Maegan N. Shields

Maegan N. Shields

Auto-generated profile, based on publicly available information

Maegan N. Shields

Division of Orthopaedic Surgery, Postgraduate Medical Education, University of Toronto, Toronto, ON, Canada

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 July 2017 in Arthroscopy Techniques
Verified
Journal Article
Open access
CCChristopher L. Camp
Christopher L. Camp
JSJoaquin Sanchez‐Sotelo
Joaquin Sanchez‐Sotelo
MSMaegan N. Shields
Maegan N. Shields
SOShawn W. O'DRiscoll
Shawn W. O'DRiscoll
Reconstruction of the lateral ulnar collateral ligament of the elbow is the primary treatment for recurrent symptomatic posterolateral rotatory instability. Although a number of lateral ulnar collateral ligament reconstruction techniques have been described, the docking technique has received general acceptance. In this technique, the graft is passed through a tunnel on the ulnar side and the 2 free limbs are docked into the humerus at the isometric point on the lateral condyle. Advantages of this method of reconstruction include reduced bone removal, decreased soft tissue damage, and precise control of graft tensioning. When precise surgical steps are followed, this technique can be performed in a reliable, efficient, and reproducible manner for patients with posterolateral rotatory instability of the elbow. Technique Video: video See video under supplementary data.

2 March 2022 in Journal of Bone and Joint Surgery
Verified
Journal Article
Closed access
SOShawn W. O’dRiscoll
Shawn W. O’dRiscoll
JLJorge Rojas Liévano
Jorge Rojas Liévano
MMMark E. Morrey
Mark E. Morrey
JSJoaquin Sanchez-Sotelo
Joaquin Sanchez-Sotelo
DSDave R. Shukla
Dave R. Shukla
MSMaegan N. Shields
Maegan N. Shields
Background: Continuous passive motion (CPM) has been used for decades, but we are not aware of any randomized controlled trials (RCTs) in which CPM has been compared with physical therapy (PT) for rehabilitation following release of elbow contracture. Methods: In this single-blinded, single-center RCT, we randomly assigned patients undergoing arthroscopic release of elbow contracture to a rehabilitation protocol involving either CPM or PT. The primary outcomes were the rate of recovery and the arc of elbow motion (range of motion) at 1 year. The rate of recovery was evaluated by measuring range of motion at 6 weeks and 3 months. The secondary outcomes included other range-of-motion-related outcomes, patient-reported outcome measures (PROMs), flexion strength and endurance, grip strength, and forearm circumference at multiple time points. Results: A total of 24 patients were assigned to receive CPM, and 27 were assigned to receive PT. At 1 year, CPM was superior to PT with regard to the range of motion, with an estimated treatment difference of 9° (95% confidence interval [CI], 3° to 16°; p = 0.007). Similarly, the use of CPM led to a greater range of motion at 6 weeks and 3 months than PT. The percentage of lost motion recovered at 1 year was higher in the CPM group (51%) than in the PT group (36%) (p = 0.01). The probability of restoring a functional range of motion at 1 year was 62% higher in the CPM group than in the PT group (risk ratio for functional range of motion, 1.62; 95% CI, 1.01 to 2.61; p = 0.04). PROM scores were similar in the 2 groups at all time points, except for a difference in the American Shoulder and Elbow Surgeons (ASES) elbow function subscale, in favor of CPM, at 6 weeks. The use of CPM decreased swelling and reduced the loss of flexion strength, flexion endurance, and grip strength on day 3, with no between-group differences thereafter. Conclusions: Among patients undergoing arthroscopic release of elbow contracture, those who received CPM obtained a faster recovery and a greater range of motion at 1 year, with a higher chance of restoration of functional elbow motion than those who underwent routine PT. Level of Evidence: Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.

1 March 2018 in Journal of Shoulder and Elbow Surgery
Verified
Journal Article
Closed access
JHJung-Taek Hwang
Jung-Taek Hwang
YKYoungbok Kim
Youngbok Kim
DBDaniel R. Bachman
Daniel R. Bachman
MSMaegan N. Shields
Maegan N. Shields
LBLawrence J. Berglund
Lawrence J. Berglund
SOShawn W. O'Driscoll
Shawn W. O'Driscoll

1 October 2023 in JBJS Open Access
Verified
Journal Article
Open access
PVPrushoth Vivekanantha
Prushoth Vivekanantha
ADAndre Dao
Andre Dao
LHLaurie A. Hiemstra
Laurie A. Hiemstra
MSMaegan Shields
Maegan Shields
ACAndrea Chan
Andrea Chan
ASAjay Shah
Ajay Shah
Background: Orthopaedic surgery suffers from gender disparity, and annual conferences are visible opportunities to quantify gender representation within a field. Therefore, the purpose of this manuscript was to investigate the prevalence of female speakers and moderators, and male-only panel sessions, at 10 major Orthopaedic Surgery meetings. Methods: Conference programs and details of faculty moderating or presenting in 10 Orthopaedic Surgery annual meetings in 2021 were retrieved. Conferences were selected with the aim of size and diversity in subspecialty topics and included American Association of Hip and Knee Surgeons, American Association for Hand Surgery, American Academy of Orthopaedic Surgeons, American Orthopaedic Society for Sports Medicine, Canadian Orthopaedic Association (COA), European Federation of National Associations of Orthopaedics and Traumatology, North American Spine Society, Orthopaedic Research Society (ORS), Orthopaedic Trauma Association, and Pediatric Orthopaedic Society of North America (POSNA). Primary outcomes included percentage of female chairs and speakers and percentage of male-only panels, while secondary outcomes included number of publications, number of citations, and H-indexes of faculty. Further subgroup comparisons were performed between male-only panels and non–male-only panels and female members and male members. Results: Of 207 included sessions, 121 (58.5%) were male-only panels and 150 (12.6%) of 1,188 faculty members were women. Conferences organized by the COA, ORS, and POSNA had higher percentages of female representation, while spine surgery and adult hip/knee reconstruction sessions had more than 70% male-only panels and fewer than 10% female members. There were no significant differences between male members and female members regarding years of practice; however, male members were more likely to hold the title of professor (p < 0.001). Male members and female members stratified by quartiles of publications, citations, and H-indexes, moderated or participated in similar numbers of sessions, indicating an absence of selection bias. Conclusions: There is a high prevalence of male-only panels (58.5%) and an overall lack of female representation (12.6%) in 10 major Orthopaedic Surgery meetings. Male members and female members from these conferences were found to have similar qualifications academically. Specific strategies such as the elimination of male-only panels, selecting diverse conference organizers, and forming conference equity, diversity, and inclusion committees can help achieve cultural change. Level of Evidence: Level V.

