15 September 2023 in Journal of the American Academy of Orthopaedic Surgeons
Introduction: To improve transparency between candidates and training programs, a preference signaling program (PSP) was implemented before the 2022 to 2023 orthopaedic surgery match. The PSP allows applicants to ‘signal’ up to 30 programs, informing the program of the applicant's particular interest in interviewing for their available position(s). This study reports the perspectives of orthopaedic surgery residency applicants and program directors (PDs) on the effects of preference signaling on the orthopaedic match. Methods: Electronic surveys were distributed to PDs and applicants. Results: Almost all programs participated in the PSP (90%), and most of the applicants (97.6%) used 25 to 30 of their allotted preference signals. Most of the applicants (67.2%) thought that their likelihood of obtaining an interview was improved at ‘signaled’ programs but decreased at programs without a ‘signal’ designation (85.3%). Both applicants and PDs considered preference signaling to be one of the three most important factors for interview selection, along with Step 2 CK score and letters of recommendation. The applicants did not think that their likelihood of matching would improve with fewer allotted signaling tokens (35.2%), and 55.2% of PDs believed 21 to 30 tokens were optimal. Conclusion: Preference signaling is highly regarded by applicants and PDs. Signaling a program will likely improve an applicant's chance to interview. The optimal number of signaling tokens remains unknown, although both groups favored a larger allotment of tokens than has been seen in other specialties. Universal guidelines and recommendations for applicants and PDs would improve the utility of preference signaling.
1 October 2023 in Journal of Orthopaedic Trauma
Objective: To report upon a series of patients who have experienced the backout of distal interlocking screws after retrograde femoral nailing with the DePuy Synthes RFN-AdvancedTM Retrograde Femoral Nailing System (DePuy Synthes, Raynham, MA, USA). Design: Retrospective Case Series Setting: Level 1 Trauma Center Patients: Twenty-seven skeletally-mature patients with femoral shaft or distal femur fractures who underwent operative fixation with the DePuy Synthes RFN-AdvancedTM Retrograde Femoral Nailing System (RFNA) with 8 patients subsequently experiencing backout of distal interlocking screws. Intervention: The study intervention included retrospective review of patients’ charts and radiographs. Main Outcome Measurement: The incidence rate of distal interlocking screw backout. Results: Thirty percent of patients experienced the backout of at least one distal interlocking screw (mean: 1.625) after undergoing retrograde femoral nailing with the RFN-AdvancedTM system. Thirteen total screws backed out postoperatively. Screw backout was identified an average of 61 days postoperatively (range: 30 – 139). All patients complained of implant prominence and pain along the medial or lateral aspect of the knee. Five patients elected to return to the operating room to remove the symptomatic implant. The oblique distal interlocking screws comprised 62% of screw backouts. Conclusions: Given the high incidence rate of this complication, the associated costs of reoperation, and patient discomfort, we believe a further investigation into this implant complication is warranted. Level of Evidence: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
6 March 2023 in European Journal of Trauma and Emergency Surgery
22 March 2021 in Arthroscopy, Sports Medicine, and Rehabilitation
Purpose: To assess the relationship of acetabular version with the length of the anterior and posterior labrum and to introduce a developed metric, the labral index, as a means of controlling for femoral head size when measuring labral length. Methods: One hundred forty‐eight patients who underwent hip arthroscopies for femoroacetabular impingement from October 2017 to October 2019 by a single hip surgeon were retrospectively reviewed. Magnetic resonance imaging arthrogram was used to measure central acetabular version (at the center of the femoral head) and cranial acetabular version (at the midpoint between the acetabular roof and center of the femoral head), as well as labral length at the anterior, posterior, and superolateral locations (3, 9, and 12 o’clock, respectively). Labral index was calculated by dividing anterior, posterior, and superolateral labral lengths by the radius of the femoral head. Pearson correlation analysis was used to assess the association between the 2 continuous variables. A priori alpha of 0.05 was established as the cutoff for significance. Results: Forty‐three patients (26 female, 17 male) with an average age of 34.2 ± 11.6 years were included in analysis. Increased central anteversion was significantly associated with a larger anterior labral length and index ( P = .023, r = 0.343 and .005, r = 0.415, respectively). Cranial anteversion weakly correlated with a significantly increased anterior labral index ( P = .047, r = 0.304) but not with larger anterior labral length ( P = .089, r = 0.262). No statistically significant association was present for central or cranial version with posterior or superolateral labral measurements. Lateral center edge angle did not correlate with labral size at any location. Conclusions: In patients undergoing hip arthroscopy for symptomatic femoroacetabular impingement, greater acetabular anteversion was significantly associated but weakly correlated with increased anterior labral length, whereas no association was found between posterior labral length and acetabular version. The labral index may be a useful metric to normalize labral length relative to the radius of the femoral head that warrants further investigation for its clinical utility in guiding labral reconstruction versus labral repair. Level of Evidence: Level IV, diagnostic case series.
2 December 2024 in Archives of orthopaedic and trauma surgery
1 January 2024 in JBJS Case Connector
Case: A 23-year-old right-hand dominant man presented with a high-velocity gunshot wound injury to the right thumb with severe soft-tissue damage, vascular injury, and large osseous defect of the right thumb metacarpal. The patient was successfully treated with metacarpophalangeal joint arthrodesis and metacarpal reconstruction using definitive external fixation, an intramedullary Kirschner wire, and use of the Masquelet bone grafting technique. Conclusion: The authors' treatment approach for a mangled thumb injury with definitive external fixation and utilization of the Masquelet technique resulted in restoration of a large osseous defect, avoidance of infection, and limited loss of mobility.