Open reduction–internal fixation of comminuted radial head fractures involving 4 or more pieces is associated with a high risk of failure. Such fractures are generally treated by excision or by radial head arthroplasty. However, replacement with a metal implant can change the biomechanics of the joint, especially if the normal shape and position are not re-created. These alterations can theoretically lead to excess joint wear and tear. As with any metal implant, there is also the risk of loosening or progressive arthritis.
8 Van Riet R.P. Van Glabbeek F. Neale P.G. Bimmel R. Bortier H. Morrey B.F. et al. Anatomical considerations of the radius.
Clin Anat. 2004; 17 : 564-569 http://dx.doi.org/10.1002/ca.10256 Crossref PubMed Scopus (48) Google Scholar
Some radial head fractures that are deemed unfixable involve only a portion of the articular surface, leaving half or more of the head and neck and thus length of the proximal radius intact. Theoretically, a partial prosthetic replacement could be accurately aligned to remaining landmarks as a method to restore elbow anatomy and stability. The purpose of this report was to present the concept of a partial radial head replacement, including long-term results, in 2 patients. Case report Patient 1 A 20-year-old right-hand–dominant male roofer was referred to us 5 months after falling from a roof and sustaining a fracture-dislocation of the right elbow. He was initially treated nonoperatively for a comminuted radial head fracture but had difficulty with pronation and supination and underwent partial resection of the radial head at an outside facility. At the time of presentation, he complained of medial and lateral elbow pain with a sense of instability, snapping, and paresthesias in the ulnar nerve distribution. Physical examination at presentation showed range of motion of 25°-125° in extension-flexion, 60° in pronation, and 80° in supination. There was ulnar nerve subluxation and diffuse painful crepitus at the lateral aspect of the joint with passive range of motion. Radiographs revealed a partial radial head defect and a small amount of heterotopic bone in the collateral ligaments. Stress radiographs revealed 2-3 mm of medial opening and 3-5 mm of lateral opening with varus-valgus stress and a grossly positive posterolateral rotatory drawer test. Further computed tomography imaging revealed a 40% radial head loss (Fig. 1) with an anteromedial subtype 2 coronoid fracture nonunion.
5 O'Driscoll S.W. Jupiter J.B. Cohen M.S. Ring D. McKee M.D. Difficult elbow fractures: pearls and pitfalls.
Instr Course Lect. 2003; 52 : 113-134 PubMed Google Scholar
Figure 1 (
A) A 3-dimensional computed tomography (CT) reconstruction showing the initial radial head defect involving 40% of the articular surface. (
B) A 3-dimensional CT reconstruction showing an anteromedial subtype 2 coronoid fracture. (
C) Sagittal CT cut demonstrating coronoid deficiency. (Used with permission of Mayo Foundation for Medical Education and Research. All rights reserved.) View Large Image Figure Viewer Download Hi-res image Download (PPT) Owing to the patient's young age and the fact that he had compromise of the coronoid, the radial head, and both collateral ligaments, it was necessary to restore the radial head capacity for load bearing and stability. Because more than half of the radial head was still intact and symmetry had been demonstrated in the right and left elbows, it was reasoned that the mechanics could be accurately restored by using contralateral 3-dimensional (3D) radial head measurements to design a prosthesis that aligned corresponding landmarks to re-create the missing bone.
1 Alolabi B. Studer A. Gray A. Ferreira L.M. King G.J. Johnson J.A. et al. Selecting the diameter of a radial head implant: an assessment of local landmarks.
J Shoulder Elbow Surg. 2013; 22 : 1395-1399 http://dx.doi.org/10.1016/j.jse.2013.04.005 Abstract Full Text Full Text PDF PubMed Scopus (12) Google Scholar
, 6 Ten Berg P.W. Dobbe J.G. van Wolfswinkel G. Strackee S.D. Streekstra G.J. Validation of the contralateral side as reference for selecting radial head implant sizes.
Surg Radiol Anat. 2016; 38 : 801-807 http://dx.doi.org/10.1007/s00276-016-1625-x Crossref PubMed Scopus (9) Google Scholar
Computed tomography scans were performed of both elbows so that a patient-specific prosthesis corresponding to the missing articular segment could be custom-made based on the contralateral intact radial head. The prosthesis was made of cobalt-chrome with a titanium porous surface at the bone-implant interface for bone ingrowth. It also had screw holes for compression against the native bone and a spike on its distal surface so that it could be easily held in position by inserting the spike into the metaphyseal bone of the radial neck. Dual incisions were used with the Kocher approach laterally and a standard medial approach to the elbow medially. The ulnar nerve was decompressed in situ. The coronoid...