1 June 2017 in JSES Open Access
Verified
Journal Article
Open access
PDF file
JLJulia Lee
Julia Lee
MSMaegan N. Shields
Maegan N. Shields
SOShawn W. O'Driscoll
Shawn W. O'Driscoll
Open reduction–internal fixation of comminuted radial head fractures involving 4 or more pieces is associated with a high risk of failure. Such fractures are generally treated by excision or by radial head arthroplasty. However, replacement with a metal implant can change the biomechanics of the joint, especially if the normal shape and position are not re-created. These alterations can theoretically lead to excess joint wear and tear. As with any metal implant, there is also the risk of loosening or progressive arthritis. Van Riet R.P. Van Glabbeek F. Neale P.G. Bimmel R. Bortier H. Morrey B.F. et al. Anatomical considerations of the radius. Clin Anat. 2004; 17 : 564-569 http://dx.doi.org/10.1002/ca.10256 Crossref PubMed Scopus (48) Google Scholar Some radial head fractures that are deemed unfixable involve only a portion of the articular surface, leaving half or more of the head and neck and thus length of the proximal radius intact. Theoretically, a partial prosthetic replacement could be accurately aligned to remaining landmarks as a method to restore elbow anatomy and stability. The purpose of this report was to present the concept of a partial radial head replacement, including long-term results, in 2 patients. Case report Patient 1 A 20-year-old right-hand–dominant male roofer was referred to us 5 months after falling from a roof and sustaining a fracture-dislocation of the right elbow. He was initially treated nonoperatively for a comminuted radial head fracture but had difficulty with pronation and supination and underwent partial resection of the radial head at an outside facility. At the time of presentation, he complained of medial and lateral elbow pain with a sense of instability, snapping, and paresthesias in the ulnar nerve distribution. Physical examination at presentation showed range of motion of 25°-125° in extension-flexion, 60° in pronation, and 80° in supination. There was ulnar nerve subluxation and diffuse painful crepitus at the lateral aspect of the joint with passive range of motion. Radiographs revealed a partial radial head defect and a small amount of heterotopic bone in the collateral ligaments. Stress radiographs revealed 2-3 mm of medial opening and 3-5 mm of lateral opening with varus-valgus stress and a grossly positive posterolateral rotatory drawer test. Further computed tomography imaging revealed a 40% radial head loss (Fig. 1) with an anteromedial subtype 2 coronoid fracture nonunion. O'Driscoll S.W. Jupiter J.B. Cohen M.S. Ring D. McKee M.D. Difficult elbow fractures: pearls and pitfalls. Instr Course Lect. 2003; 52 : 113-134 PubMed Google Scholar Figure 1 (A) A 3-dimensional computed tomography (CT) reconstruction showing the initial radial head defect involving 40% of the articular surface. (B) A 3-dimensional CT reconstruction showing an anteromedial subtype 2 coronoid fracture. (C) Sagittal CT cut demonstrating coronoid deficiency. (Used with permission of Mayo Foundation for Medical Education and Research. All rights reserved.) View Large Image Figure Viewer Download Hi-res image Download (PPT) Owing to the patient's young age and the fact that he had compromise of the coronoid, the radial head, and both collateral ligaments, it was necessary to restore the radial head capacity for load bearing and stability. Because more than half of the radial head was still intact and symmetry had been demonstrated in the right and left elbows, it was reasoned that the mechanics could be accurately restored by using contralateral 3-dimensional (3D) radial head measurements to design a prosthesis that aligned corresponding landmarks to re-create the missing bone. Alolabi B. Studer A. Gray A. Ferreira L.M. King G.J. Johnson J.A. et al. Selecting the diameter of a radial head implant: an assessment of local landmarks. J Shoulder Elbow Surg. 2013; 22 : 1395-1399 http://dx.doi.org/10.1016/j.jse.2013.04.005 Abstract Full Text Full Text PDF PubMed Scopus (12) Google Scholar ,  Ten Berg P.W. Dobbe J.G. van Wolfswinkel G. Strackee S.D. Streekstra G.J. Validation of the contralateral side as reference for selecting radial head implant sizes. Surg Radiol Anat. 2016; 38 : 801-807 http://dx.doi.org/10.1007/s00276-016-1625-x Crossref PubMed Scopus (9) Google Scholar Computed tomography scans were performed of both elbows so that a patient-specific prosthesis corresponding to the missing articular segment could be custom-made based on the contralateral intact radial head. The prosthesis was made of cobalt-chrome with a titanium porous surface at the bone-implant interface for bone ingrowth. It also had screw holes for compression against the native bone and a spike on its distal surface so that it could be easily held in position by inserting the spike into the metaphyseal bone of the radial neck. Dual incisions were used with the Kocher approach laterally and a standard medial approach to the elbow medially. The ulnar nerve was decompressed in situ. The coronoid...