Patrick Cohen

Patrick Cohen

Auto-generated profile, based on publicly available information

Patrick Cohen

Division of Laboratory Medicine, Diagnostic Department Geneva University Hospitals and Faculty of Medicine Geneva Switzerland

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 September 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
MSMichel MME SOULARD Soulard
Michel MME SOULARD Soulard
HKHela Ketatni
Hela Ketatni
CVClaire Visseaux
Claire Visseaux
PCPascale Croix
Pascale Croix
PCPatrick Cohen
Patrick Cohen
Background: In EDTA-induced pseudothrombopenia, citrate or MgSO4 are recommended for platelet counting. Pre-analytical conditions are poorly defined for tubes containing MgSO4 or citrate. In this study, we analyzed the impact of agitation of these tubes on platelet counts. Methods: K2EDTA, citrate, and MgSO4 tubes from 70 patients were gently agitated on a wheel rotating at 20 rpm. Platelets were analyzed on the Sysmex XN analyzer at different times, and the percentage of platelet deviation from T0 was assessed and compared with the desirable bias of the EFLM. Results: at 180 min in fluorescence, the relative variation of platelets after shaking is 1.17% for K2EDTA, −29.76% for citrate, and −33.18% for MgSO4, while for unshaken MgSO4 platelets the variation is −1.3%. The reduction in platelet numbers when citrate or MgSO4 tubes are shaken is linked to the appearance of platelet clusters. Conclusions: agitation of MgSO4 and especially citrate tubes led to a decrease in platelet counts due to the formation of platelet aggregates; on the other hand, platelet counts on EDTA are virtually stable. During transport, we recommend putting sodium citrate and MgSO4 tubes in an upright position and avoiding shaking them to avoid giving an erroneous platelet result.

15 November 2025 in International Journal of Laboratory Hematology
Verified
Journal Article
Open access
MSMichel MME SOULARD Soulard
Michel MME SOULARD Soulard
HKHela Ketatni
Hela Ketatni
PCPascale Croix
Pascale Croix
SWSoraya Wuilleme
Soraya Wuilleme
PCPatrick Cohen
Patrick Cohen
Introduction: We investigated the stability and accuracy of platelets with MgSO 4 and compared the results of blood counts between MgSO 4 and K2EDTA. Methods: Platelet stability as a function of time was assessed on the XN Sysmex analyzer by comparing the percentage deviation to the desirable bias of the EFLM. Accuracy was determined by calculating the LoQ of platelets corresponding to a CV of 10%. Results from 250 patients were compared between K2EDTA and MgSO 4 . Results: At 20°C, platelets were stable for 24 h in impedance, 10 h in fluorescence and at 4°C for 4 h in impedance, 2 h in fluorescence. This decrease is related to the formation of platelet aggregates. For platelets in fluorescence, LoQ is 4 × 10 9 /L using MgSO 4 . The results of the complete blood count did not differ between K2EDTA and MgSO 4 except for the MCV, for which the median relative bias (MRB) with respect to K2EDTA was −5.6%. For MgSO 4 platelets, the MRB is 2.9% in fluorescence and 11.9% in impedance. Conclusion: The use of MgSO 4 with the XN produces results comparable to those obtained with K2EDTA, except for those related to MCV and for impedance platelets.