity. By comparing the similarity of static characteristics, the lightning performance level is extended to the tower, which has no record of lightning trip-out. By comparison with the traditional model, the proposed model is closer to the actual situation and can significantly improve the accuracy of lightning performance evaluation, which is improved by 66.7%.