In this work version of inverse Monte Carlo method for determination of optical parameters of biological tissues is presented. This method determine such optical parameters as anisotropy factor (g), absorption coefficient (μa), scattering coefficient (μs) both these coefficients determine mean free path (ds) which use for Monte Carlo simulation method of radiative transfer. These parameters are determined by the step-by-step searching. We have released three methods ofthe optical parameters searching: simple, differential and approximation. Optical parameters are changed by a certain value-step. In the simple searching method step is fixed, in the differential searching method step decreases as we approach to "mistake zone". The differential searching method finds more accurate results for a less time. In the approximation searching method a transfer radiation function (of optical parameter) is approximated by a power polynomial and the optical parameters value is determined from equation. The approximation searching method uses the close value of transfer radiation rate, without the "mistake zone". Using square approximation searching method the optical parameters adipose tissue has determined. The anisotropy factor g is equal 0.876 the scattering and absorption coefficients are equal 19.81 cm-1 and 0.15 cm-1 respectively.
Measurements of the gravitational frequency shift of a hydrogen clock were carried out when it was moved between two points located at different orthometric heights when transmitting the signal simultaneously via radio cable and optical fiber. Based on the obtained values of the average relative difference frequency, that of orthometric heights was calculated depending on the positions of the transported quantum clocks, the average value of which is 43,08 m. The maximum error based on the outcome of four height determinations is 2,58 m and it is 6,3 % of the actual value of 41,26 m. From the analysis of the obtained results, it follows that the main factor affecting the accuracy of altitude definition by the chronometric leveling method is the systematic change in the frequency of the transported quantum clocks. The main contribution to the error budget is made by the RMSD of the transported quantum clocks, which is 1,73 ⸱ 10^(–15)
The investigation of the interference pattern that appears during the passage of a Gaussian beam through a Michelson interferometer was carried out. That allowed to find the length measurement error due to diffraction-limited divergence and wavefront curvature of the light beam.
Shifts of the interference fringes originating from the passage of Gaussian beam through a Michelson interferometer have been studied, that allowed finding error of the meter standard caused by diffraction divergence and wavefront curvature of the light beam. We were obtained dependence of the error on the crossection of the beam waist and its position in the reference arm of the interferometer.