Christian W. A. Pfirrmann

Christian W. A. Pfirrmann

Auto-generated profile, based on publicly available information

Christian W. A. Pfirrmann

Faculty of Medicine, University of Zurich, Zurich, Switzerland

Research Focus & Metrics

Academic Career Length

35Years (1992-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2001 in Spine
Verified
Journal Article
Closed access
CPChristian W. A. Pfirrmann
Christian W. A. Pfirrmann
AMAlexander Metzdorf
Alexander Metzdorf
MZMarco Zanetti
Marco Zanetti
JHJuerg Hodler
Juerg Hodler
NBNorbert Boos
Norbert Boos
A reliability study was conducted. To develop a classification system for lumbar disc degeneration based on routine magnetic resonance imaging, to investigate the applicability of a simple algorithm, and to assess the reliability of this classification system. A standardized nomenclature in the assessment of disc abnormalities is a prerequisite for a comparison of data from different investigations. The reliability of the assessment has a crucial influence on the validity of the data. Grading systems of disc degeneration based on state of the art magnetic resonance imaging and corresponding reproducibility studies currently are sparse. A grading system for lumbar disc degeneration was developed on the basis of the literature. An algorithm to assess the grading was developed and optimized by reviewing lumbar magnetic resonance examinations. The reliability of the algorithm in depicting intervertebral disc alterations was tested on the magnetic resonance images of 300 lumbar intervertebral discs in 60 patients (33 men and 27 women) with a mean age of 40 years (range, 10–83 years). All scans were analyzed independently by three observers. Intra- and interobserver reliabilities were assessed by calculating kappa statistics. There were 14 Grade I, 82 Grade II, 72 Grade III, 68 Grade IV, and 64 Grade V discs. The kappa coefficients for intra- and interobserver agreement were substantial to excellent: intraobserver (kappa range, 0.84–0.90) and interobserver (kappa range, 0.69–0.81). Complete agreement was obtained, on the average, in 83.8% of all the discs. A difference of one grade occurred in 15.9% and a difference of two or more grades in 1.3% of all the cases. Disc degeneration can be graded reliably on routine T2-weighted magnetic resonance images using the grading system and algorithm presented in this investigation.

1 January 2006 in The Knee
Verified
Journal Article
Closed access
PSPhilip B. Schoettle
Philip B. Schoettle
MZMarco Zanetti
Marco Zanetti
BSBurkart Seifert
Burkart Seifert
CPChristian W.A. Pfirrmann
Christian W.A. Pfirrmann
SFSandro F. Fucentese
Sandro F. Fucentese
JRJose Romero
Jose Romero

1 September 2006 in Radiology
Verified
Journal Article
Closed access
CPChristian W. A. Pfirrmann
Christian W. A. Pfirrmann
BMBernard Mengiardi
Bernard Mengiardi
CDClaudio Dora
Claudio Dora
FKFabian Kalberer
Fabian Kalberer
MZMarco Zanetti
Marco Zanetti
JHJuerg Hodler
Juerg Hodler
To retrospectively characterize magnetic resonance (MR) arthrographic findings in patients with cam femoroacetabular impingement (FAI) and in those with pincer FAI. Institutional review board approval and informed consent were not required. MR arthrographic studies obtained in 50 consecutive patients (30 men, 20 women; mean age, 28.8 years) with FAI were analyzed for labral abnormalities, cartilage lesions, and osseous abnormalities of the acetabular rim. The nonspherical shape of the femoral head at the head-neck junction was measured in eight positions around the femoral head and neck and used to calculate the alpha angle. Acetabular depth was measured. Surgical diagnosis served as the reference standard. The Wilcoxon rank sum test was used for statistical analysis. At surgery, hips in 33 patients were classified as having cam FAI and hips in 17 patients were classified as having pincer FAI. In both groups, the mean age of patients was 28.8 years. There were significantly more men (n = 27) with cam FAI and more women (n = 14) with pincer FAI. The alpha angle was significantly larger in patients with cam FAI at the anterior and anterosuperior positions. The acetabulum was significantly deeper in patients with pincer FAI than in patients with cam FAI. Cartilage lesions at the anterosuperior and superior positions were significantly larger in patients with cam FAI than in patients with pincer FAI. Cartilage lesions at the posteroinferior position were significantly larger and labral lesions at the posterior and posteroinferior positions were more pronounced in patients with pincer FAI than in patients with cam FAI. Osseous abnormalities were not significantly different between the groups. Osseous bump formation at the femoral neck was significantly more common in patients with cam FAI than in patients with pincer FAI. Characteristic MR arthrographic findings of cam FAI include large alpha angles and cartilage lesions at the anterosuperior position and osseous bump formation at the femoral neck; characteristic findings of pincer FAI include a deep acetabulum and posteroinferior cartilage lesions.

