28 July 2005 in Nuclear Fusion
1 April 2004 in Nuclear Fusion
Simultaneous fast ELM measurements using a reflectometer, interferometers, Dα intensity and a magnetic probe reveal the detailed characteristics of type I ELMs. From the phase signal of the reflectometer indicating the radial movement of the cut-off layer, four different phases in the ELM event, i.e. a precursor phase, collapse phase, recovery phase and a relaxation phase, were observed. In the collapse phase, the radial extent of the collapse of the density pedestal reached up to twice the pedestal width. A fast drop of the horizontal interferometer signal was observed, while the vertical interferometer on the high-field side edge plasma only exhibited a small and delayed reduction. These features of the plasma response due to ELMs might indicate a non-uniform collapse of the density pedestal in the poloidal direction, localized near the low-field side (LFS) midplane. Expelled particles from the LFS midplane were measured by using scrape-off layer Mach probes, and the heat flux to the divertor target was measured using a fast infrared TV camera. The time constant of the peak heat load was comparable to that of the enhancement of the plasma flow towards the divertor target. The normalized ELM energy loss by pedestal stored energy in JT-60U was found to be less than 10% of the pedestal stored energy. It shows weak dependence on the pedestal parameters such as electron collisionality, parallel ion loss time and the ratio of the pedestal density to the Greenwald density limit.
1 March 2002 in Review of Scientific Instruments
A three-channel heterodyne O-mode reflectometer system has been developed for density fluctuation measurements on the JT-60U tokamak. The system consists of one fixed channel with a frequency of 34 GHz and two selectable frequency channels with frequencies in the range of 34–40 and 48–50 GHz in order to measure the change of fluctuation amplitude, fluctuation coherence, and movement of the cutoff layer during the discharge. The reflectometer system has now become a standard diagnostic for density fluctuation measurements on JT-60U covering both core and edge plasma regions. The capabilities of the system are illustrated for three experimental cases: edge transport barriers in H-mode plasmas, internal transport barriers in reversed shear plasmas, and fast turbulence burst at the onset of multifaceted asymmetric radiation from the edge.
1 October 2003 in Nuclear Fusion
The edge plasma density at the high-field side (HFS) and low-field side (LFS) was measured using a FIR interferometer and an O-mode reflectometer simultaneously in order to study the asymmetry of collapse of the density pedestal by type I ELM. From fast time series analysis using the same digitizer system for the reflectometer, Dα intensity, interferometer and magnetic probe, experimental evidence for poloidal asymmetry of the collapse was clearly observed in JT-60U ELMy H-mode discharges for the first time. The collapse of the pedestal density is manifested as a fast inward displacement of the cutoff layer at the LFS, the increase of Dα intensity and large magnetic oscillations. No immediate response, however, was observed in the line-integrated density at the HFS of the plasma (FIR-U1). Instead, the signal showed a small reduction after a time delay of about L∥/Cs, which was attributed to the parallel flow from the inside to outside in order to fill the density gap as a result of localized particle expulsion from the LFS. Furthermore, no density increase in the HFS scrape-off layer (SOL) was observed during the horizontal plasma sweep experiments corresponding to particles expelled from the HFS midplane to the SOL directly, at the onset of density collapse and before the increase of Dα intensity. Together, these results indicate that the collapse of the density pedestal during type I ELMs is localized at the LFS midplane.
16 September 2004 in Plasma Physics and Controlled Fusion
23 April 2004 in Plasma Physics and Controlled Fusion