Xin Li

Xin Li

Auto-generated profile, based on publicly available information

Xin Li

Research Center for Planetary Science, College of Earth and Planetary Sciences, Chengdu University of Technology, Chengdu, 610059, China

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 September 2019 in Geostandards and Geoanalytical Research
Verified
Journal Article
Closed access
PDF file
YAYa‐Jun An
Ya‐Jun An
XLXin Li
Xin Li
ZZZhaofeng Zhang
Zhaofeng Zhang

27 May 2019 in Geostandards and Geoanalytical Research
Verified
Journal Article
Closed access
PDF file
FLFang Liu
Fang Liu
XLXin Li
Xin Li
YAYa J. An
Ya J. An
JLJie Li
Jie Li
ZZZhao F. Zhang
Zhao F. Zhang

17 October 2023 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Closed access
PDF file
FLFang Liu
Fang Liu
XLXin Li
Xin Li
HYHong Yang
Hong Yang
QPQingyao Peng
Qingyao Peng
JWJiaojiao Wu
Jiaojiao Wu
ZZZhaofeng Zhang
Zhaofeng Zhang
In this study, we present a high-precision technique for measuring Nd stable isotopes by thermal ionization mass spectrometry (TIMS). A single and efficient Nd separation procedure is adopted with above 99% recovery using the DGA resin (Eichrom, USA). A 145Nd–150Nd double spike (DS) was used to correct mass-dependent fractionation during column chemistry and mass spectrometry. Repeated analyses of the JNdi-1 standard yielded a total average δ146/144Nd of 0.001 ± 0.016‰ (2SD, N = 12), and a δ148/144Nd of −0.005 ± 0.045‰ (2SD, N = 12), respectively. The pure Nd standard, La Jolla, produced a δ146/144Nd of −0.210 ± 0.006‰ (2SE). The δ146/144Nd of twelve geological reference materials, including COQ-1, DNC-1a, AGV-1, AGV-2, BHVO-2, BCR-2, G-2, RGM-1, GSP-2, NOD-A-1, NOD-P-1, and SDC-1, were also reported. Among them, the δ146/144Nd of COQ-1 was first reported. Simultaneously, the radiogenic 143Nd/144Nd of reference materials could be calculated using a double spike deconvolution with a precision of ≤5 ppm (2SE), in agreement with published values within an analytical uncertainty measured by conventional methods. Nd isotope fractionation during column chromatography was investigated. The known JNdi-1 was eluted with DGA resin using HCl as a solute and was sequentially collected into 8 fractions. δ146/144Nd systematically increased from −0.110 ± 0.011‰ (2SE) of the first Nd cut to +0.334 ± 0.011‰ (2SE) of the tailing cut following the mass-dependent fractionation law, suggesting significant Nd isotope fractionation during column chemistry. This phenomenon contradicts previous observations that light isotopes are preferentially retained onto the resin. The technique established in this study can obtain stable and radiogenic Nd isotopic compositions simultaneously from a single aliquot using a double spike by TIMS, providing at least two-dimensional constrains to the source of a material.

28 January 2022 in Geostandards and Geoanalytical Research
Verified
Journal Article
Closed access
PDF file
FLFang Liu
Fang Liu
XLXin Li
Xin Li
ZZZhaofeng Zhang
Zhaofeng Zhang
JBJianghao Bai
Jianghao Bai
YAYajun An
Yajun An

30 October 2024 in Geostandards and Geoanalytical Research
Verified
Journal Article
Closed access
JWJiaojiao Wu
Jiaojiao Wu
YAYajun An
Yajun An
XLXin Li
Xin Li
FLFang Liu
Fang Liu
JXJianbing Xu
Jianbing Xu
ZZZhaofeng Zhang
Zhaofeng Zhang

18 August 2024 in Geostandards and Geoanalytical Research
Verified
Journal Article
Closed access
YAYajun An
Yajun An
XLXin Li
Xin Li
WLWenning Lu
Wenning Lu
JXJianbing Xu
Jianbing Xu
YXYongli Xue
Yongli Xue
ZZZhaofeng Zhang
Zhaofeng Zhang