1 March 2000 in Journal of Bone and Joint Surgery
Verified
Journal Article
Closed access
BJBernhard Jost
Bernhard Jost
CPChristian W. A. Pfirrmann
Christian W. A. Pfirrmann
CGChristian Gerber
Christian Gerber
On concerning the advisability of rotator cuff repair in situations in which there may be a high probability of rerupture....

1 September 2000 in Radiology
Verified
Journal Article
Closed access
CPChristian W. A. Pfirrmann
Christian W. A. Pfirrmann
MZMarco Zanetti
Marco Zanetti
JRJosé Romero
José Romero
JHJuerg Hodler
Juerg Hodler
PURPOSE: To establish quantitative and qualitative magnetic resonance (MR) criteria for the diagnosis of trochlear dysplasia. MATERIALS AND METHODS: MR images were analyzed in 16 consecutive patients with and 23 without trochlear dysplasia. The standard of reference was a true lateral radiograph of the knee. Quantitative and qualitative MR criteria were assessed. RESULTS: In patients with trochlear dysplasia, the trochlear groove was significantly less deep than that in control subjects. The most accurate measurement was 3 cm above the femorotibial joint space (P < .001), where a trochlear depth of 3 mm or less had a sensitivity of 100% and a specificity of 96%. The ventral trochlear prominence between the supratrochlear femoral cortex and the most ventral point of the trochlear floor (midsagittal section) was always larger than 6.9 mm in dysplastic trochleae. A facet ratio of less than 2:5 (medial to lateral) 3 cm above joint space level had a sensitivity of 100% and a specificity of 96%. A nipplelike an...

1 February 2001 in Radiology
Verified
Journal Article
Closed access
DWDominik Weishaupt
Dominik Weishaupt
MZMarco Zanetti
Marco Zanetti
JHJuerg Hodler
Juerg Hodler
KMKan Min
Kan Min
BFBruno Fuchs
Bruno Fuchs
NBNorbert Boos
Norbert Boos
To investigate the predictive value of magnetic resonance (MR) imaging of abnormalities of the lumbar intervertebral disks, particularly with adjacent endplate changes, to predict symptomatic disk derangement, with discography as the standard. Fifty patients aged 28-50 years with chronic low back pain and without radicular leg pain underwent prospective clinical examination and sagittal T1- and T2-weighted and transverse T2-weighted MR imaging. Subsequently, patients underwent lumbar discography with a pain provocation test (116 disks). MR images were evaluated for disk degeneration, a high-signal-intensity zone, and endplate abnormalities. Results of pain provocation at discography were rated independently of the image findings as concordant or as nonconcordant or painless. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated to assess the clinical relevance of MR abnormalities. Normal disks on MR images were generally not painful at provocative discography (NPV, 98%). Disk degeneration (sensitivity, 98%; specificity, 59%; PPV, 63%) and a high-signal-intensity zone (sensitivity, 27%; specificity, 85%; PPV, 56%) were not helpful in the identification of symptomatic disk derangement. When only moderate and severe type I and type II endplate abnormalities were considered abnormal, all injected disks caused concordant pain with provocation (sensitivity, 38%; specificity, 100%; PPV, 100%). Moderate and severe endplate abnormalities appear be useful in the prediction of painful disk derangement in patients with symptomatic low back pain.