Yuriy Yurkevych

Yuriy Yurkevych

Auto-generated profile, based on publicly available information

Yuriy Yurkevych

Lviv Polytechnic National University

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 February 2024 in Production Engineering Archives
Verified
Journal Article
Open access
PDF file
KMKhrystyna Myroniuk
Khrystyna Myroniuk
YFYurii Furdas
Yurii Furdas
VZVasyl Zhelykh
Vasyl Zhelykh
YYYurii Yurkevych
Yurii Yurkevych
This scientific article delves into the intricacies of wind flow's impact on multi-storey buildings, presenting results from a series of experimental...

17 August 2020
Verified
Book Chapter
Closed access
PDF file
KMKhrystyna Myroniuk
Khrystyna Myroniuk
OVOrest Voznyak
Orest Voznyak
YYYuriy Yurkevych
Yuriy Yurkevych
BGBohdan Gulay
Bohdan Gulay



7 August 2022
Verified
Book Chapter
Closed access
PDF file
YFYurii Furdas
Yurii Furdas
YYYuriy Yurkevych
Yuriy Yurkevych
VZVasyl Zhelykh
Vasyl Zhelykh
Malgorzata UlewiczMalgorzata Ulewicz
Malgorzata Ulewicz

20 June 2023 in Theory and Building Practice
Verified
Journal Article
Closed access
OSOlena Savchenko
Olena Savchenko
YYYuriy Yurkevych
Yuriy Yurkevych
OVOrest Voznyak
Orest Voznyak
ZSZenon Savchenko
Zenon Savchenko
The analytic research was conducted for a residential building built according to a typical project in Lviv. As the research data showed, the requirements of the existing normative documents of Ukraine do not allow to significantly reduce the heat load on the heat source. Thus, the value of the maximum heat flow to the heating system decreased by 36%, and the maximum heat flow to the hot water supply system - by 7.7%, and the total maximum hourly heat consumption, respectively, decreased by 23%. In addition, studies have established that for such values of the thermal power of the heat source, a decrease in the temperature parameters of the heat carrier can lead to an increase in the consumption of the heat carrier to provide thermal energy to the house by almost 3 times. And this, in turn, for the same diameter of the pipeline, leads to an increase in specific pressure losses by more than 5 times, and, accordingly, to an increase in the power of circulation pumps, the consumption of electrical energy and the cost of these pumps. This means that at present, the transition of large systems of district heating system of Ukraine to low-temperature coolants is possible only during the reconstruction of heat networks.